General Visual Inspection of Air Intake Cowl Aft Bulkhead [CFMI]
TASK 71-11-00-210-041-A
General Visual Inspection of Air Intake Cowl Aft Bulkhead
1. Reason for the Job
Refer to the MPD TASK: 711000-C1
GENERAL VISUAL INSPECTION OF AIR INTAKE COWL AFT BULKHEAD
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 71-11-00-941-059-A ** ON A/C NOT FOR ALL
Subtask 71-11-00-210-059-A ** ON A/C NOT FOR ALL
Subtask 71-11-00-410-057-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.02 06:31:54 UTC
General Visual Inspection of Air Intake Cowl Aft Bulkhead
1. Reason for the Job
Refer to the MPD TASK: 711000-C1
GENERAL VISUAL INSPECTION OF AIR INTAKE COWL AFT BULKHEAD
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | ACCESS PLATFORM 1M(3 FT) |
| No specific | AR | WARNING NOTICE(S) |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| FOR [1000EM1] (ENGINE-1) | |
| 437AL, 438AR | |
| FOR [1000EM2] (ENGINE-2) | |
| 447AL, 448AR | |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 71-13-00-010-040-A | Opening of the Fan Cowl Doors |
| TASK 71-13-00-410-040-A | Closing of the Fan Cowl Doors |
Subtask 71-11-00-941-059-A ** ON A/C NOT FOR ALL
A. Safety Precautions
(1) On the center pedestal, on the ENG panel 115VU:
(a) Put a WARNING NOTICE(S) to tell persons not to start the engine.
(2) Make sure that the engine 1(2) shutdown occurred not less than 5 minutes before you do this procedure.
(3) On the overhead maintenance panel 50VU:
(a) Make sure that the ON legend of the ENG/FADEC GND PWR/1(2) pushbutton switch is off.
(b) Put a WARNING NOTICE(S) to tell persons not to energize the FADEC 1(2).
Subtask 71-11-00-010-057-A ** ON A/C NOT FOR ALL (1) On the center pedestal, on the ENG panel 115VU:
(a) Put a WARNING NOTICE(S) to tell persons not to start the engine.
(2) Make sure that the engine 1(2) shutdown occurred not less than 5 minutes before you do this procedure.
(3) On the overhead maintenance panel 50VU:
(a) Make sure that the ON legend of the ENG/FADEC GND PWR/1(2) pushbutton switch is off.
(b) Put a WARNING NOTICE(S) to tell persons not to energize the FADEC 1(2).
B. Get Access
(1) Open the fan cowl doors (Ref. AMM TASK 71-13-00-010-040):
(a) FOR [1000EM1] (ENGINE-1)
437AL 438AR
(b) FOR [1000EM2] (ENGINE-2)
447AL 448AR
(2) Put the ACCESS PLATFORM 1M(3 FT) in position.
4. Procedure(1) Open the fan cowl doors (Ref. AMM TASK 71-13-00-010-040):
(a) FOR [1000EM1] (ENGINE-1)
437AL 438AR
(b) FOR [1000EM2] (ENGINE-2)
447AL 448AR
(2) Put the ACCESS PLATFORM 1M(3 FT) in position.
Subtask 71-11-00-210-059-A ** ON A/C NOT FOR ALL
A. Do a Visual Inspection of the Intake Cowl Aft Bulkhead
(1) Do a general visual inspection of the intake cowl aft bulkhead.
(2) Make sure that there are no signs of damage (delamination, scratches, cracks or dents).
(a) If you find damage, look for damage limits and do the applicable repair procedureNSRM 541000 .
5. Close-up(1) Do a general visual inspection of the intake cowl aft bulkhead.
(2) Make sure that there are no signs of damage (delamination, scratches, cracks or dents).
(a) If you find damage, look for damage limits and do the applicable repair procedure
Subtask 71-11-00-410-057-A ** ON A/C NOT FOR ALL
A. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Close the fan cowl doors (Ref. AMM TASK 71-13-00-410-040):
(a) FOR [1000EM1] (ENGINE-1)
437AL 438AR
(b) FOR [1000EM2] (ENGINE-2)
447AL 448AR
(3) Remove the access platform(s).
(4) Remove the WARNING NOTICE(S).
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Close the fan cowl doors (Ref. AMM TASK 71-13-00-410-040):
(a) FOR [1000EM1] (ENGINE-1)
437AL 438AR
(b) FOR [1000EM2] (ENGINE-2)
447AL 448AR
(3) Remove the access platform(s).
(4) Remove the WARNING NOTICE(S).
Intake Cowl Forward and Aft Bulkeads