W DOC AIRBUS | AMM A320F

Installation of the High Speed Tape (Nose Air Intake Hoisting Point Plug) [CFMI]


TASK 71-11-00-040-802-A
Installation of the High Speed Tape (Nose Air Intake Hoisting Point Plug)


WARNING: BE CAREFUL WHEN YOU DO WORK ON THE ENGINE PARTS AFTER THE ENGINE SHUTDOWN. USE APPLICABLE THERMAL GLOVES. THE ENGINE PARTS CAN STAY HOT FOR ONE HOUR AFTER SHUTDOWN AND CAN BURN YOU.
WARNING: WEAR APPLICABLE PERSONAL PROTECTIVE EQUIPMENT (PPE) WHEN YOU DO THIS TASK. BEFORE YOU USE PPE, READ, UNDERSTAND AND OBEY ALL INSTRUCTIONS FOR ITS USE. THESE INSTRUCTIONS INCLUDE INSTRUCTIONS FROM THE MANUFACTURER, YOUR EMPLOYER AND GOVERNMENT REGULATIONS. YOU CAN GET INJURED IF YOU DO NOT USE PPE. GET INSTRUCTIONS FROM YOUR EMPLOYER ON WHICH PPE IS NECESSARY.
WARNING: BE CAREFUL WHEN YOU USE CONSUMABLE MATERIALS. OBEY THE MATERIAL MANUFACTURER'S INSTRUCTIONS AND YOUR LOCAL REGULATIONS.
ZONE: 400
1. Reason for the Job
CDL 71-06
NAI HOISTING POINT PLUG
To remove the inlet cowl hoist point insert bolt(s) and install high speed tape after the insert bolt(s) has become damaged or missing.
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
1
ACCESS PLATFORM 1M (3 FT)-ADJUSTABLE
No specific
AR
WARNING NOTICE(S)
 B. Consumable Materials
REFERENCE
DESIGNATION
(Material No.05RAB9)
Adhesive Film Tape-- Aluminium Foil -
 C. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
400
POWER PLANT, NACELLES AND PYLONS
FOR [1000EM1] (ENGINE-1)
437AL, 438AR
FOR [1000EM2] (ENGINE-2)
447AL, 448AR
 D. Referenced Information
REFERENCE
DESIGNATION
TASK 71-13-00-010-040-A
Opening of the Fan Cowl Doors
TASK 71-13-00-410-040-A
Closing of the Fan Cowl Doors
SRM 517712
3. Job Set-up
Subtask 71-11-00-941-068-A ** ON A/C NOT FOR ALL
A. Safety Precautions
   (1) On the center pedestal, on ENG panel 115VU:
     (a) Put the WARNING NOTICE(S) in position to tell persons not to start the engine.
   (2) Make sure that the engine 1(2) shutdown occurred not less than five minutes before you do this procedure.
   (3) On overhead maintenance panel 50VU:
     (a) Make sure that the ON legend of the ENG/FADEC GND PWR/1(2) pushbutton switch is off.
     (b) Put the WARNING NOTICE(S) in position to tell persons not to energize FADEC 1(2).
Subtask 71-11-00-010-068-A ** ON A/C NOT FOR ALL
B. Get Access
   (1) Open the fan cowl doors (Ref. AMM TASK 71-13-00-010-040):
     (a) FOR [1000EM1] (ENGINE-1)
437AL 438AR
     (b) FOR [1000EM2] (ENGINE-2)
447AL 448AR
   (2) Put the ACCESS PLATFORM 1M (3 FT)-ADJUSTABLE in position.
4. Procedure
Subtask 71-11-00-420-061-A ** ON A/C NOT FOR ALL
A. Installation of the High Speed Tape
   (1) If the damaged insert bolt(s) are there, remove the bolt(s) from the hoist point(s) on the inlet cowl.
   (2) Cut Adhesive Film Tape-- Aluminium Foil - (Material No.05RAB9) to the correct dimensions to the opening of the inlet cowl hoist point(s) SRM 517712.
   (3) Apply the Adhesive Film Tape-- Aluminium Foil - (Material No.05RAB9) to the opening of the inlet cowl hoist point(s) SRM 517712.
   (4) Make the Adhesive Film Tape-- Aluminium Foil - (Material No.05RAB9) smooth on the mating surfaces of the inlet cowl. Remove the air pockets and push the edges of the Adhesive Film Tape-- Aluminium Foil - (Material No.05RAB9) tightly SRM 517712.
   (5) Make sure that the Adhesive Film Tape-- Aluminium Foil - (Material No.05RAB9) gives the same protection as the insert bolt(s).
5. Close-up
Subtask 71-11-00-410-065-A ** ON A/C NOT FOR ALL
A. Close Access
   (1) Make sure that the work area is clean and clear of tools and other items.
   (2) Close the fan cowl doors (Ref. AMM TASK 71-13-00-410-040):
     (a) FOR [1000EM1] (ENGINE-1)
437AL 438AR
     (b) FOR [1000EM2] (ENGINE-2)
447AL 448AR
   (3) Remove the access platform(s).
   (4) Remove the WARNING NOTICE(S).