Removal of the Anti-Ice Vent Panel [CFMI]
TASK 71-11-00-000-043-A
Removal of the Anti-Ice Vent Panel
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 71-11-00-941-074-A ** ON A/C NOT FOR ALL
Subtask 71-11-00-020-063-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.02 06:31:53 UTC
Removal of the Anti-Ice Vent Panel
WARNING:
BE CAREFUL WHEN YOU DO WORK ON THE ENGINE PARTS AFTER THE ENGINE SHUTDOWN. USE APPLICABLE THERMAL GLOVES. THE ENGINE PARTS CAN STAY HOT FOR ONE HOUR AFTER SHUTDOWN AND CAN BURN YOU.
ZONE: 400
1. Reason for the JobSelf explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 1 | ACCESS PLATFORM 1M(3 FT) |
| No specific | AR | WARNING NOTICE(S) |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 400 | POWER PLANT, NACELLES AND PYLONS |
| FOR [1000EM1] (ENGINE-1) | |
| 437AL, 438AR | |
| FOR [1000EM2] (ENGINE-2) | |
| 447AL, 448AR | |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 71-13-00-010-040-A | Opening of the Fan Cowl Doors |
Subtask 71-11-00-941-074-A ** ON A/C NOT FOR ALL
A. Safety Precautions
(1) On the center pedestal, on ENG control panel 115VU:
(a) Put a WARNING NOTICE(S) in position to tell persons not to start the engine.
(2) Make sure that the engine 1(2) shutdown occurred not less than five minutes before you do this procedure.
(3) On overhead maintenance panel 50VU:
(a) Make sure that the ON legend of the ENG/FADEC GND PWR/1(2) pushbutton switch is off.
(b) Put a WARNING NOTICE(S) in position to tell persons not to energize FADEC 1(2).
Subtask 71-11-00-010-070-A ** ON A/C NOT FOR ALL (1) On the center pedestal, on ENG control panel 115VU:
(a) Put a WARNING NOTICE(S) in position to tell persons not to start the engine.
(2) Make sure that the engine 1(2) shutdown occurred not less than five minutes before you do this procedure.
(3) On overhead maintenance panel 50VU:
(a) Make sure that the ON legend of the ENG/FADEC GND PWR/1(2) pushbutton switch is off.
(b) Put a WARNING NOTICE(S) in position to tell persons not to energize FADEC 1(2).
B. Get Access
(1) Open the fan cowl doors (Ref. AMM TASK 71-13-00-010-040):
(a) FOR [1000EM1] (ENGINE-1)
437AL, 438AR
(b) FOR [1000EM2] (ENGINE-2)
447AL, 448AR
(2) Put the ACCESS PLATFORM 1M(3 FT) in position.
4. Procedure(1) Open the fan cowl doors (Ref. AMM TASK 71-13-00-010-040):
(a) FOR [1000EM1] (ENGINE-1)
437AL, 438AR
(b) FOR [1000EM2] (ENGINE-2)
447AL, 448AR
(2) Put the ACCESS PLATFORM 1M(3 FT) in position.
Subtask 71-11-00-020-063-A ** ON A/C NOT FOR ALL
A. Removal of the Anti-Ice Vent Panel
(1) Remove the bolts (5) and (10) and the anti-ice vent panel.
(1) Remove the bolts (5) and (10) and the anti-ice vent panel.
Inlet-Cowl Anti-Ice Vent-Panel