Removal of the Intake Cowl Inner Barrel Panel Drain Tube Valves POST SB RA32071-129 [CFMI]
TASK 71-11-00-000-042-A
Removal of the Intake Cowl Inner Barrel Panel Drain Tube Valves POST SB RA32071-129
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 71-11-00-941-065-A ** ON A/C NOT FOR ALL
Subtask 71-11-00-020-059-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.02 06:31:54 UTC
Removal of the Intake Cowl Inner Barrel Panel Drain Tube Valves POST SB RA32071-129
WARNING:
BE CAREFUL WHEN YOU DO WORK ON THE ENGINE PARTS AFTER THE ENGINE SHUTDOWN. USE APPLICABLE THERMAL GLOVES. THE ENGINE PARTS CAN STAY HOT FOR ONE HOUR AFTER SHUTDOWN AND CAN BURN YOU.
1. Reason for the JobSelf explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | ACCESS PLATFORM 1M(3 FT) |
| No specific | AR | WARNING NOTICE(S) |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| FOR [1000EM1] (ENGINE-1) | |
| 437AL, 438AR | |
| FOR [1000EM2] (ENGINE-2) | |
| 447AL, 448AR | |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 71-13-00-010-040-A | Opening of the Fan Cowl Doors |
Subtask 71-11-00-941-065-A ** ON A/C NOT FOR ALL
A. Safety Precautions
(1) Make sure that the engine 1(2) shutdown occurred not less than 5 minutes before you do this procedure.
(2) On the center pedestal, on the ENG panel 115VU:
(a) Put a WARNING NOTICE(S) in position to tell persons not to start the engine 1(2).
(3) On the ENG section of the maintenance panel 50VU:
(a) Make sure that the ON legend of the ENG/FADEC GND PWR/1(2) pushbutton switch is off.
(b) Put a WARNING NOTICE(S) in position to tell persons not to energize the FADEC 1(2).
Subtask 71-11-00-010-064-A ** ON A/C NOT FOR ALL (1) Make sure that the engine 1(2) shutdown occurred not less than 5 minutes before you do this procedure.
(2) On the center pedestal, on the ENG panel 115VU:
(a) Put a WARNING NOTICE(S) in position to tell persons not to start the engine 1(2).
(3) On the ENG section of the maintenance panel 50VU:
(a) Make sure that the ON legend of the ENG/FADEC GND PWR/1(2) pushbutton switch is off.
(b) Put a WARNING NOTICE(S) in position to tell persons not to energize the FADEC 1(2).
B. Get Access
(1) Open the fan cowl doors (Ref. AMM TASK 71-13-00-010-040):
(a) FOR [1000EM1] (ENGINE-1)
437AL 438AR
(b) FOR [1000EM2] (ENGINE-2)
447AL 448AR.
(2) Put the ACCESS PLATFORM 1M(3 FT) in position.
(3) Remove the screws (5) that attach the anti-ice vent panel (10) to the inlet cowl outer barrel.
(4) Remove the anti-ice vent panel (10).
4. Procedure(1) Open the fan cowl doors (Ref. AMM TASK 71-13-00-010-040):
(a) FOR [1000EM1] (ENGINE-1)
437AL 438AR
(b) FOR [1000EM2] (ENGINE-2)
447AL 448AR.
(2) Put the ACCESS PLATFORM 1M(3 FT) in position.
(3) Remove the screws (5) that attach the anti-ice vent panel (10) to the inlet cowl outer barrel.
(4) Remove the anti-ice vent panel (10).
Subtask 71-11-00-020-059-A ** ON A/C NOT FOR ALL
A. Removal of the Drain Tube Valves
(1) Remove the tie bands (20) that attach the valves (15) to the drain tubes.
(2) Pull the valves (15) and remove them from the drain tubes. Discard the tie bands and valves.
(1) Remove the tie bands (20) that attach the valves (15) to the drain tubes.
(2) Pull the valves (15) and remove them from the drain tubes. Discard the tie bands and valves.
Intake Cowl Inner Barrel Panel Drain Tube Valves