SPOP 427 - Application of Penetrating Oils for Disassembly [PW11]
TASK 70-24-00-910-801-A
SPOP 427 - Application of Penetrating Oils for Disassembly
A. Consumable Materials
B. Work Zones and Access Panels
3. Job Set-up
Subtask 70-24-00-860-053-A ** ON A/C NOT FOR ALL
Subtask 70-24-00-911-050-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.02 06:31:41 UTC
SPOP 427 - Application of Penetrating Oils for Disassembly
WARNING:
BE CAREFUL WHEN YOU USE CONSUMABLE MATERIALS. OBEY THE MATERIAL MANUFACTURER'S INSTRUCTIONS AND YOUR LOCAL REGULATIONS.
ZONE: 400
1. Reason for the JobNOTE: Always obey the specific procedures and limits in the specific AMM maintenance tasks.
2. Job Set-up InformationA. Consumable Materials
| REFERENCE | DESIGNATION |
|---|---|
| (Material No.P03-007) | PMC 9534 penetrating oil |
| (Material No.P03-015) | PMC 9545 penetrating fluid |
| (Material No.P03-016) | PMC 9503 penetrating fluid |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 400 | POWER PLANT, NACELLES AND PYLONS |
Subtask 70-24-00-860-053-A ** ON A/C NOT FOR ALL
A. Not Applicable
4. ProcedureSubtask 70-24-00-911-050-A ** ON A/C NOT FOR ALL
A. SPOP 427 - Application of Penetrating Oils for Disassembly
(1) Apply one of these penetrating oils to the necessary areas:
(a) PMC 9534 penetrating oil (Material No.P03-007)
1 Marvel mystery oil
(b) PMC 9545 penetrating fluid (Material No.P03-015)
1 318 versatoil
2 LPS LST penetrant
3 Knock'er loose
4 Metal guard 500
5 Metal guard aerosol
(c) PMC 9503 penetrating fluid (Material No.P03-016)
1 Aerokroil
2 Kroil
(1) Apply one of these penetrating oils to the necessary areas:
(a) PMC 9534 penetrating oil (Material No.P03-007)
1 Marvel mystery oil
(b) PMC 9545 penetrating fluid (Material No.P03-015)
1 318 versatoil
2 LPS LST penetrant
3 Knock'er loose
4 Metal guard 500
5 Metal guard aerosol
(c) PMC 9503 penetrating fluid (Material No.P03-016)
1 Aerokroil
2 Kroil