Detailed Inspection of Outboard Double-Slotted Flap, Internal Support Fitting at Track 3, Including Attachment Bracket, Drive Bracket ...


TASK 57-53-00-210-002-A
Detailed Inspection of Outboard Double-Slotted Flap, Internal Support Fitting at Track 3, Including Attachment Bracket, Drive Bracket ...


WARNING: PUT THE SAFETY DEVICES AND THE WARNING NOTICES IN POSITION BEFORE YOU START A TASK ON OR NEAR:
  • THE FLIGHT CONTROLS
  • THE FLIGHT CONTROL SURFACES
  • THE LANDING GEAR AND THE RELATED DOORS
  • COMPONENTS THAT MOVE.
MOVEMENT OF COMPONENTS CAN KILL OR CAUSE INJURY TO PERSONS AND/OR CAN CAUSE DAMAGE TO THE EQUIPMENT.
WARNING: MAKE SURE THAT THE GROUND SAFETY-LOCKS ARE IN POSITION ON THE LANDING GEAR. THIS WILL PREVENT UNWANTED MOVEMENT OF THE LANDING GEAR, AND THUS POSSIBLE INJURY TO PERSONS AND DAMAGE TO THE AIRCRAFT AND/OR EQUIPMENT.
CAUTION: BE CAREFUL WHEN YOU DO MAINTENANCE TASKS ON THE WING TRAILING EDGE:
  • DO NOT CAUSE DAMAGE TO THE ELECTRICAL CABLE RACEWAYS.
  • DO NOT CAUSE DAMAGE TO THE ELECTRICAL CABLE INSTALLATIONS.
  • MAKE SURE THAT THE ELECTRICAL CABLES ARE INSTALLED CORRECTLY. INCORRECT INSTALLATION CAN CAUSE DAMAGE.
CAUTION: DO NOT APPLY TEMPORARY PROTECTION SYSTEM (TPS) ON THE INSPECTION AREA. IF YOU APPLY TPS ON THE INSPECTION AREA, YOU CAN CAUSE DAMAGE TO THE AIRCRAFT.
ZONE: 587
ZONE: 687
1. Reason for the Job
Refer to the MPD TASK: 575329-01
DETAILED INSPECTION OF OUTBOARD DOUBLE-SLOTTED FLAP, INTERNAL SUPPORT FITTING AT TRACK 3, INCLUDING ATTACHMENT BRACKET, DRIVE BRACKET AND ATTACHMENT STRUCTURE, INTERNAL AND EXTERNAL, LH/RH
Refer to the MPD TASK: 575329-03
DETAILED INSPECTION OF OUTBOARD DOUBLE-SLOTTED FLAP, INTERNAL SUPPORT FITTING AT TRACK 3 INCLUDING ATTACHMENT BRACKET, DRIVE BRACKET AND ATTACHMENT STRUCTURE, INTERNAL AND EXTERNAL, LH/RH
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
AR
ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE
No specific
AR
LIGHT SOURCE - SPARK-PROOF
No specific
AR
SAFETY BARRIER(S)
No specific
AR
SAFETY CLIP - CIRCUIT BREAKER
No specific
AR
WARNING NOTICE(S)
 B. Consumable Materials
REFERENCE
DESIGNATION
(Material No.08BAA9)
Non Aqueous Cleaner-General - -
(Material No.14SBA1)
Textile-Lint free Cotton -
 C. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
587
FLAP N° 2
687
FLAP N° 2
532AT, 532CB, 632AT, 632CB
587AB, 687AB
 D. Referenced Information
REFERENCE
DESIGNATION
TASK 27-50-00-866-008-A
Extension of the Flaps on the Ground
TASK 27-50-00-866-008-A-01
Extension of the Flaps/Slats on the Ground
TASK 27-50-00-866-009-A
Retraction of the Flaps on the Ground
TASK 27-50-00-866-009-A-01
Retraction of the Flaps/Slats on the Ground
TASK 51-78-00-916-001-A
Application of Temporary Protection System (TPS)
TASK 57-55-11-000-004-A
Removal of the Flap Track Fairings Nos. 2, 3 and 4
TASK 57-55-11-400-004-A
Installation of the Flap Track Fairings Nos. 2, 3 and 4
SRM 575300
(for corrective action)
3. Job Set-up
Subtask 57-53-00-941-082-A ** ON A/C NOT FOR ALL
A. Safety Precautions
   (1) Put a WARNING NOTICE(S) on the flap/slat control lever (panel 114VU) to tell persons not to operate the flaps.
   (2) As necessary, use the applicable SAFETY BARRIERS, specified by the operator's instructions and your local regulations.
Subtask 57-53-00-860-054-A ** ON A/C NOT FOR ALL
B. Aircraft Maintenance Configuration
WARNING: MAKE SURE THAT THE TRAVEL RANGES OF THE FLIGHT CONTROLS SURFACES ARE CLEAR. MOVEMENT OF FLIGHT CONTROLS CAN CAUSE INJURY TO PERSONS AND/OR DAMAGE TO EQUIPMENT.
   (1) Fully extend the flaps (Ref. AMM TASK 27-50-00-866-008).
   (2) Make sure that the 98D27803000000 LOCKING TOOL-FLAP SLAT LEVER,INT. POSITION is installed on the flap/slat control lever on the panel 114VU.
Subtask 57-53-00-865-111-A ** ON A/C NOT FOR ALL
C. Open, safety and tag this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
49VUFLIGHT CONTROLS/FLP/CTL AND MONG/SYS16CVB07
** ON A/C NOT FOR ALL
49VUFLIGHT CONTROLS/FLP/CTL AND MONG/SYS16CVB02
** ON A/C NOT FOR ALL
121VUFLIGHT CONTROLS/FLP/CTL AND/MONG/SYS28CVQ21
Subtask 57-53-00-010-076-A ** ON A/C NOT FOR ALL
D. Get Access
   (1) Put the ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE in position below the flap track 3 at zone 532(632).
   (2) Remove the applicable flap track fairings (Ref. AMM TASK 57-55-11-000-004):
   (3) Remove the applicable access panel in the bottom skin at track 3:
  • for the left wing, remove 587AB
  • for the right wing, remove 687AB.
   (4) Put the LIGHT SOURCE - SPARK-PROOF adjacent to the inspection area.
Subtask 57-53-00-010-076-B ** ON A/C NOT FOR ALL
D. Get Access
   (1) Put the ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE in position below the flap track 3 at zone 532(632).
   (2) Remove the applicable flap track fairings (Ref. AMM TASK 57-55-11-000-004):
   (3) Put the LIGHT SOURCE - SPARK-PROOF adjacent to the inspection area.
Subtask 57-53-00-110-080-A ** ON A/C NOT FOR ALL
E. Preparation for Inspection
CAUTION: BE CAREFUL WHEN YOU DO MAINTENANCE TASKS ON THE WING TRAILING EDGE:
  • DO NOT CAUSE DAMAGE TO THE ELECTRICAL CABLE RACEWAYS.
  • DO NOT CAUSE DAMAGE TO THE ELECTRICAL CABLE INSTALLATIONS.
  • MAKE SURE THAT THE ELECTRICAL CABLES ARE INSTALLED CORRECTLY. INCORRECT INSTALLATION CAN CAUSE DAMAGE.
   (1) Make sure that the inspection area is sufficiently clean to do the inspection of the area.
   (2) Use a clean Textile-Lint free Cotton - (Material No.14SBA1) , made moist with Non Aqueous Cleaner-General - - (Material No.08BAA9) to clean:
  • the support fitting
  • the attachment bracket
  • the attachment structure
  • the internal support structure.
   (3) Make sure that there is no TPS layer and if there is a TPS layer, remove it (Ref. AMM TASK 51-78-00-916-001).
4. Procedure
Subtask 57-53-00-210-071-A ** ON A/C NOT FOR ALL
A. Detailed Inspection of Outboard Double-Slotted Flap, Internal Support fitting at Track 3, Including Attachment Bracket, Drive Bracket and Attachment Structure, Internal and External, LH/RH
   (1) Do an inspection of the support fitting, the attachment bracket and the attachment structure. Make sure that:
  • there is no damage
  • there is no corrosion
  • there are no cracks or scores
  • the support fitting, attachment bracket and drive bracket are installed correctly
  • the surface protection is in the correct condition.
   (2) Do an inspection of the internal support structure where it can be seen. Make sure that:
  • there is no damage
  • there is no corrosion
  • there are no cracks or scores
  • the support fitting, attachment bracket and drive bracket are installed correctly
  • the surface protection is the correct condition.
NOTE: If necessary, refer to the SRM 575300 for the correct repair procedure.
5. Close-up
Subtask 57-53-00-410-075-A ** ON A/C NOT FOR ALL
A. Close Access
   (1) Remove the spark-proof lamp from the inspection area.
   (2) Install the applicable access panel in the bottom skin at track 3:
  • for the left wing, install 587AB
  • for the right wing, install 687AB.
   (3) Install the applicable flap track fairings (Ref. AMM TASK 57-55-11-400-004):
   (4) Make sure that the work area is clean and clear of tools and other items.
Subtask 57-53-00-410-075-B ** ON A/C NOT FOR ALL
A. Close Access
   (1) Remove the spark-proof lamp from the inspection area.
   (2) Install the applicable flap track fairings (Ref. AMM TASK 57-55-11-400-004):
   (3) Make sure that the work area is clean and clear of tools and other items.
Subtask 57-53-00-865-112-A ** ON A/C NOT FOR ALL
B. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
49VUFLIGHT CONTROLS/FLP/CTL AND MONG/SYS16CVB07
** ON A/C NOT FOR ALL
49VUFLIGHT CONTROLS/FLP/CTL AND MONG/SYS16CVB02
** ON A/C NOT FOR ALL
121VUFLIGHT CONTROLS/FLP/CTL AND/MONG/SYS28CVQ21
Subtask 57-53-00-860-055-A ** ON A/C NOT FOR ALL
C. Aircraft Maintenance Configuration
   (1) Fully retract the flaps (Ref. AMM TASK 27-50-00-866-009).
Subtask 57-53-00-942-079-A ** ON A/C NOT FOR ALL
D. Removal of Equipment
   (1) Remove the WARNING NOTICE(S).
   (2) Remove the safety barriers.
   (3) Remove the access platform(s).
   (4) Remove the ground support and maintenance equipment, the special and standard tools and all other items.