Detailed Inspection of Inboard Double-Slotted Flap, Attachment Bracket of Pylon Aft Fairing, Including Surrounding Skin, LH/RH
TASK 57-52-00-210-004-A
Detailed Inspection of Inboard Double-Slotted Flap, Attachment Bracket of Pylon Aft Fairing, Including Surrounding Skin, LH/RH
Refer to the MPD TASK: 575229-01
DETAILED INSPECTION OF INBOARD DOUBLE-SLOTTED FLAP, ATTACHMENT BRACKET OF PYLON AFT FAIRING, INCLUDING SURROUNDING SKIN, LH/RH
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 57-52-00-941-073-A ** ON A/C NOT FOR ALL
Subtask 57-52-00-410-073-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.02 06:31:17 UTC
Detailed Inspection of Inboard Double-Slotted Flap, Attachment Bracket of Pylon Aft Fairing, Including Surrounding Skin, LH/RH
WARNING:
PUT THE SAFETY DEVICES AND THE WARNING NOTICES IN POSITION BEFORE YOU START A TASK ON OR NEAR:
- THE FLIGHT CONTROLS
- THE FLIGHT CONTROL SURFACES
- THE LANDING GEAR AND THE RELATED DOORS
- COMPONENTS THAT MOVE.
WARNING:
MAKE SURE THAT THE GROUND SAFETY-LOCKS ARE IN POSITION ON THE LANDING GEAR. THIS WILL PREVENT UNWANTED MOVEMENT OF THE LANDING GEAR, AND THUS POSSIBLE INJURY TO PERSONS AND DAMAGE TO THE AIRCRAFT AND/OR EQUIPMENT.
CAUTION:
BE CAREFUL WHEN YOU DO MAINTENANCE TASKS ON THE WING TRAILING EDGE:
1. Reason for the Job- DO NOT CAUSE DAMAGE TO THE ELECTRICAL CABLE RACEWAYS.
- DO NOT CAUSE DAMAGE TO THE ELECTRICAL CABLE INSTALLATIONS.
- MAKE SURE THAT THE ELECTRICAL CABLES ARE INSTALLED CORRECTLY. INCORRECT INSTALLATION CAN CAUSE DAMAGE.
Refer to the MPD TASK: 575229-01
DETAILED INSPECTION OF INBOARD DOUBLE-SLOTTED FLAP, ATTACHMENT BRACKET OF PYLON AFT FAIRING, INCLUDING SURROUNDING SKIN, LH/RH
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | ACCESS PLATFORM 5M (16 FT)- ADJUSTABLE |
| No specific | AR | LIGHT SOURCE - SPARK-PROOF |
| No specific | AR | SAFETY BARRIER(S) |
| No specific | AR | SAFETY CLIP - CIRCUIT BREAKER |
| No specific | AR | WARNING NOTICE(S) |
| 98D27803000000 | 1 | LOCKING TOOL-FLAP SLAT LEVER,INT. POSITION |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 581 | FLAP N° 1 |
| 681 | FLAP N° 1 |
| 475AL, 485AR | |
| 477AL, 487AR |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 54-53-11-000-002-A | Removal of the Pylon-to-Wing Access Panels |
| TASK 54-53-11-000-002-B | Removal of the Pylon-to-Wing Access Panels |
| TASK 54-53-11-000-804-A | Removal of the Pylon-to-Wing Access Panels and Doors |
| TASK 54-53-11-400-002-A | Installation of the Pylon-to-Wing Access Panels |
| TASK 54-53-11-400-002-B | Installation of the Pylon-to-Wing Access Panels |
| TASK 54-53-11-400-804-A | Installation of the Pylon-to-Wing Access Panels and Doors |
| SRM 575200 | (for corrective action) |
Subtask 57-52-00-941-073-A ** ON A/C NOT FOR ALL
A. Safety Precautions
(1) Put a WARNING NOTICE(S) on the flap/slat control lever (panel 114VU) to tell persons not to operate the flaps.
(2) As necessary, use the applicable SAFETY BARRIERS, specified by the operator's instructions and your local regulations.
Subtask 57-52-00-860-061-A ** ON A/C NOT FOR ALL (1) Put a WARNING NOTICE(S) on the flap/slat control lever (panel 114VU) to tell persons not to operate the flaps.
(2) As necessary, use the applicable SAFETY BARRIERS, specified by the operator's instructions and your local regulations.
B. Aircraft Maintenance Configuration
(1) Install the 98D27803000000 LOCKING TOOL-FLAP SLAT LEVER,INT. POSITION on the flap/slat control lever on the panel 114VU.
Subtask 57-52-00-865-095-A ** ON A/C NOT FOR ALL (1) Install the 98D27803000000 LOCKING TOOL-FLAP SLAT LEVER,INT. POSITION on the flap/slat control lever on the panel 114VU.
C. Open, safety and tag this(these) circuit breaker(s):
Subtask 57-52-00-010-071-A ** ON A/C NOT FOR ALL | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 49VU | FLIGHT CONTROLS/FLP/CTL AND MONG/SYS1 | 6CV | B07 |
| ** ON A/C NOT FOR ALL | |||
| 49VU | FLIGHT CONTROLS/FLP/CTL AND MONG/SYS1 | 6CV | B02 |
| ** ON A/C NOT FOR ALL | |||
| 121VU | FLIGHT CONTROLS/FLP/CTL AND/MONG/SYS2 | 8CV | Q21 |
D. Get Access
(1) Put the ACCESS PLATFORM 5M (16 FT)- ADJUSTABLE in position below the pylon at zone 470(480).
(2) Remove the applicable access panel (Ref. AMM TASK 54-53-11-000-002):
(3) Put the LIGHT SOURCE - SPARK-PROOF adjacent to the inspection area.
Subtask 57-52-00-010-071-C ** ON A/C NOT FOR ALL (1) Put the ACCESS PLATFORM 5M (16 FT)- ADJUSTABLE in position below the pylon at zone 470(480).
(2) Remove the applicable access panel (Ref. AMM TASK 54-53-11-000-002):
(3) Put the LIGHT SOURCE - SPARK-PROOF adjacent to the inspection area.
D. Get Access
(1) Put the ACCESS PLATFORM 5M (16 FT)- ADJUSTABLE in position below the pylon at zone 470(480).
(2) Remove the applicable access panel (Ref. AMM TASK 54-53-11-000-804):
(3) Put the LIGHT SOURCE - SPARK-PROOF adjacent to the inspection area.
4. Procedure(1) Put the ACCESS PLATFORM 5M (16 FT)- ADJUSTABLE in position below the pylon at zone 470(480).
(2) Remove the applicable access panel (Ref. AMM TASK 54-53-11-000-804):
(3) Put the LIGHT SOURCE - SPARK-PROOF adjacent to the inspection area.
CAUTION:
BE CAREFUL WHEN YOU DO MAINTENANCE TASKS ON THE WING TRAILING EDGE:
Subtask 57-52-00-210-062-A ** ON A/C NOT FOR ALL - DO NOT CAUSE DAMAGE TO THE ELECTRICAL CABLE RACEWAYS.
- DO NOT CAUSE DAMAGE TO THE ELECTRICAL CABLE INSTALLATIONS.
- MAKE SURE THAT THE ELECTRICAL CABLES ARE INSTALLED CORRECTLY. INCORRECT INSTALLATION CAN CAUSE DAMAGE.
A. Detailed Inspection of Inboard Double Slotted Flap, Attachment Bracket of Pylon Aft Fairing Including Surrounding Skin, LH/RH
(1) Do an inspection of the attachment bracket and the surrounding skin. Make sure that:
5. Close-up(1) Do an inspection of the attachment bracket and the surrounding skin. Make sure that:
- there is no damage
- there is no corrosion
- there are no cracks or scores
- the surface protection is in the correct condition.
- there is no damage
- there is no corrosion
- it is installed correctly
NOTE: If necessary, refer to the SRM 575200 for the correct repair procedure.
Subtask 57-52-00-410-073-A ** ON A/C NOT FOR ALL
A. Close Access
(1) Remove the spark-proof lamp from the inspection area.
(2) Make sure that the work area is clean and clear of tools and other items.
(3) Install the applicable access panel (Ref. AMM TASK 54-53-11-400-002):
Subtask 57-52-00-410-073-C ** ON A/C NOT FOR ALL (1) Remove the spark-proof lamp from the inspection area.
(2) Make sure that the work area is clean and clear of tools and other items.
(3) Install the applicable access panel (Ref. AMM TASK 54-53-11-400-002):
A. Close Access
(1) Remove the spark-proof lamp from the inspection area.
(2) Make sure that the work area is clean and clear of tools and other items.
(3) Install the applicable access panel (Ref. AMM TASK 54-53-11-400-804):
Subtask 57-52-00-865-096-A ** ON A/C NOT FOR ALL (1) Remove the spark-proof lamp from the inspection area.
(2) Make sure that the work area is clean and clear of tools and other items.
(3) Install the applicable access panel (Ref. AMM TASK 54-53-11-400-804):
B. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
Subtask 57-52-00-860-062-A ** ON A/C NOT FOR ALL | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 49VU | FLIGHT CONTROLS/FLP/CTL AND MONG/SYS1 | 6CV | B07 |
| ** ON A/C NOT FOR ALL | |||
| 49VU | FLIGHT CONTROLS/FLP/CTL AND MONG/SYS1 | 6CV | B02 |
| ** ON A/C NOT FOR ALL | |||
| 121VU | FLIGHT CONTROLS/FLP/CTL AND/MONG/SYS2 | 8CV | Q21 |
C. Aircraft Maintenance Configuration
(1) Remove the 98D27803000000 LOCKING TOOL-FLAP SLAT LEVER,INT. POSITION from the flap/slat control lever on the panel 114VU.
Subtask 57-52-00-942-072-A ** ON A/C NOT FOR ALL (1) Remove the 98D27803000000 LOCKING TOOL-FLAP SLAT LEVER,INT. POSITION from the flap/slat control lever on the panel 114VU.
D. Removal of Equipment
(1) Remove the access platform(s).
(2) Remove the safety barriers.
(3) Remove the WARNING NOTICE(S).
(4) Remove the ground support and maintenance equipment, the special and standard tools and all other items.
(1) Remove the access platform(s).
(2) Remove the safety barriers.
(3) Remove the WARNING NOTICE(S).
(4) Remove the ground support and maintenance equipment, the special and standard tools and all other items.
Inboard Flap - Attachment Bracket of Pylon Aft Fairing - Inspection Area