W DOC AIRBUS | AMM A320F

Detailed Inspection of Inboard Double Slotted Flap, Drive Strut for Flap and Drive Lever for Flap Track Fairing, Including Attachment Brackets ....


TASK 57-52-00-210-002-A
Detailed Inspection of Inboard Double Slotted Flap, Drive Strut for Flap and Drive Lever for Flap Track Fairing, Including Attachment Brackets ....


WARNING: PUT THE SAFETY DEVICES AND THE WARNING NOTICES IN POSITION BEFORE YOU START A TASK ON OR NEAR:
  • THE FLIGHT CONTROLS
  • THE FLIGHT CONTROL SURFACES
  • THE LANDING GEAR AND THE RELATED DOORS
  • COMPONENTS THAT MOVE.
MOVEMENT OF COMPONENTS CAN KILL OR CAUSE INJURY TO PERSONS AND/OR CAN CAUSE DAMAGE TO THE EQUIPMENT.
WARNING: MAKE SURE THAT THE GROUND SAFETY-LOCKS ARE IN POSITION ON THE LANDING GEAR. THIS WILL PREVENT UNWANTED MOVEMENT OF THE LANDING GEAR, AND THUS POSSIBLE INJURY TO PERSONS AND DAMAGE TO THE AIRCRAFT AND/OR EQUIPMENT.
CAUTION: BE CAREFUL WHEN YOU DO MAINTENANCE TASKS ON THE WING TRAILING EDGE:
  • DO NOT CAUSE DAMAGE TO THE ELECTRICAL CABLE RACEWAYS.
  • DO NOT CAUSE DAMAGE TO THE ELECTRICAL CABLE INSTALLATIONS.
  • MAKE SURE THAT THE ELECTRICAL CABLES ARE INSTALLED CORRECTLY. INCORRECT INSTALLATION CAN CAUSE DAMAGE.
ZONE: 581
ZONE: 681
1. Reason for the Job
Refer to the MPD TASK: 575225-01
DETAILED INSPECTION OF INBOARD DOUBLE-SLOTTED FLAP, DRIVE STRUT FOR FLAP AND DRIVE LEVER FOR FLAP TRACK FAIRING, INCLUDING ATTACHMENT BRACKETS TO THE FLAP AT TRACK 2, LH/RH
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
AR
ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE
No specific
AR
LIGHT SOURCE - SPARK-PROOF
No specific
AR
SAFETY BARRIER(S)
No specific
AR
SAFETY CLIP - CIRCUIT BREAKER
No specific
AR
WARNING NOTICE(S)
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
581
FLAP N° 1
681
FLAP N° 1
531AT, 531CB, 631AT, 631CB
 C. Referenced Information
REFERENCE
DESIGNATION
TASK 27-50-00-866-008-A
Extension of the Flaps on the Ground
TASK 27-50-00-866-008-A-01
Extension of the Flaps/Slats on the Ground
TASK 27-50-00-866-009-A
Retraction of the Flaps on the Ground
TASK 27-50-00-866-009-A-01
Retraction of the Flaps/Slats on the Ground
TASK 57-55-11-000-004-A
Removal of the Flap Track Fairings Nos. 2, 3 and 4
TASK 57-55-11-400-004-A
Installation of the Flap Track Fairings Nos. 2, 3 and 4
SRM 575200
(for corrective action)
3. Job Set-up
Subtask 57-52-00-941-070-A ** ON A/C NOT FOR ALL
A. Safety Precautions
   (1) Put a WARNING NOTICE(S) on the flap/slat control lever (panel 114VU) to tell persons not to operate the flaps.
   (2) As necessary, use the applicable SAFETY BARRIERS, specified by the operator's instructions and your local regulations.
Subtask 57-52-00-860-055-A ** ON A/C NOT FOR ALL
B. Aircraft Maintenance Configuration
WARNING: MAKE SURE THAT THE TRAVEL RANGES OF THE FLIGHT CONTROLS SURFACES ARE CLEAR. MOVEMENT OF FLIGHT CONTROLS CAN CAUSE INJURY TO PERSONS AND/OR DAMAGE TO EQUIPMENT.
   (1) Fully extend the flaps (Ref. AMM TASK 27-50-00-866-008).
   (2) Make sure that the 98D27803000000 LOCKING TOOL-FLAP SLAT LEVER,INT. POSITION is installed on the flap/slat control lever on the panel 114VU.
Subtask 57-52-00-865-089-A ** ON A/C NOT FOR ALL
C. Open, safety and tag this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
49VUFLIGHT CONTROLS/FLP/CTL AND MONG/SYS16CVB07
** ON A/C NOT FOR ALL
49VUFLIGHT CONTROLS/FLP/CTL AND MONG/SYS16CVB02
** ON A/C NOT FOR ALL
121VUFLIGHT CONTROLS/FLP/CTL AND/MONG/SYS28CVQ21
Subtask 57-52-00-010-068-A ** ON A/C NOT FOR ALL
D. Get Access
   (1) Put the ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE in position below the zone 531(631).
   (2) Remove the applicable flap track fairing (Ref. AMM TASK 57-55-11-000-004):
   (3) Put the LIGHT SOURCE - SPARK-PROOF lamp adjacent to the inspection area.
4. Procedure
CAUTION: BE CAREFUL WHEN YOU DO MAINTENANCE TASKS ON THE WING TRAILING EDGE:
  • DO NOT CAUSE DAMAGE TO THE ELECTRICAL CABLE RACEWAYS.
  • DO NOT CAUSE DAMAGE TO THE ELECTRICAL CABLE INSTALLATIONS.
  • MAKE SURE THAT THE ELECTRICAL CABLES ARE INSTALLED CORRECTLY. INCORRECT INSTALLATION CAN CAUSE DAMAGE.
Subtask 57-52-00-210-060-A ** ON A/C NOT FOR ALL
A. Detailed Inspection of Inboard Double Slotted Flap, Drive Strut for Flap and Drive Lever for Flap Track Fairing, Including Attachment Brackets to the Flap at Track 2, LH/RH
   (1) Do an inspection of the drive strut, drive lever and attachment brackets of the flap track 2. Make sure that:
  • there is no damage
  • there is no corrosion
  • there are no cracks or scores
  • the surface protection is in the correct condition.
NOTE: If necessary, refer to the SRM 575200 for the correct repair procedure.
5. Close-up
Subtask 57-52-00-410-070-A ** ON A/C NOT FOR ALL
A. Close Access
   (1) Remove the spark-proof lamp from the inspection area.
   (2) Install the applicable flap track fairing (Ref. AMM TASK 57-55-11-400-004):
   (3) Make sure that the work area is clean and clear of tools and other items.
Subtask 57-52-00-865-090-A ** ON A/C NOT FOR ALL
B. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
49VUFLIGHT CONTROLS/FLP/CTL AND MONG/SYS16CVB07
** ON A/C NOT FOR ALL
49VUFLIGHT CONTROLS/FLP/CTL AND MONG/SYS16CVB02
** ON A/C NOT FOR ALL
121VUFLIGHT CONTROLS/FLP/CTL AND/MONG/SYS28CVQ21
Subtask 57-52-00-860-056-A ** ON A/C NOT FOR ALL
C. Aircraft Maintenance Configuration
   (1) Fully retract the flaps (Ref. AMM TASK 27-50-00-866-009).
Subtask 57-52-00-942-069-A ** ON A/C NOT FOR ALL
D. Removal of Equipment
   (1) Remove the access platform(s).
   (2) Remove the safety barriers.
   (3) Remove the WARNING NOTICE(S).
   (4) Remove the ground support and maintenance equipment, the special and standard tools and all other items.
[Rev.10 from 2021] 2026.04.02 06:31:17 UTC