Removal of the Door - Refuel/Defuel Control Panel
TASK 57-41-37-000-001-A
Removal of the Door - Refuel/Defuel Control Panel
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 57-41-37-941-051-A ** ON A/C NOT FOR ALL
Subtask 57-41-37-010-051-A ** ON A/C NOT FOR ALL Subtask 57-41-37-020-050-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.02 07:28:12 UTC
Removal of the Door - Refuel/Defuel Control Panel
WARNING:
PUT THE SAFETY DEVICES AND THE WARNING NOTICES IN POSITION BEFORE YOU START A TASK ON OR NEAR:
1. Reason for the Job- THE FLIGHT CONTROLS
- THE FLIGHT CONTROL SURFACES
- THE LANDING GEAR AND THE RELATED DOORS
- COMPONENTS THAT MOVE.
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 1 | ACCESS PLATFORM 3M (10 FT) |
| No specific | AR | SAFETY BARRIER(S) |
| No specific | AR | SAFETY CLIP - CIRCUIT BREAKER |
| No specific | AR | WARNING NOTICE(S) |
| 98D27803500001 | 1 | LOCKING TOOL ZERO POS |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 622KB |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 28-25-54-000-001-A | Removal of the Floodlight |
Subtask 57-41-37-941-051-A ** ON A/C NOT FOR ALL
A. Safety Precautions
(1) Install the 98D27803500001 LOCKING TOOL ZERO POS on the flap/slat control lever.
(2) Put a WARNING NOTICE(S) in the cockpit to tell persons not to operate the flaps or slats.
(3) As necessary, use the applicable SAFETY BARRIERS, specified by the operator's instructions and your local regulations.
(4) Put the ACCESS PLATFORM 3M (10 FT) under zone 620 at door 622KB.
Subtask 57-41-37-865-052-A ** ON A/C NOT FOR ALL (1) Install the 98D27803500001 LOCKING TOOL ZERO POS on the flap/slat control lever.
(2) Put a WARNING NOTICE(S) in the cockpit to tell persons not to operate the flaps or slats.
(3) As necessary, use the applicable SAFETY BARRIERS, specified by the operator's instructions and your local regulations.
(4) Put the ACCESS PLATFORM 3M (10 FT) under zone 620 at door 622KB.
B. Open, safety and tag this(these) circuit breaker(s):
4. Procedure| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 122VU | ELEC/REFLNG/NORM | 2PR | S27 |
| 122VU | ELEC/REFLNG/ON/BAT | 1PR | U28 |
Subtask 57-41-37-010-051-A ** ON A/C NOT FOR ALL Subtask 57-41-37-020-050-A ** ON A/C NOT FOR ALL
B. Removal of the Door
(1) Remove the floodlight 32QU (Ref. AMM TASK 28-25-54-000-001).
(2) Hold the door (3) and remove the bolts (4) from the hinges. Put the doorstay back in position on the door (3).
(3) Remove the door (3) from the aircraft.
(1) Remove the floodlight 32QU (Ref. AMM TASK 28-25-54-000-001).
(2) Hold the door (3) and remove the bolts (4) from the hinges. Put the doorstay back in position on the door (3).
(3) Remove the door (3) from the aircraft.
Door - Refuel/Defuel Control Panel