Reactivation of the Wing-Tip Fence
TASK 57-31-00-440-001-A
Reactivation of the Wing-Tip Fence
CDL 57-01
Wing Tip Fence
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Consumable Materials
C. Work Zones and Access Panels
D. Referenced Information
3. Job Set-up
Subtask 57-31-00-860-051-A ** ON A/C NOT FOR ALL
Subtask 57-31-00-440-050-A ** ON A/C NOT FOR ALL
Subtask 57-31-00-865-053-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.02 06:30:54 UTC
Reactivation of the Wing-Tip Fence
WARNING:
PUT THE SAFETY DEVICES AND THE WARNING NOTICES IN POSITION BEFORE YOU START A TASK ON OR NEAR:
- THE FLIGHT CONTROLS
- THE FLIGHT CONTROL SURFACES
- THE LANDING GEAR AND THE RELATED DOORS
- COMPONENTS THAT MOVE.
WARNING:
BE CAREFUL WHEN YOU USE CONSUMABLE MATERIALS. OBEY THE MATERIAL MANUFACTURER'S INSTRUCTIONS AND YOUR LOCAL REGULATIONS.
1. Reason for the JobCDL 57-01
Wing Tip Fence
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | ACCESS PLATFORM 4M (13 FT) |
| No specific | AR | SAFETY BARRIER(S) |
| No specific | AR | SAFETY CLIP - CIRCUIT BREAKER |
| No specific | AR | WARNING NOTICE(S) |
| 98D27803500001 | 1 | LOCKING TOOL ZERO POS |
| REFERENCE | DESIGNATION |
|---|---|
| (Material No.08BAA9) | Non Aqueous Cleaner-General - - |
| (Material No.14SBA1) | Textile-Lint free Cotton - |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 534 | WING TIP |
| 634 | WING TIP |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 24-41-00-861-002-A | Energize the Aircraft Electrical Circuits from the External Power |
| TASK 24-41-00-861-002-A-01 | Energize the Aircraft Electrical Circuits from the APU |
| TASK 24-41-00-861-002-A-02 | Energize the Aircraft Electrical Circuits from Engine 1(2) |
| TASK 24-41-00-862-002-A | De-energize the Aircraft Electrical Circuits Supplied from the External Power |
| TASK 24-41-00-862-002-A-01 | De-energize the Aircraft Electrical Circuits Supplied from the APU |
| TASK 24-41-00-862-002-A-02 | De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2) |
| TASK 33-41-00-710-001-A | Operational Test of the Navigation Lights |
| TASK 33-48-00-710-002-A | Operational Test of the Anti-Collision/Strobe Lighting |
| TASK 57-31-22-000-001-A | Removal of the Wing-Tip Fence |
| TASK 57-31-22-400-001-A | Installation of the Wing-Tip Fence |
Subtask 57-31-00-860-051-A ** ON A/C NOT FOR ALL
A. Aircraft Maintenance Configuration
(1) Make sure that the aircraft electrical circuits are energized
(Ref. AMM TASK 24-41-00-861-002).
Subtask 57-31-00-941-050-A ** ON A/C NOT FOR ALL (1) Make sure that the aircraft electrical circuits are energized
(Ref. AMM TASK 24-41-00-861-002).
B. Safety Precautions
(1) Install the 98D27803500001 LOCKING TOOL ZERO POS on the flap/slat control lever.
(2) As necessary, use the applicable SAFETY BARRIERS, specified by the operator's instructions and your local regulations.
(3) Put WARNING NOTICE(S) in the cockpit to tell persons not to operate the flaps or slats.
(4) Put an ACCESS PLATFORM 4M (13 FT) in position below the applicable wing-tip:
Subtask 57-31-00-865-052-A ** ON A/C NOT FOR ALL (1) Install the 98D27803500001 LOCKING TOOL ZERO POS on the flap/slat control lever.
(2) As necessary, use the applicable SAFETY BARRIERS, specified by the operator's instructions and your local regulations.
(3) Put WARNING NOTICE(S) in the cockpit to tell persons not to operate the flaps or slats.
(4) Put an ACCESS PLATFORM 4M (13 FT) in position below the applicable wing-tip:
- for the left wing, below zone 534
- for the right wing, below zone 634.
C. Open, safety and tag this(these) circuit breaker(s):
4. Procedure| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 122VU | LIGHTING/EXT LT/NAV1/AND LOGO/LT | 1LA | T03 |
| ** ON A/C NOT FOR ALL | |||
| 122VU | LIGHTING/EXT LT/NAV2/AND LOGO/LT | 2LA | T02 |
| 122VU | LIGHTING/WING/STROBE | 10LV | V05 |
| ** ON A/C NOT FOR ALL | |||
| 122VU | LIGHT/EXT LT NAV1/AND LOGO/LT | 1LA | T03 |
Subtask 57-31-00-440-050-A ** ON A/C NOT FOR ALL
A. Reactivation of the Wing-Tip Fence
(1) Reactivation of a wing-tip fence that was not fully removed:
(a) Remove the damaged wing-tip fence (Ref. AMM TASK 57-31-22-000-001).
(b) Install a new wing-tip fence (Ref. AMM TASK 57-31-22-400-001).
(c) Write down in the aircraft log that the wing-tip fence has been reactivated.
(2) Reactivation of a wing-tip fence that was removed:
(a) Remove the aluminium foil adhesive tape from the wing tip.
(b) Clean the wing tip with a Textile-Lint free Cotton - (Material No.14SBA1) made moist with Non Aqueous Cleaner-General - - (Material No.08BAA9) .
(c) Install a new wing-tip fence (Ref. AMM TASK 57-31-22-400-001).
5. Close-up(1) Reactivation of a wing-tip fence that was not fully removed:
(a) Remove the damaged wing-tip fence (Ref. AMM TASK 57-31-22-000-001).
(b) Install a new wing-tip fence (Ref. AMM TASK 57-31-22-400-001).
(c) Write down in the aircraft log that the wing-tip fence has been reactivated.
(2) Reactivation of a wing-tip fence that was removed:
(a) Remove the aluminium foil adhesive tape from the wing tip.
(b) Clean the wing tip with a Textile-Lint free Cotton - (Material No.14SBA1) made moist with Non Aqueous Cleaner-General - - (Material No.08BAA9) .
(c) Install a new wing-tip fence (Ref. AMM TASK 57-31-22-400-001).
Subtask 57-31-00-865-053-A ** ON A/C NOT FOR ALL
A. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
Subtask 57-31-00-710-050-A ** ON A/C NOT FOR ALL | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 122VU | LIGHTING/EXT LT/NAV1/AND LOGO/LT | 1LA | T03 |
| ** ON A/C NOT FOR ALL | |||
| 122VU | LIGHTING/EXT LT/NAV2/AND LOGO/LT | 2LA | T02 |
| 122VU | LIGHTING/WING/STROBE | 10LV | V05 |
| ** ON A/C NOT FOR ALL | |||
| 122VU | LIGHT/EXT LT NAV1/AND LOGO/LT | 1LA | T03 |
B. Operational Test
(1) Do an operational test of the navigation lights (Ref. AMM TASK 33-41-00-710-001).
(2) Do an operational test of the anti-collision/strobe lighting (Ref. AMM TASK 33-48-00-710-002).
Subtask 57-31-00-942-050-A ** ON A/C NOT FOR ALL (1) Do an operational test of the navigation lights (Ref. AMM TASK 33-41-00-710-001).
(2) Do an operational test of the anti-collision/strobe lighting (Ref. AMM TASK 33-48-00-710-002).
C. Removal of Equipment
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Remove the access platform(s).
(3) Remove the safety barriers.
(4) Remove the WARNING NOTICE(S).
(5) Remove the 98D27803500001 LOCKING TOOL ZERO POS from the flap/slat control lever.
(6) Remove the ground support and maintenance equipment, the special and standard tools and all other items.
Subtask 57-31-00-860-052-A ** ON A/C NOT FOR ALL (1) Make sure that the work area is clean and clear of tools and other items.
(2) Remove the access platform(s).
(3) Remove the safety barriers.
(4) Remove the WARNING NOTICE(S).
(5) Remove the 98D27803500001 LOCKING TOOL ZERO POS from the flap/slat control lever.
(6) Remove the ground support and maintenance equipment, the special and standard tools and all other items.
D. Aircraft Maintenance Configuration
(1) De-energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-862-002).
(1) De-energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-862-002).