W DOC AIRBUS | AMM A320F

DETAILED INSPECTION OF OUTER WING, BOTTOM SKIN LOWER SURFACE AT ATTACHMENT TO RIBS AND STRINGERS, IN AREA COVERED BY PYLON FAIRING


TASK 57-20-00-220-811-A
DETAILED INSPECTION OF OUTER WING, BOTTOM SKIN LOWER SURFACE AT ATTACHMENT TO RIBS AND STRINGERS, IN AREA COVERED BY PYLON FAIRING


WARNING: BE CAREFUL WHEN YOU USE CONSUMABLE MATERIALS. OBEY THE MATERIAL MANUFACTURER'S INSTRUCTIONS AND YOUR LOCAL REGULATIONS.
WARNING: PUT THE SAFETY DEVICES AND THE WARNING NOTICES IN POSITION BEFORE YOU START A TASK ON OR NEAR:
  • THE FLIGHT CONTROLS
  • THE FLIGHT CONTROL SURFACES
  • THE LANDING GEAR AND THE RELATED DOORS
  • COMPONENTS THAT MOVE.
MOVEMENT OF COMPONENTS CAN KILL OR CAUSE INJURY TO PERSONS AND/OR CAN CAUSE DAMAGE TO THE EQUIPMENT.
ZONE: 471
ZONE: 481
1. Reason for the Job
Refer to the MPD TASK: 572042-02
NOTE: The effectivity of this task is "ALL". To know if this task is applicable for your aircraft, refer to the MPD task applicability and the weight variant data given in the SRM introduction.
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
1
ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE
No specific
AR
SAFETY BARRIER(S)
No specific
1
WARNING NOTICE(S)
98D27803500001
1
LOCKING TOOL ZERO POS
 B. Consumable Materials
REFERENCE
DESIGNATION
(Material No.08BAA9)
Non Aqueous Cleaner-General - -
(Material No.14SBA1)
Textile-Lint free Cotton -
 C. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
471
PYLON LEADING EDGE
481
PYLON LEADING EDGE
472AR, 472BR, 475CL, 476AR, 476BR, 476CR, 482AR, 482BR, 482CR, 485CL, 486AR, 486BR, 486CR
471AL, 471BL, 471CL, 475AL, 475BL, 481AL, 481BL, 485AL, 485BL
471AR, 471BR, 471CR, 471DL, 475AR, 475BR, 481AR, 481BR, 481CL, 481CR, 481DR, 485AR, 485BR
 D. Referenced Information
REFERENCE
DESIGNATION
TASK 54-53-11-000-002-A
Removal of the Pylon-to-Wing Access Panels
TASK 54-53-11-000-002-B
Removal of the Pylon-to-Wing Access Panels
TASK 54-53-11-400-002-A
Installation of the Pylon-to-Wing Access Panels
TASK 54-53-11-400-002-B
Installation of the Pylon-to-Wing Access Panels
SRM 572000
(for corrective action)
3. Job Set-up
Subtask 57-20-00-941-120-A
A. Safety Precautions
   (1) As necessary, use the applicable SAFETY BARRIERS, specified by the operator's instructions and your local regulations.
   (2) Install the 98D27803500001 LOCKING TOOL ZERO POS on the flap/slat control lever.
   (3) Put WARNING NOTICE(S) in the cockpit to tell persons not to operate the flaps or slats.
Subtask 57-20-00-010-124-A
B. Get Access
   (1) Put the ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE in position at the applicable engine pylon zone 471(481).
Subtask 57-20-00-010-125-A ** ON A/C NOT FOR ALL
C. Get Access
   (1) On the LH side:
     (a) Remove the applicable pylon-to-wing access panels (Ref. AMM TASK 54-53-11-000-002):
Subtask 57-20-00-010-126-A ** ON A/C NOT FOR ALL
D. Get Access
   (1) On the RH side:
     (a) Remove the applicable pylon-to-wing access panels (Ref. AMM TASK 54-53-11-000-002):
Subtask 57-20-00-010-125-B ** ON A/C NOT FOR ALL
E. Get Access
   (1) On the LH side:
     (a) Remove the applicable pylon-to-wing access panels (Ref. AMM TASK 54-53-11-000-002):
Subtask 57-20-00-010-126-B ** ON A/C NOT FOR ALL
F. Get Access
   (1) On the RH side:
     (a) Remove the applicable pylon-to-wing access panels (Ref. AMM TASK 54-53-11-000-002):
4. Procedure
Subtask 57-20-00-100-057-A
A. Preparation for Inspection
   (1) Use a Textile-Lint free Cotton - (Material No.14SBA1) , made moist with Non Aqueous Cleaner-General - - (Material No.08BAA9) to clean the applicable area for inspection.
Subtask 57-20-00-220-065-A
B. Detailed Inspection Of Outer Wing, Bottom Skin Lower Surface At Attachment To Ribs And Stringers, In Area Covered By Pylon Fairing
   (1) Do a detail inspection and make sure that:
  • There is no damage
  • There is no corrosion
  • There are no cracks
  • There are no dents, burrs, scores or scratches
  • There are no loose or damaged fasteners
  • The surface protection is in the correct condition.
NOTE: If necessary, refer to the SRM 572000 for the correct repair procedure.
5. Close-up
Subtask 57-20-00-410-119-A
A. Close Access
   (1) Make sure that the work area is clean and clear of tools and other items.
Subtask 57-20-00-410-120-A ** ON A/C NOT FOR ALL
B. Close Access
   (1) On the LH side:
     (a) Install the applicable pylon-to-wing access panels (Ref. AMM TASK 54-53-11-400-002):
Subtask 57-20-00-410-121-A ** ON A/C NOT FOR ALL
C. Close Access
   (1) On the RH side:
     (a) Install the applicable pylon-to-wing access panels (Ref. AMM TASK 54-53-11-400-002):
Subtask 57-20-00-410-120-B ** ON A/C NOT FOR ALL
D. Close Access
   (1) On the LH side:
     (a) Install the applicable pylon-to-wing access panels (Ref. AMM TASK 54-53-11-400-002):
Subtask 57-20-00-410-121-B ** ON A/C NOT FOR ALL
E. Close Access
   (1) On the RH side:
     (a) Install the applicable pylon-to-wing access panels (Ref. AMM TASK 54-53-11-400-002):
Subtask 57-20-00-942-121-A
F. Removal of Equipment
   (1) Remove the safety barriers.
   (2) Remove the access platform(s).
   (3) Remove the 98D27803500001 LOCKING TOOL ZERO POS from the flap/slat control lever.
   (4) Remove the WARNING NOTICE(S).
   (5) Make sure that the work area is clean and clear of tools and other items.
   (6) Remove the ground support and maintenance equipment, the special and standard tools and all other items.
[Rev.8 from Aug 2017] 2026.04.02 06:30:39 UTC