Detailed Inspection of Outer Wing, RIB 5, Aft of Bolted Panel
TASK 57-20-00-200-014-A
Detailed Inspection of Outer Wing, RIB 5, Aft of Bolted Panel
Refer to the MPD TASK: 572026-01
DETAILED INSPECTION OF OUTER WING, RIB 5, AFT OF BOLTED PANEL
A. Fixtures, Tools, Test and Support Equipment
B. Consumable Materials
C. Work Zones and Access Panels
D. Referenced Information
3. Job Set-up
Subtask 57-20-00-941-063-A
Subtask 57-20-00-110-064-A
Subtask 57-20-00-410-064-A
[Rev.10 from 2021]
2026.04.02 06:30:35 UTC
Detailed Inspection of Outer Wing, RIB 5, Aft of Bolted Panel
WARNING:
PUT THE SAFETY DEVICES AND THE WARNING NOTICES IN POSITION BEFORE YOU START A TASK ON OR NEAR:
- THE FLIGHT CONTROLS
- THE FLIGHT CONTROL SURFACES
- THE LANDING GEAR AND THE RELATED DOORS
- COMPONENTS THAT MOVE.
WARNING:
BE CAREFUL WHEN YOU USE CONSUMABLE MATERIALS. OBEY THE MATERIAL MANUFACTURER'S INSTRUCTIONS AND YOUR LOCAL REGULATIONS.
1. Reason for the JobRefer to the MPD TASK: 572026-01
DETAILED INSPECTION OF OUTER WING, RIB 5, AFT OF BOLTED PANEL
NOTE: The effectivity of this task is "ALL". To know if this task is applicable for your aircraft, refer to the MPD task applicability and the weight variant data given in the SRM introduction.
2. Job Set-up InformationA. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | ACCESS PLATFORM 2M (6 FT) |
| No specific | AR | SAFETY BARRIER(S) |
| No specific | AR | WARNING NOTICE(S) |
| 98D27803500001 | 1 | LOCKING TOOL ZERO POS |
| REFERENCE | DESIGNATION |
|---|---|
| (Material No.08BAA9) | Non Aqueous Cleaner-General - - |
| (Material No.14SBA1) | Textile-Lint free Cotton - |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 540 | FUEL TANK |
| 640 | FUEL TANK |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 28-10-00-910-001-A | Safety Procedures When You Do Work in a Fuel Tank |
| TASK 28-10-00-910-002-A | Access to the Fuel Tanks and the Work Areas |
| TASK 57-27-11-000-001-A | Removal of the Access Panel |
| TASK 57-27-11-400-001-A | Installation of the Access Panel |
| SRM 572100 | (for corrective action) |
Subtask 57-20-00-941-063-A
A. Safety Precautions
(2) Install the 98D27803500001 LOCKING TOOL ZERO POS on the flap/slat control lever.
(3) Put a WARNING NOTICE(S) in the cockpit to tell persons not to operate the flaps or slats.
(4) Put the SAFETY BARRIER(S) in position.
Subtask 57-20-00-010-063-A WARNING:
BEFORE YOU DO WORK IN OR NEAR A FUEL TANK, MAKE SURE THAT YOU OBEY ALL THE SAFETY PROCEDURES. THIS WILL PREVENT INJURY TO PERSONS AND/OR DAMAGE TO THE AIRCRAFT.
(1) Obey the fuel safety precautions (Ref. AMM TASK 28-10-00-910-001). (2) Install the 98D27803500001 LOCKING TOOL ZERO POS on the flap/slat control lever.
(3) Put a WARNING NOTICE(S) in the cockpit to tell persons not to operate the flaps or slats.
(4) Put the SAFETY BARRIER(S) in position.
B. Get Access
(1) Put the ACCESS PLATFORM 2M (6 FT) in position below the zone 540(640).
(2) Remove the applicable access panels:
4. Procedure(1) Put the ACCESS PLATFORM 2M (6 FT) in position below the zone 540(640).
(2) Remove the applicable access panels:
- for the left wing, remove 540AB and 540BB
- for the right wing, remove 640AB and 640BB (Ref. AMM TASK 57-27-11-000-001) and (Ref. AMM TASK 28-10-00-910-002).
Subtask 57-20-00-110-064-A
A. Preparation for Inspection
(1) Use a clean Textile-Lint free Cotton - (Material No.14SBA1) , made moist with Non Aqueous Cleaner-General - - (Material No.08BAA9) , to clean:
Subtask 57-20-00-210-061-A (1) Use a clean Textile-Lint free Cotton - (Material No.14SBA1) , made moist with Non Aqueous Cleaner-General - - (Material No.08BAA9) , to clean:
- the outer wing, RIB 5, aft of the bolted panel.
B. Detailed Inspection of Outer Wing, RIB 5, Aft of Bolted Panel
(1) Examine the applicable inspection area. Make sure that:
5. Close-up(1) Examine the applicable inspection area. Make sure that:
- there is no corrosion or damage
- there are no scratches or scores
- there are no loose or damaged fasteners
- the surface protection is in the correct condition.
NOTE: If necessary, refer to the SRM 572100 for the correct repair procedure.
Subtask 57-20-00-410-064-A
A. Close Access
(1) Make sure that the work area is clean and clear of tool(s) and other items.
(2) Install the applicable access panels:
Subtask 57-20-00-942-064-A (1) Make sure that the work area is clean and clear of tool(s) and other items.
(2) Install the applicable access panels:
- for the left wing, install 540AB and 540BB
- for the right wing, install 640AB and 640BB, (Ref. AMM TASK 57-27-11-400-001).
B. Removal of Equipment
(1) Remove the safety barriers.
(2) Remove the access platform(s).
(3) Remove the 98D27803500001 LOCKING TOOL ZERO POS from the flap/slat control lever.
(4) Remove the WARNING NOTICE(S).
(5) Remove the ground support and maintenance equipment, the special and standard tools and all other items.
(1) Remove the safety barriers.
(2) Remove the access platform(s).
(3) Remove the 98D27803500001 LOCKING TOOL ZERO POS from the flap/slat control lever.
(4) Remove the WARNING NOTICE(S).
(5) Remove the ground support and maintenance equipment, the special and standard tools and all other items.
Details of the RIB5, Aft of the Bolted Panel