Installation of Access Cover 148AZ or/and the ACT-Equipment Support-Door
TASK 57-17-11-400-001-A-01
Installation of Access Cover 148AZ or/and the ACT-Equipment Support-Door
A. Fixtures, Tools, Test and Support Equipment
B. Consumable Materials
C. Work Zones and Access Panels
D. Expendable Parts
E. Referenced Information
3. Job Set-up
Subtask 57-17-11-860-054-A
Subtask 57-17-11-914-054-A
Subtask 57-17-11-410-055-A
[Rev.8 from Aug 2017]
2026.04.02 06:30:34 UTC
Installation of Access Cover 148AZ or/and the ACT-Equipment Support-Door
WARNING:
MAKE SURE THAT YOU HAVE THE CORRECT FIRE FIGHTING EQUIPMENT AVAILABLE.
WARNING:
OBEY THE SAFETY PROCEDURES WHEN YOU DO WORK IN A FUEL TANK.
WARNING:
BE CAREFUL NOT TO GET AIRCRAFT FUEL IN YOUR MOUTH OR IN YOUR EYES.
IF YOU GET FUEL ON YOUR SKIN OR ON YOUR CLOTHES, FLUSH IT IMMEDIATELY WITH WATER.
IF NECESSARY, GET MEDICAL HELP.
AIRCRAFT FUEL IS POISONOUS.
WARNING:
MAKE SURE THAT THE GROUND SAFETY-LOCKS ARE IN POSITION ON THE LANDING GEAR. THIS WILL PREVENT UNWANTED MOVEMENT OF THE LANDING GEAR, AND THUS POSSIBLE INJURY TO PERSONS AND DAMAGE TO THE AIRCRAFT AND/OR EQUIPMENT.
WARNING:
BE CAREFUL WHEN YOU USE CONSUMABLE MATERIALS. OBEY THE MATERIAL MANUFACTURER'S INSTRUCTIONS AND YOUR LOCAL REGULATIONS.
1. Reason for the JobNOTE: This task is applicable to aircraft with Additional Center Tank
2. Job Set-up InformationA. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE |
| No specific | Torque wrench: range to between 0.9 and 0.8 m.daN (79.65 and 70.80 lbf.in ) ![]() |
| REFERENCE | DESIGNATION |
|---|---|
| (Material No.06AAC1) | Polysulfide Sealant-General Purpose Interfay - |
| (Material No.06CDD1) | Silicone Adhesive Sealant-Solvant Resistant One part - |
| (Material No.08BAA9) | Non Aqueous Cleaner-General - - |
| (Material No.14SBA1) | Textile-Lint free Cotton - |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 734, 744 |
| FIG.ITEM | DESIGNATION | IPC-CSN |
|---|---|---|
| 12 | seal | AIPC 57-17-11-01-030 |
| 33 | seal | AIPC 57-17-11-01-030 |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 12-11-28-650-003-A | Pressure Refuel with Automatic Control |
| TASK 20-28-00-912-802-A | Electrical Bonding - General Maintenance Procedure |
| TASK 24-41-00-862-002-A | De-energize the Aircraft Electrical Circuits Supplied from the External Power |
| TASK 24-41-00-862-002-A-01 | De-energize the Aircraft Electrical Circuits Supplied from the APU |
| TASK 24-41-00-862-002-A-02 | De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2) |
| TASK 28-00-00-910-001-A | Fuel Safety Procedures |
| TASK 28-10-00-910-001-A | Safety Procedures When You Do Work in a Fuel Tank |
| TASK 28-21-00-710-008-A | Operational Check of Air Release Valves to Ensure Adequate Fuel Flow Under Suction Feed Conditions |
| TASK 28-25-00-650-001-A | Pressure Defuel |
| TASK 28-25-00-650-003-A | To Drain Remaining Fuel from the Wing Tanks and the Center Tank |
| TASK 28-25-00-650-003-A-01 | To Drain Remaining Fuel from the Wing Tanks and the Center Tank |
| TASK 28-25-00-869-001-A | Fuel Transfer |
| TASK 28-28-11-400-001-A | Installation of the ACT Fuel Transfer-Pump Pressure-Switch |
| TASK 28-28-31-400-001-A | Installation of the ACT Fuel-Transfer-Pump Mounting-Plate |
| TASK 28-28-33-400-001-A | Installation of the ACT Fuel Transfer-Valve |
| TASK 28-42-00-740-001-A | Status Report (BITE) |
| TASK 28-46-00-740-001-A | Functional (BITE) Test |
| TASK 32-12-00-010-001-A | Open the Main Gear Doors for Access |
| TASK 32-12-00-410-001-A | Close the Main Gear Doors after Access |
| TASK 57-17-11-400-003-A | Installation of the Protective Cover of the ACT-Equipment Support Door |
| TASK 71-00-00-710-003-A | Engine Automatic Start |
| TASK 71-00-00-710-003-B | Engine Automatic Start |
| TASK 71-00-00-710-004-A | Engine Manual Start |
| TASK 71-00-00-710-004-B | Engine Manual Start |
| TASK 73-11-10-920-001-A | Remove, Inspect and Replace Fuel Filter Element |
| TASK 73-11-10-920-001-B | Remove, Inspect and Replace Fuel Filter Element |
Subtask 57-17-11-860-054-A
A. Aircraft Maintenance Configuration
(1) Make sure that the fuel safety procedures are obeyed (Ref. AMM TASK 28-00-00-910-001), (Ref. AMM TASK 28-10-00-910-001).
(2) Make sure that the center tank is defueled (Ref. AMM TASK 28-25-00-650-001) and the fuel is filled into a different tank (Ref. AMM TASK 28-25-00-869-001).
(3) Make sure that the remaining fuel is drained (Ref. AMM TASK 28-25-00-650-003).
(4) Make sure that (MLG) door 734 ( 744) is open and the safety devices are installed (Ref. AMM TASK 32-12-00-010-001).
(5) Make sure that the ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE is in position at zone 147 or 148.
Subtask 57-17-11-865-064-A (1) Make sure that the fuel safety procedures are obeyed (Ref. AMM TASK 28-00-00-910-001), (Ref. AMM TASK 28-10-00-910-001).
(2) Make sure that the center tank is defueled (Ref. AMM TASK 28-25-00-650-001) and the fuel is filled into a different tank (Ref. AMM TASK 28-25-00-869-001).
(3) Make sure that the remaining fuel is drained (Ref. AMM TASK 28-25-00-650-003).
(4) Make sure that (MLG) door 734 ( 744) is open and the safety devices are installed (Ref. AMM TASK 32-12-00-010-001).
(5) Make sure that the ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE is in position at zone 147 or 148.
B. Make sure that this(these) circuit breaker(s) is(are) open, safetied and tagged:
4. Procedure| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C ALL | |||
| 49VU | FUEL/X FEED/VALVE/MOT1 | 2QE | A12 |
| ** ON A/C NOT FOR ALL | |||
| 121VU | FUEL/CTR TK/PUMP2 SPLY | 30QA | P26 |
| 121VU | FUEL/CTR TK/PUMP1 SPLY | 29QA | P23 |
| ** ON A/C ALL | |||
| 121VU | FUEL/RFL/DFL/SPLY | 2QU | L24 |
| 121VU | FUEL/RFL/DFL/XFR/DEFUEL/VALVE | 1QU | L23 |
| 121VU | FUEL/L WING TK/PUMP2 SPLY | 7QA | N26 |
| 121VU | FUEL/L WING TK/PUMP1 SPLY | 1QA | N23 |
| 121VU | FUEL/R WING TK/PUMP2 SPLY | 8QA | Q26 |
| 121VU | FUEL/R WING TK/PUMP1 SPLY | 2QA | Q23 |
Subtask 57-17-11-914-054-A
A. Preparation for Installation
(1) Make sure that the parts retained from the removed component are clean and in the correct condition.
(2) Clean the component interfaces and the adjacent area.
(3) Do an inspection of the component interfaces and the adjacent area.
(4) Use Textile-Lint free Cotton - (Material No.14SBA1) and Non Aqueous Cleaner-General - - (Material No.08BAA9) to clean the contact surface of the seals (12) and (33), the access cover (11) and the ACT equipment support-door (34).
(5) Use Textile-Lint free Cotton - (Material No.14SBA1) and Silicone Adhesive Sealant-Solvant Resistant One part - (Material No.06CDD1) ) to clean the contact surface of the fittings (24), (31) and (41), the access cover (11) and the ACT equipment support-door (34).
(6) Apply Silicone Adhesive Sealant-Solvant Resistant One part - (Material No.06CDD1) on new AIPC 57-17-11-01-030 seal (12) and new AIPC 57-17-11-01-030 seal (33).
(7) Install:
(a) The seal (12) on the access cover (11)
(b) The seal (33) on the ACT equipment support-door (34).
(8) Make sure that the seals (12) and (33) are correctly installed in their grooves and in correct orientation.
(9) Use Textile-Lint free Cotton - (Material No.14SBA1) and Non Aqueous Cleaner-General - - (Material No.08BAA9) to clean the surface around the seals (12) and (33) to remove the unwanted sealant.
Subtask 57-17-11-210-060-A (1) Make sure that the parts retained from the removed component are clean and in the correct condition.
(2) Clean the component interfaces and the adjacent area.
(3) Do an inspection of the component interfaces and the adjacent area.
(4) Use Textile-Lint free Cotton - (Material No.14SBA1) and Non Aqueous Cleaner-General - - (Material No.08BAA9) to clean the contact surface of the seals (12) and (33), the access cover (11) and the ACT equipment support-door (34).
(5) Use Textile-Lint free Cotton - (Material No.14SBA1) and Silicone Adhesive Sealant-Solvant Resistant One part - (Material No.06CDD1) ) to clean the contact surface of the fittings (24), (31) and (41), the access cover (11) and the ACT equipment support-door (34).
(6) Apply Silicone Adhesive Sealant-Solvant Resistant One part - (Material No.06CDD1) on new AIPC 57-17-11-01-030 seal (12) and new AIPC 57-17-11-01-030 seal (33).
(7) Install:
(a) The seal (12) on the access cover (11)
(b) The seal (33) on the ACT equipment support-door (34).
(8) Make sure that the seals (12) and (33) are correctly installed in their grooves and in correct orientation.
(9) Use Textile-Lint free Cotton - (Material No.14SBA1) and Non Aqueous Cleaner-General - - (Material No.08BAA9) to clean the surface around the seals (12) and (33) to remove the unwanted sealant.
B. Bonding Strip Integrity Check
(1) Do an inspection of the bonding strips in the CWB. Make sure that:
Subtask 57-17-11-420-057-A ** ON A/C NOT FOR ALL (1) Do an inspection of the bonding strips in the CWB. Make sure that:
- They are correctly installed
- There is no corrosion and damage.
C. Installation of the Access Cover 148AZ
(1) Put the access cover (11) in position on the frame.
(2) Hold the access cover (11) in position when you install the fasteners.
(3) Install the washers (18) and (17) and the screws (16).
(4) TORQUE the screws (16) to between 0.9 and 0.8 m.daN (79.65 and 70.80 lbf.in )
.
(5) Do the electrical bonding when you install the bonding strip (15) (Ref. AMM TASK 20-28-00-912-802).
(6) Install the bonding strip (15), the washer (14) and the bolt (13) and tighten it.
Subtask 57-17-11-420-057-B ** ON A/C NOT FOR ALL (1) Put the access cover (11) in position on the frame.
(2) Hold the access cover (11) in position when you install the fasteners.
(3) Install the washers (18) and (17) and the screws (16).
(4) TORQUE the screws (16) to between 0.9 and 0.8 m.daN (79.65 and 70.80 lbf.in )
. (5) Do the electrical bonding when you install the bonding strip (15) (Ref. AMM TASK 20-28-00-912-802).
(6) Install the bonding strip (15), the washer (14) and the bolt (13) and tighten it.
C. Installation of Access Cover 148AZ
(3) If the placards are damaged, missing, painted over or you cannot easily read them, replace them at the next maintenance opportunity.
(5) TORQUE the screws (16) to between 0.9 and 0.8 m.daN (79.65 and 70.80 lbf.in )
.
(6) Do the electrical bonding when you install the bonding strip (15) (Ref. AMM TASK 20-28-00-912-802).
(7) Install the bonding strip (15), the washer (14) and the bolt (13) and tighten it.
Subtask 57-17-11-420-058-A ** ON A/C NOT FOR ALL WARNING:
MAKE SURE THAT THE WARNING/CAUTION PLACARDS ARE INSTALLED AND YOU CAN EASILY READ THEM. THESE PLACARDS TELL PERSONS THAT THERE IS A POSSIBLE LOW OXYGEN CONTENT IN:
(1) Do a visual inspection to look for placards that are: - THE AREA BEHIND THE ACCESS PANEL(S)
- THE ADJACENT AREAS WHEN THE ACCESS PANEL(S) IS(ARE) OPEN.
- Damaged
- Missing
- Painted over.
(3) If the placards are damaged, missing, painted over or you cannot easily read them, replace them at the next maintenance opportunity.
NOTE: Hold the access cover (11) in position when you install the fasteners.
(4) Install the washers (18), the washers (17) and the screws (16). (5) TORQUE the screws (16) to between 0.9 and 0.8 m.daN (79.65 and 70.80 lbf.in )
. (6) Do the electrical bonding when you install the bonding strip (15) (Ref. AMM TASK 20-28-00-912-802).
(7) Install the bonding strip (15), the washer (14) and the bolt (13) and tighten it.
D. Installation of the ACT-Equipment Support Door
(1) Apply Polysulfide Sealant-General Purpose Interfay - (Material No.06AAC1) on the contact surface of the fittings (24), (31) and (41) with the ACT equipment support-door (34).
(2) Put the ACT equipment support-door (34) and the fittings (24), (31) and (41) in position on the frame.
(3) Hold the ACT equipment support-door (34) and the fittings (24), (31) and (41) in position when you install the fasteners.
(4) Install the washers (23) and (22) and the screws (21).
(5) TORQUE the screws (21) to between 0.9 and 0.8 m.daN (79.65 and 70.80 lbf.in )
.
(6) Use Textile-Lint free Cotton - (Material No.14SBA1) and Non Aqueous Cleaner-General - - (Material No.08BAA9) to remove the unwanted sealant.
(7) Install the bonding strip (29), the washer (32) and the bolt (30) and tighten it.
(8) Do the electrical bonding when you install the bonding strip (29) (Ref. AMM TASK 20-28-00-912-802).
(9) Install the bonding strips (25) and (28), the washer (26) and the bolt (27) and tighten it.
(10) Do the electrical bonding when you install the bonding strips (25) and (28) (Ref. AMM TASK 20-28-00-912-802).
(11) Install the bonding strip (38), the washer (40) and the bolt (39) and tighten it.
(12) Do the electrical bonding when you install the bonding strip (38) (Ref. AMM TASK 20-28-00-912-802).
(13) Install the bonding strips (37) and (38), the washer (35) and the bolt (36) and tighten it.
(14) Do the electrical bonding when you install the bonding strips (37) and (38) (Ref. AMM TASK 20-28-00-912-802).
(15) Install the following components:
Subtask 57-17-11-420-058-C ** ON A/C NOT FOR ALL (1) Apply Polysulfide Sealant-General Purpose Interfay - (Material No.06AAC1) on the contact surface of the fittings (24), (31) and (41) with the ACT equipment support-door (34).
(2) Put the ACT equipment support-door (34) and the fittings (24), (31) and (41) in position on the frame.
(3) Hold the ACT equipment support-door (34) and the fittings (24), (31) and (41) in position when you install the fasteners.
(4) Install the washers (23) and (22) and the screws (21).
(5) TORQUE the screws (21) to between 0.9 and 0.8 m.daN (79.65 and 70.80 lbf.in )
. (6) Use Textile-Lint free Cotton - (Material No.14SBA1) and Non Aqueous Cleaner-General - - (Material No.08BAA9) to remove the unwanted sealant.
(7) Install the bonding strip (29), the washer (32) and the bolt (30) and tighten it.
(8) Do the electrical bonding when you install the bonding strip (29) (Ref. AMM TASK 20-28-00-912-802).
(9) Install the bonding strips (25) and (28), the washer (26) and the bolt (27) and tighten it.
(10) Do the electrical bonding when you install the bonding strips (25) and (28) (Ref. AMM TASK 20-28-00-912-802).
(11) Install the bonding strip (38), the washer (40) and the bolt (39) and tighten it.
(12) Do the electrical bonding when you install the bonding strip (38) (Ref. AMM TASK 20-28-00-912-802).
(13) Install the bonding strips (37) and (38), the washer (35) and the bolt (36) and tighten it.
(14) Do the electrical bonding when you install the bonding strips (37) and (38) (Ref. AMM TASK 20-28-00-912-802).
(15) Install the following components:
- Fuel transfer pump 163QM (Ref. AMM D/O 28-28-31-40)
- Refuel valve canister 164QM (Ref. AMM D/O 28-25-52-40)
- Fuel transfer valve 165QM (Ref. AMM D/O 28-28-33-40)
- Pressure switch 2QH (Ref. AMM D/O 28-28-11-40).
D. Installation of the ACT-Equipment Support Door
(3) If the placards are damaged, missing, painted over or you cannot easily read them, replace them at the next maintenance opportunity.
(4) Apply Polysulfide Sealant-General Purpose Interfay - (Material No.06AAC1) on the contact surface of the fittings (24), (31) and (41) with the ACT-equipment support door (34).
(5) Put the ACT-equipment support door ((34) and the fittings (24), (31) and (34) in position on the frame.
(7) TORQUE the screws (21) to between 0.9 and 0.8 m.daN (79.65 and 70.80 lbf.in )
.
(8) Remove the unwanted sealant with Non Aqueous Cleaner-General - - (Material No.08BAA9) and with Textile-Lint free Cotton - (Material No.14SBA1) .
(9) Install the bonding strip (29), the washer (32) and the bolt (30) and tighten it.
(10) You must do the electrical bonding when you install the bonding strip (29) (Ref. AMM TASK 20-28-00-912-802).
(11) Install the bonding strips (25) and (28), the washer (26) and the bolt (27) and tighten it.
(12) Do the electrical bonding when you install the bonding strips (25) and (28) (Ref. AMM TASK 20-28-00-912-802).
(13) Install the bonding strip (38), the washer (40) and the bolt (39) and tighten it.
(14) Do the electrical bonding when you install the bonding strip (38) (Ref. AMM TASK 20-28-00-912-802).
(15) Install the bonding strips (37) and (38), the washer (35) and the bolt (36) and tighten it.
(16) Do the electrical bonding when you install the bonding strips (37) and (38) (Ref. AMM TASK 20-28-00-912-802).
(17) Install the following components:
Subtask 57-17-11-420-058-K ** ON A/C NOT FOR ALL WARNING:
MAKE SURE THAT THE WARNING/CAUTION PLACARDS ARE INSTALLED AND YOU CAN EASILY READ THEM. THESE PLACARDS TELL PERSONS THAT THERE IS A POSSIBLE LOW OXYGEN CONTENT IN:
(1) Do a visual inspection to look for placards that are: - THE AREA BEHIND THE ACCESS PANEL(S)
- THE ADJACENT AREAS WHEN THE ACCESS PANEL(S) IS(ARE) OPEN.
- Damaged
- Missing
- Painted over.
(3) If the placards are damaged, missing, painted over or you cannot easily read them, replace them at the next maintenance opportunity.
(4) Apply Polysulfide Sealant-General Purpose Interfay - (Material No.06AAC1) on the contact surface of the fittings (24), (31) and (41) with the ACT-equipment support door (34).
(5) Put the ACT-equipment support door ((34) and the fittings (24), (31) and (34) in position on the frame.
NOTE: Hold the ACT-equipment support door (34) and the fittings (24), (31) and (41) in position when you install the fasteners.
(6) Install the washers (23), the washers (22) and the screws (21). (7) TORQUE the screws (21) to between 0.9 and 0.8 m.daN (79.65 and 70.80 lbf.in )
. (8) Remove the unwanted sealant with Non Aqueous Cleaner-General - - (Material No.08BAA9) and with Textile-Lint free Cotton - (Material No.14SBA1) .
(9) Install the bonding strip (29), the washer (32) and the bolt (30) and tighten it.
(10) You must do the electrical bonding when you install the bonding strip (29) (Ref. AMM TASK 20-28-00-912-802).
(11) Install the bonding strips (25) and (28), the washer (26) and the bolt (27) and tighten it.
(12) Do the electrical bonding when you install the bonding strips (25) and (28) (Ref. AMM TASK 20-28-00-912-802).
(13) Install the bonding strip (38), the washer (40) and the bolt (39) and tighten it.
(14) Do the electrical bonding when you install the bonding strip (38) (Ref. AMM TASK 20-28-00-912-802).
(15) Install the bonding strips (37) and (38), the washer (35) and the bolt (36) and tighten it.
(16) Do the electrical bonding when you install the bonding strips (37) and (38) (Ref. AMM TASK 20-28-00-912-802).
(17) Install the following components:
- the fuel transfer pump 163QM (Ref. AMM D/O 28-28-31-40)
- the refuel valve canister 164QM (Ref. AMM D/O 28-25-52-40)
- the fuel transfer valve 165QM (Ref. AMM D/O 28-28-33-40)
- the pressure switch 2QH (Ref. AMM D/O 28-28-11-40).
D. Installation of the ACT-Equipment Support Door
(3) If the placards are damaged, missing, painted over or you cannot easily read them, replace them at the next maintenance opportunity.
(4) Apply Polysulfide Sealant-General Purpose Interfay - (Material No.06AAC1) on the contact surface of the fittings (24), (31) and (41) with the ACT equipment support-door (34).
(5) Put the ACT equipment support-door (34) and the fittings (24), (31) and (41) in position on the frame.
(7) TORQUE the screws (21) to between 0.9 and 0.8 m.daN (79.65 and 70.80 lbf.in )
.
(8) Use Textile-Lint free Cotton - (Material No.14SBA1) and Non Aqueous Cleaner-General - - (Material No.08BAA9) to remove the unwanted sealant.
(9) Install the bonding strip (29), the washer (32) and the bolt (30) and tighten it.
(10) Do the electrical bonding when you install the bonding strip (29) (Ref. AMM TASK 20-28-00-912-802).
(11) Install the bonding strips (25) and (28), the washer (26) and the bolt (27) and tighten it.
(12) Do the electrical bonding when you install the bonding strips (25) and (28) (Ref. AMM TASK 20-28-00-912-802).
(13) Install the bonding strip (38), the washer (40) and the bolt (39) and tighten it.
(14) Do the electrical bonding when you install the bonding strip (38) (Ref. AMM TASK 20-28-00-912-802).
(15) Install the bonding strips (37) and (38), the washer (35) and the bolt (36) and tighten it.
(16) Do the electrical bonding when you install the bonding strips (37) and (38) (Ref. AMM TASK 20-28-00-912-802).
(17) Install the following components:
Subtask 57-17-11-865-065-A WARNING:
MAKE SURE THAT THE WARNING/CAUTION PLACARDS ARE INSTALLED AND YOU CAN EASILY READ THEM. THESE PLACARDS TELL PERSONS THAT THERE IS A POSSIBLE LOW OXYGEN CONTENT IN:
(1) Do a visual inspection to look for placards that are: - THE AREA BEHIND THE ACCESS PANEL(S)
- THE ADJACENT AREAS WHEN THE ACCESS PANEL(S) IS(ARE) OPEN.
- Damaged
- Missing
- Painted over.
(3) If the placards are damaged, missing, painted over or you cannot easily read them, replace them at the next maintenance opportunity.
(4) Apply Polysulfide Sealant-General Purpose Interfay - (Material No.06AAC1) on the contact surface of the fittings (24), (31) and (41) with the ACT equipment support-door (34).
(5) Put the ACT equipment support-door (34) and the fittings (24), (31) and (41) in position on the frame.
NOTE: Hold the ACT equipment support-door (34) and the fittings (24), (31) and (41) in position when you install the fasteners.
(6) Install the washers (23), the washers (22) and the screws (21). (7) TORQUE the screws (21) to between 0.9 and 0.8 m.daN (79.65 and 70.80 lbf.in )
. (8) Use Textile-Lint free Cotton - (Material No.14SBA1) and Non Aqueous Cleaner-General - - (Material No.08BAA9) to remove the unwanted sealant.
(9) Install the bonding strip (29), the washer (32) and the bolt (30) and tighten it.
(10) Do the electrical bonding when you install the bonding strip (29) (Ref. AMM TASK 20-28-00-912-802).
(11) Install the bonding strips (25) and (28), the washer (26) and the bolt (27) and tighten it.
(12) Do the electrical bonding when you install the bonding strips (25) and (28) (Ref. AMM TASK 20-28-00-912-802).
(13) Install the bonding strip (38), the washer (40) and the bolt (39) and tighten it.
(14) Do the electrical bonding when you install the bonding strip (38) (Ref. AMM TASK 20-28-00-912-802).
(15) Install the bonding strips (37) and (38), the washer (35) and the bolt (36) and tighten it.
(16) Do the electrical bonding when you install the bonding strips (37) and (38) (Ref. AMM TASK 20-28-00-912-802).
(17) Install the following components:
- Fuel transfer pump 163QM (Ref. AMM TASK 28-28-31-400-001)
- Fuel transfer valve 165QM (Ref. AMM TASK 28-28-33-400-001)
- Pressure switch 2QH (Ref. AMM TASK 28-28-11-400-001).
E. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
Subtask 57-17-11-740-053-A | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C ALL | |||
| 49VU | FUEL/X FEED/VALVE/MOT1 | 2QE | A12 |
| ** ON A/C NOT FOR ALL | |||
| 121VU | FUEL/CTR TK/PUMP2 SPLY | 30QA | P26 |
| 121VU | FUEL/CTR TK/PUMP1 SPLY | 29QA | P23 |
| ** ON A/C ALL | |||
| 121VU | FUEL/RFL/DFL/SPLY | 2QU | L24 |
| 121VU | FUEL/RFL/DFL/XFR/DEFUEL/VALVE | 1QU | L23 |
| 121VU | FUEL/L WING TK/PUMP2 SPLY | 7QA | N26 |
| 121VU | FUEL/L WING TK/PUMP1 SPLY | 1QA | N23 |
| 121VU | FUEL/R WING TK/PUMP2 SPLY | 8QA | Q26 |
| 121VU | FUEL/R WING TK/PUMP1 SPLY | 2QA | Q23 |
F. BITE Test
(1) Do a BITE test of the FQI system (Ref. AMM TASK 28-42-00-740-001).
(2) Do a BITE test of the FLSS system (Ref. AMM TASK 28-46-00-740-001).
Subtask 57-17-11-650-060-A Subtask 57-17-11-210-061-A (1) Do a BITE test of the FQI system (Ref. AMM TASK 28-42-00-740-001).
(2) Do a BITE test of the FLSS system (Ref. AMM TASK 28-46-00-740-001).
NOTE: Those tests are only applicable if you do a maintenance work in the center wing-box area.
H. Aircraft Maintenance Configuration
(1) If you did a fuel tank repair and there is a risk of remaining unwanted material in the tank:
(a) Start the engine and let it operate to flush the contamination from the fuel tank, (Ref. AMM TASK 71-00-00-710-003) or (Ref. AMM TASK 71-00-00-710-004).
(b) Replace the fuel filter (Ref. AMM TASK 73-11-10-920-001) after 150FH and 750FH after the major tank repair.
(c) For ETOPS only, do the operational check of the air release valves (Ref. AMM TASK 28-21-00-710-008) at scheduled intervals (Refer to MPD 282100-03 for scheduled intervals).
(2) De-energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-862-002).
Subtask 57-17-11-210-062-A (1) If you did a fuel tank repair and there is a risk of remaining unwanted material in the tank:
(a) Start the engine and let it operate to flush the contamination from the fuel tank, (Ref. AMM TASK 71-00-00-710-003) or (Ref. AMM TASK 71-00-00-710-004).
(b) Replace the fuel filter (Ref. AMM TASK 73-11-10-920-001) after 150FH and 750FH after the major tank repair.
(c) For ETOPS only, do the operational check of the air release valves (Ref. AMM TASK 28-21-00-710-008) at scheduled intervals (Refer to MPD 282100-03 for scheduled intervals).
(2) De-energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-862-002).
I. Leak Inspection
(1) Do a visual inspection of the access cover 148AZ and at the ACT-equipment support door.
(2) Make sure that there are no leaks.
5. Close-up(1) Do a visual inspection of the access cover 148AZ and at the ACT-equipment support door.
(2) Make sure that there are no leaks.
Subtask 57-17-11-410-055-A
A. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Remove the ground support and maintenance equipment, the special and standard tools and all other items.
(3) Remove the access platform(s).
(4) Remove the safety devices and close the Main Landing Gear (MLG) door 734 ( 744) (Ref. AMM TASK 32-12-00-410-001).
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Remove the ground support and maintenance equipment, the special and standard tools and all other items.
(3) Remove the access platform(s).
(4) Remove the safety devices and close the Main Landing Gear (MLG) door 734 ( 744) (Ref. AMM TASK 32-12-00-410-001).
Illustration of the Access Cover 148AZ