Special Detailed Inspection (US) of Center Wing Box, Triform Fitting and Stiffener between Stiffener 6 and FR 42, LH/RH
TASK 57-10-00-270-803-A
Special Detailed Inspection (US) of Center Wing Box, Triform Fitting and Stiffener between Stiffener 6 and FR 42, LH/RH
Refer to ALI TASK: 571202-02
SPECIAL DETAILED INSPECTION (US) OF CENTER WING BOX, TRIFORM FITTING AND STIFFENER BETWEEN STIFFENER 6 AND FR 42, LH/RH.
A. Fixtures, Tools, Test and Support Equipment
B. Consumable Materials
C. Work Zones and Access Panels
D. Referenced Information
3. Job Set-up
Subtask 57-10-00-010-099-A
Subtask 57-10-00-270-060-A
Subtask 57-10-00-390-057-A
[Rev.10 from 2021]
2026.04.02 06:30:32 UTC
Special Detailed Inspection (US) of Center Wing Box, Triform Fitting and Stiffener between Stiffener 6 and FR 42, LH/RH
WARNING:
PUT THE SAFETY DEVICES AND THE WARNING NOTICES IN POSITION BEFORE YOU START A TASK ON OR NEAR:
- THE FLIGHT CONTROLS
- THE FLIGHT CONTROL SURFACES
- THE LANDING GEAR AND THE RELATED DOORS
- COMPONENTS THAT MOVE.
WARNING:
BE CAREFUL WHEN YOU USE CONSUMABLE MATERIALS. OBEY THE MATERIAL MANUFACTURER'S INSTRUCTIONS AND YOUR LOCAL REGULATIONS.
ZONE: 140
1. Reason for the JobRefer to ALI TASK: 571202-02
SPECIAL DETAILED INSPECTION (US) OF CENTER WING BOX, TRIFORM FITTING AND STIFFENER BETWEEN STIFFENER 6 AND FR 42, LH/RH.
NOTE: The effectivity of this task is "ALL". To know if this task is applicable to your aircraft, refer to the MPD task applicability.
The information on weight variant groups is given in the MPD and SRM introductions.
2. Job Set-up InformationThe information on weight variant groups is given in the MPD and SRM introductions.
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | ACCESS PLATFORM 2M (6 FT) |
| No specific | AR | FLASHLIGHT |
| No specific | AR | MIRROR - INSPECTION |
| REFERENCE | DESIGNATION |
|---|---|
| (Material No.08BAA9) | Non Aqueous Cleaner-General - - |
| (Material No.14SBA1) | Textile-Lint free Cotton - |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 140 | CENTER WING |
| 734, 744 |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 32-12-00-010-001-A | Open the Main Gear Doors for Access |
| TASK 32-12-00-410-001-A | Close the Main Gear Doors after Access |
| TASK 57-17-11-000-001-A | Removal of Access Cover 147AZ(148AZ) |
| TASK 57-17-11-000-001-B | Removal of Access Cover 148AZ or/and the ACT-Equipment Support Door |
| TASK 57-17-11-400-001-A | Installation of Access Cover 147AZ(148AZ) |
| TASK 57-17-11-400-001-B | Installation of Access Cover 148AZ or/and the ACT-Equipment Support-Door |
| SRM 512300 | |
| SRM 512400 | |
| NTM 571202 | |
| SRM 511100 | (for corrective action) |
| SRM 512200 | (for corrective action) |
Triform Fitting and Stiffener of the Center Wing Box, between Stiffener 6 and FR42 ** ON A/C NOT FOR ALL | |
Triform Fitting and Stiffener of the Center Wing Box, between Stiffener 6 and FR42 ** ON A/C NOT FOR ALL | |
Subtask 57-10-00-010-099-A
A. Get Access
(1) Open the Main Landing Gear (MLG) door 734 ( 744) (Ref. AMM TASK 32-12-00-010-001).
(2) Put an ACCESS PLATFORM 2M (6 FT) in position in zone 147 (148).
(3) Remove the necessary access covers or/and ACT-equipment support door to get access to the inspection areas (Ref. AMM TASK 57-17-11-000-001).
Subtask 57-10-00-110-087-A (1) Open the Main Landing Gear (MLG) door 734 ( 744) (Ref. AMM TASK 32-12-00-010-001).
(2) Put an ACCESS PLATFORM 2M (6 FT) in position in zone 147 (148).
(3) Remove the necessary access covers or/and ACT-equipment support door to get access to the inspection areas (Ref. AMM TASK 57-17-11-000-001).
B. Preparation of the Inspection Area
(1) Remove the sealant and/or paint from the inspection area if this is necessary for the Non-destructive Testing Manual (NTM) task.
(2) Make sure that the inspection area is sufficiently clean to do a satisfactory inspection of the area.
(3) If it is not sufficiently clean, clean the inspection area with Non Aqueous Cleaner-General - - (Material No.08BAA9) and Textile-Lint free Cotton - (Material No.14SBA1) .
(4) Use a FLASHLIGHT and a MIRROR - INSPECTION for the inspection, if necessary.
4. Procedure(1) Remove the sealant and/or paint from the inspection area if this is necessary for the Non-destructive Testing Manual (NTM) task.
(2) Make sure that the inspection area is sufficiently clean to do a satisfactory inspection of the area.
(3) If it is not sufficiently clean, clean the inspection area with Non Aqueous Cleaner-General - - (Material No.08BAA9) and Textile-Lint free Cotton - (Material No.14SBA1) .
(4) Use a FLASHLIGHT and a MIRROR - INSPECTION for the inspection, if necessary.
Subtask 57-10-00-270-060-A
A. Inspection
Triform Fitting and Stiffener of the Center Wing Box, between Stiffener 6 and FR42 ** ON A/C NOT FOR ALL
Triform Fitting and Stiffener of the Center Wing Box, between Stiffener 6 and FR42 ** ON A/C NOT FOR ALL
(1) Do a special detailed inspection (US) of the triform fitting and the stringer of the center wing box for damage or discontinuities. This inspection includes the area between stiffener 6 and FR42. Do this inspection on the left and right sides on the bottom center tank from inside the aircraft. Refer to the Non-destructive Testing Manual ( NTM 571202).
(2) Make a report of the damage after the NTM inspection:
(a) Corrosion damage:
5. Close-up
Triform Fitting and Stiffener of the Center Wing Box, between Stiffener 6 and FR42 ** ON A/C NOT FOR ALL
Triform Fitting and Stiffener of the Center Wing Box, between Stiffener 6 and FR42 ** ON A/C NOT FOR ALL (2) Make a report of the damage after the NTM inspection:
(a) Corrosion damage:
- If you find corrosion, refer to the Structural Repair Manual ( SRM 512200) for the corrosion types, inspection, removal and subsequent corrosion protection.
- If you find this type of damage, refer to the Structural Repair Manual ( SRM 511100) for the damage types, classification and corrective action.
Subtask 57-10-00-390-057-A
A. Sealant or Paint Application
(1) If the NTM procedure asked to remove the sealant and/or paint from the inspection area, apply sealant (refer to SRM 512400) or paint (refer to SRM 512300) on the inspection area.
Subtask 57-10-00-410-100-A (1) If the NTM procedure asked to remove the sealant and/or paint from the inspection area, apply sealant (refer to SRM 512400) or paint (refer to SRM 512300) on the inspection area.
B. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Install the access covers or/and ACT-equipment support door (Ref. AMM TASK 57-17-11-400-001).
(3) Remove the access platform(s).
(4) Close the Main Landing Gear (MLG) door 734 ( 744) (Ref. AMM TASK 32-12-00-410-001).
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Install the access covers or/and ACT-equipment support door (Ref. AMM TASK 57-17-11-400-001).
(3) Remove the access platform(s).
(4) Close the Main Landing Gear (MLG) door 734 ( 744) (Ref. AMM TASK 32-12-00-410-001).