Special Detailed Inspection (HFEC) of Center Wing Box at Ends of Lower Skin Stiffeners, 8 to 15, LH/RH
TASK 57-10-00-250-804-A
Special Detailed Inspection (HFEC) of Center Wing Box at Ends of Lower Skin Stiffeners, 8 to 15, LH/RH
Refer to the MPD TASK: 571106-09
SPECIAL DETAILED INSPECTION (HFEC) OF CENTER WING BOX AT ENDS OF LOWER SKIN STIFFENERS, 8 TO 15, LH/RH.
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Consumable Materials
C. Work Zones and Access Panels
D. Referenced Information
3. Job Set-up
Subtask 57-10-00-010-102-A ** ON A/C NOT FOR ALL
Subtask 57-10-00-250-063-A ** ON A/C NOT FOR ALL
Subtask 57-10-00-410-103-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.02 06:30:32 UTC
Special Detailed Inspection (HFEC) of Center Wing Box at Ends of Lower Skin Stiffeners, 8 to 15, LH/RH
WARNING:
PUT THE SAFETY DEVICES AND THE WARNING NOTICES IN POSITION BEFORE YOU START A TASK ON OR NEAR:
- THE FLIGHT CONTROLS
- THE FLIGHT CONTROL SURFACES
- THE LANDING GEAR AND THE RELATED DOORS
- COMPONENTS THAT MOVE.
WARNING:
BE CAREFUL WHEN YOU USE CONSUMABLE MATERIALS. OBEY THE MATERIAL MANUFACTURER'S INSTRUCTIONS AND YOUR LOCAL REGULATIONS.
1. Reason for the JobRefer to the MPD TASK: 571106-09
SPECIAL DETAILED INSPECTION (HFEC) OF CENTER WING BOX AT ENDS OF LOWER SKIN STIFFENERS, 8 TO 15, LH/RH.
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE |
| No specific | 1 | FLASHLIGHT |
| REFERENCE | DESIGNATION |
|---|---|
| (Material No.08BAA9) | Non Aqueous Cleaner-General - - |
| (Material No.14SBA1) | Textile-Lint free Cotton - |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 141 | WING CENTER BOX |
| 142 | WING CENTER BOX |
| 147 | MAIN GEAR WELL AND HYDRAULIC COMPARTMENT |
| 148 | MAIN GEAR WELL AND HYDRAULIC COMPARTMENT |
| 147AZ, 148AZ, 734, 744 |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 32-12-00-010-001-A | Open the Main Gear Doors for Access |
| TASK 32-12-00-410-001-A | Close the Main Gear Doors after Access |
| TASK 57-17-11-000-001-A | Removal of Access Cover 147AZ(148AZ) |
| TASK 57-17-11-400-001-A | Installation of Access Cover 147AZ(148AZ) |
| NTM 571106 | |
| SRM 511100 | (for corrective action) |
| SRM 512200 | (for corrective action) |
| SRM 512300 | (for corrective action) |
| SRM 512400 | (for corrective action) |
Subtask 57-10-00-010-102-A ** ON A/C NOT FOR ALL
A. Get Access
(1) Open MLG door 734 ( 744) (Ref. AMM TASK 32-12-00-010-001).
(2) Put the ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE in position at zone 147 (148).
(3) Remove access cover 147AZ ( 148AZ) (Ref. AMM TASK 57-17-11-000-001).
(4) If installed, remove the protective cover (Ref. AMM D/O 57-17-11-00).
(5) Use the FLASHLIGHT for the inspection, if necessary.
Subtask 57-10-00-110-090-A ** ON A/C NOT FOR ALL (1) Open MLG door 734 ( 744) (Ref. AMM TASK 32-12-00-010-001).
(2) Put the ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE in position at zone 147 (148).
(3) Remove access cover 147AZ ( 148AZ) (Ref. AMM TASK 57-17-11-000-001).
(4) If installed, remove the protective cover (Ref. AMM D/O 57-17-11-00).
(5) Use the FLASHLIGHT for the inspection, if necessary.
B. Preparation of the Inspection Area
(1) Make sure that the inspection area is sufficiently clean to do a satisfactory inspection of the area.
(2) If not, clean the inspection area with Non Aqueous Cleaner-General - - (Material No.08BAA9) and the Textile-Lint free Cotton - (Material No.14SBA1) .
(3) Remove the sealant and/or paint from the inspection area if this is necessary to do the Non-destructive Testing Manual (NTM) task.
4. Procedure(1) Make sure that the inspection area is sufficiently clean to do a satisfactory inspection of the area.
(2) If not, clean the inspection area with Non Aqueous Cleaner-General - - (Material No.08BAA9) and the Textile-Lint free Cotton - (Material No.14SBA1) .
(3) Remove the sealant and/or paint from the inspection area if this is necessary to do the Non-destructive Testing Manual (NTM) task.
Subtask 57-10-00-250-063-A ** ON A/C NOT FOR ALL
A. Inspection
(1) Do a special detailed inspection (High Frequency Eddy Current (HFEC) method) of the right and left center wing-box at the ends of lower skin stiffeners 8 to 15, for damage or discontinuities. Refer to NTM 571106.
(2) Make a report of the damage after the NTM inspection:
(a) Corrosion damage:
If you find corrosion, refer to the Structural Repair Manual (Ref. SRM 512200) for the corrosion types, inspection, removal and subsequent corrosion protection.
(b) Other damage (scratches, cracks, gouges, dents, creases):
If you find this type of damage, refer to the Structural Repair Manual (Ref. SRM 511100) for damage types, classification and corrective action.
Subtask 57-10-00-910-052-A ** ON A/C NOT FOR ALL (1) Do a special detailed inspection (High Frequency Eddy Current (HFEC) method) of the right and left center wing-box at the ends of lower skin stiffeners 8 to 15, for damage or discontinuities. Refer to NTM 571106.
(2) Make a report of the damage after the NTM inspection:
(a) Corrosion damage:
If you find corrosion, refer to the Structural Repair Manual (Ref. SRM 512200) for the corrosion types, inspection, removal and subsequent corrosion protection.
(b) Other damage (scratches, cracks, gouges, dents, creases):
If you find this type of damage, refer to the Structural Repair Manual (Ref. SRM 511100) for damage types, classification and corrective action.
B. Sealant or Paint Application
(1) If the NTM procedure asked to remove the sealant and/or paint from the inspection area, apply sealant (Refer to SRM 512400) or paint (Refer to SRM 512300) on the inspection area.
5. Close-up(1) If the NTM procedure asked to remove the sealant and/or paint from the inspection area, apply sealant (Refer to SRM 512400) or paint (Refer to SRM 512300) on the inspection area.
Subtask 57-10-00-410-103-A ** ON A/C NOT FOR ALL
A. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Install access cover 147AZ ( 148AZ) (Ref. AMM TASK 57-17-11-400-001).
(3) If removed, install the protective cover (Ref. AMM D/O 57-17-11-00).
(4) Remove the access platform(s).
(5) Close MLG door 734 ( 744) (Ref. AMM TASK 32-12-00-410-001).
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Install access cover 147AZ ( 148AZ) (Ref. AMM TASK 57-17-11-400-001).
(3) If removed, install the protective cover (Ref. AMM D/O 57-17-11-00).
(4) Remove the access platform(s).
(5) Close MLG door 734 ( 744) (Ref. AMM TASK 32-12-00-410-001).
Lower Skin Stiffener 8 to 15 of the Center Wing Box