Detailed Inspection of Center Wing Box, Stringer Web at Junction with Strut Attach Fittings on Upper Stringers 2, 3, 8, 9, 15, 16
TASK 57-10-00-220-805-A
Detailed Inspection of Center Wing Box, Stringer Web at Junction with Strut Attach Fittings on Upper Stringers 2, 3, 8, 9, 15, 16
Refer to the MPD TASK: 571189-09
DETAILED INSPECTION OF CENTER WING BOX, STRINGER WEB AT JUNCTION WITH STRUT ATTACH FITTINGS ON UPPER STRINGERS 2, 3, 8, 9, 15, 16.
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Consumable Materials
C. Work Zones and Access Panels
D. Referenced Information
3. Job Set-up
Subtask 57-10-00-010-103-A ** ON A/C NOT FOR ALL
Subtask 57-10-00-220-066-A ** ON A/C NOT FOR ALL
Subtask 57-10-00-410-104-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.02 06:30:32 UTC
Detailed Inspection of Center Wing Box, Stringer Web at Junction with Strut Attach Fittings on Upper Stringers 2, 3, 8, 9, 15, 16
WARNING:
PUT THE SAFETY DEVICES AND THE WARNING NOTICES IN POSITION BEFORE YOU START A TASK ON OR NEAR:
- THE FLIGHT CONTROLS
- THE FLIGHT CONTROL SURFACES
- THE LANDING GEAR AND THE RELATED DOORS
- COMPONENTS THAT MOVE.
WARNING:
BE CAREFUL WHEN YOU USE CONSUMABLE MATERIALS. OBEY THE MATERIAL MANUFACTURER'S INSTRUCTIONS AND YOUR LOCAL REGULATIONS.
1. Reason for the JobRefer to the MPD TASK: 571189-09
DETAILED INSPECTION OF CENTER WING BOX, STRINGER WEB AT JUNCTION WITH STRUT ATTACH FITTINGS ON UPPER STRINGERS 2, 3, 8, 9, 15, 16.
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE |
| No specific | 1 | FLASHLIGHT |
| REFERENCE | DESIGNATION |
|---|---|
| (Material No.08BAA9) | Non Aqueous Cleaner-General - - |
| (Material No.14SBA1) | Textile-Lint free Cotton - |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 141 | WING CENTER BOX |
| 142 | WING CENTER BOX |
| 147 | MAIN GEAR WELL AND HYDRAULIC COMPARTMENT |
| 148 | MAIN GEAR WELL AND HYDRAULIC COMPARTMENT |
| 147AZ, 148AZ, 734, 744 |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 32-12-00-010-001-A | Open the Main Gear Doors for Access |
| TASK 32-12-00-410-001-A | Close the Main Gear Doors after Access |
| TASK 57-17-11-000-001-A | Removal of Access Cover 147AZ(148AZ) |
| TASK 57-17-11-400-001-A | Installation of Access Cover 147AZ(148AZ) |
| SRM 511100 | (for corrective action) |
| SRM 512200 | (for corrective action) |
Subtask 57-10-00-010-103-A ** ON A/C NOT FOR ALL
A. Get Access
(1) Open MLG door 734 ( 744) (Ref. AMM TASK 32-12-00-010-001).
(2) Put the ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE in position at zone 147 (148).
(3) Remove access cover 147AZ ( 148AZ) (Ref. AMM TASK 57-17-11-000-001).
(4) Use the FLASHLIGHT for the inspection, if necessary.
Subtask 57-10-00-110-091-A ** ON A/C NOT FOR ALL (1) Open MLG door 734 ( 744) (Ref. AMM TASK 32-12-00-010-001).
(2) Put the ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE in position at zone 147 (148).
(3) Remove access cover 147AZ ( 148AZ) (Ref. AMM TASK 57-17-11-000-001).
(4) Use the FLASHLIGHT for the inspection, if necessary.
B. Preparation of the Inspection Area
(1) Make sure that the inspection area is sufficiently clean to do a satisfactory inspection of the area.
(2) If not, clean the inspection area with Non Aqueous Cleaner-General - - (Material No.08BAA9) and the Textile-Lint free Cotton - (Material No.14SBA1) .
4. Procedure(1) Make sure that the inspection area is sufficiently clean to do a satisfactory inspection of the area.
(2) If not, clean the inspection area with Non Aqueous Cleaner-General - - (Material No.08BAA9) and the Textile-Lint free Cotton - (Material No.14SBA1) .
Subtask 57-10-00-220-066-A ** ON A/C NOT FOR ALL
A. Inspection
(1) Do a detailed inspection of the stringer web at the junction with the strut attach fittings for damage or discontinuities. This inspection is applicable at stringers 2, 3, 8, 9, 15 and 16 of the center wing box.
(2) Make sure that there is no:
(a) Corrosion damage:
If you find corrosion, refer to the Structural Repair Manual ( SRM 512200) for the corrosion types, inspection, removal and subsequent corrosion protection.
(b) Other damage (scratches, cracks, gouges, dents, creases):
If you find this type of damage, refer to the Structural Repair Manual ( SRM 511100) for the damage types, classification and corrective action.
5. Close-up(1) Do a detailed inspection of the stringer web at the junction with the strut attach fittings for damage or discontinuities. This inspection is applicable at stringers 2, 3, 8, 9, 15 and 16 of the center wing box.
(2) Make sure that there is no:
(a) Corrosion damage:
If you find corrosion, refer to the Structural Repair Manual ( SRM 512200) for the corrosion types, inspection, removal and subsequent corrosion protection.
(b) Other damage (scratches, cracks, gouges, dents, creases):
If you find this type of damage, refer to the Structural Repair Manual ( SRM 511100) for the damage types, classification and corrective action.
Subtask 57-10-00-410-104-A ** ON A/C NOT FOR ALL
A. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Install access cover 147AZ ( 148AZ) (Ref. AMM TASK 57-17-11-400-001).
(3) Remove the access platform(s).
(4) Close MLG door 734 ( 744) (Ref. AMM TASK 32-12-00-410-001).
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Install access cover 147AZ ( 148AZ) (Ref. AMM TASK 57-17-11-400-001).
(3) Remove the access platform(s).
(4) Close MLG door 734 ( 744) (Ref. AMM TASK 32-12-00-410-001).
Stringer Web at the Junction with the Strut Attach Fittings on the Upper Stringers 2, 3, 8, 9, 15, 16 of the Center Wing Box