W DOC AIRBUS | AMM A320F

Detailed Inspection of the Center Wing Box, Rear Spar, Around Access Door Cutouts


TASK 57-10-00-200-004-A
Detailed Inspection of the Center Wing Box, Rear Spar, Around Access Door Cutouts


WARNING: BE CAREFUL WHEN YOU USE CONSUMABLE MATERIALS. OBEY THE MATERIAL MANUFACTURER'S INSTRUCTIONS AND YOUR LOCAL REGULATIONS.
CAUTION: DO NOT APPLY TEMPORARY PROTECTION SYSTEM (TPS) ON THE INSPECTION AREA. IF YOU APPLY TPS ON THE INSPECTION AREA, YOU CAN CAUSE DAMAGE TO THE AIRCRAFT.
ZONE: 147
ZONE: 148
1. Reason for the Job
Refer to the MPD TASK: 571109-01
DETAILED INSPECTION OF CENTER WING BOX, REAR SPAR, AROUND ACCESS DOOR CUTOUTS
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
AR
LIGHT SOURCE - TORCH
 B. Consumable Materials
REFERENCE
DESIGNATION
(Material No.08BAA9)
Non Aqueous Cleaner-General - -
(Material No.14SBA1)
Textile-Lint free Cotton -
 C. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
147
MAIN GEAR WELL AND HYDRAULIC COMPARTMENT
148
MAIN GEAR WELL AND HYDRAULIC COMPARTMENT
 D. Referenced Information
REFERENCE
DESIGNATION
TASK 51-78-00-916-001-A
Application of Temporary Protection System (TPS)
TASK 57-17-11-000-001-A
Removal of Access Cover 147AZ(148AZ)
TASK 57-17-11-000-001-B
Removal of Access Cover 148AZ or/and the ACT-Equipment Support Door
TASK 57-17-11-400-001-A
Installation of Access Cover 147AZ(148AZ)
TASK 57-17-11-400-001-B
Installation of Access Cover 148AZ or/and the ACT-Equipment Support-Door
SRM 511100
SRM 512200
3. Job Set-up
Subtask 57-10-00-010-053-A
A. Get Access
   (1) Remove the necessary access cover(s) or/and ACT-equipment support door to get access to the inspection areas (Ref. AMM TASK 57-17-11-000-001).
   (2) Use a LIGHT SOURCE - TORCH for the inspection.
Subtask 57-10-00-110-063-A
B. Preparation of the Inspection Area
   (1) Make sure that the inspection area is sufficiently clean to do a satisfactory inspection of the area.
   (2) If it is not, clean the inspection area with Non Aqueous Cleaner-General - - (Material No.08BAA9) and a Textile-Lint free Cotton - (Material No.14SBA1) .
   (3) Make sure that there is no Temporary Protection System (TPS) layer and if there is a TPS layer, remove it (Ref. AMM TASK 51-78-00-916-001).
4. Procedure
Subtask 57-10-00-220-050-A
A. Inspection
   (1) Do a detailed visual inspection of the rear spar of the center wing box around the access door cutouts.
   (2) Make sure that there is no:
     (a) Corrosion damage:
  • If you find corrosion damage, refer to the Structural Repair Manual SRM 512200 for types, inspection, removal and corrosion protection.
     (b) Other damage (scratches, cracks, gouges, dents, creases):
  • If you find this type of damage, refer to the Structural Repair Manual SRM 511100 for damage classification and corrective action.
5. Close-up
Subtask 57-10-00-410-053-A
A. Close Access
   (1) Install the access cover(s) or/and ACT-equipment support door (Ref. AMM TASK 57-17-11-400-001).
   (2) Make sure that the work area is clean and clear of tools and other items.
[Rev.10 from 2021] 2026.04.02 06:30:29 UTC