W DOC AIRBUS | AMM A320F

Installation of the Fixed Windows


TASK 56-11-12-400-002-A
Installation of the Fixed Windows


WARNING: YOU MUST MAKE SURE THAT YOU CAN HOLD THE COMPONENT BEFORE YOU REMOVE/INSTALL IT. THE COMPONENT IS HEAVY. IF IT FALLS, IT CAN CAUSE INJURY TO PERSONS AND DAMAGE TO EQUIPMENT.
WARNING: BE CAREFUL WHEN YOU USE CONSUMABLE MATERIALS. OBEY THE MATERIAL MANUFACTURER'S INSTRUCTIONS AND YOUR LOCAL REGULATIONS.
CAUTION: DO NOT USE SHARP AND/OR METALLIC TOOLS OR OBJECTS TO REMOVE/INSTALL THE WINDSHIELD OR A WINDOW. DO NOT USE A LEVER AGAINST THE EDGE OF THE WINDSHIELD OR WINDOW. IF YOU DO NOT OBEY THESE INSTRUCTIONS, YOU WILL CAUSE DAMAGE TO THE WINDSHIELD OR WINDOW.
ZONE: 211
ZONE: 212
FIN: 7DG1
FIN: 7DG2
1. Reason for the Job
NOTE: Two persons are necessary for this procedure.
NOTE: This procedure is applicable to:
  • The acrylic fixed windows (GKN supplier, P/N NH...)
  • The glass fixed windows (PPG supplier, P/N NP...)
  • The glass fixed windows (SGS supplier, P/Ns SPSA320-9-X-X and SPSA320-10-X-X only).
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
AR
ACCESS PLATFORM 5M (16 FT)- ADJUSTABLE
No specific
Torque wrench: range to between 1.8 and 1.6 m.daN (13.27 and 11.80 lbf.ft ) T
 B. Consumable Materials
REFERENCE
DESIGNATION
(Material No.05RAB9)
Adhesive Film Tape-- Aluminium Foil -
(Material No.06ABF1)
Polysulfide Sealant-Fuel Tank Quick Curing -
(Material No.06BEC1)
Silicone Sealant-Windshield Two parts Quick Curing -
(Material No.06LCG9)
Non Hardening Jointing Putty-Medium Temp. Area - -
(Material No.08BBB1)
Non Aqueous Cleaner-- Petroleum Based -
(Material No.08BPA1)
Non Aqueous Cleaner-Non structural use - -
(Material No.14SBA1)
Textile-Lint free Cotton -
 C. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
211
COCKPIT
212
COCKPIT
FOR [7DG1] (WINDOW-FIXED, L)
211KW
FOR [7DG2] (WINDOW-FIXED, R)
212KW
 D. Referenced Information
REFERENCE
DESIGNATION
TASK 30-42-00-710-001-A
Operational Test of the Windshield Anti-Icing and Defogging
TASK 56-10-00-110-002-A
Cleaning of the L/R Fixed Windows
ASM 304201
ASM 304202
3. Job Set-up
Subtask 56-11-12-869-051-A
A. Aircraft Maintenance Configuration
   (1) Make sure that the ACCESS PLATFORM 5M (16 FT)- ADJUSTABLE is in position at zone 210.
Subtask 56-11-12-865-051-A
WARNING: MAKE SURE THAT THE CIRCUIT BREAKERS RELATED TO THE WEATHER RADAR ARE OPENED, SAFETIED AND TAGGED.
B. Make sure that this(these) circuit breaker(s) is(are) open, safetied and tagged:
PANELDESIGNATIONFINLOCATION
** ON A/C ALL
121VUCOM NAV/RADAR/15SQ1K13
** ON A/C NOT FOR ALL
121VUCOM NAV/RADAR/25SQ2K14
** ON A/C ALL
FOR FIN: 7DG1 (WINDOWFIXED, L)
122VUANTI ICE/WINDOWS/L4DG1X14
122VUANTI ICE/WHC/15DG1X13
123VUANTI ICE/L/WHSLD1DG1AF10
FOR FIN: 7DG2 (WINDOWFIXED, R)
122VUANTI ICE/WINDOWS/R4DG2W14
122VUANTI ICE/WHC/25DG2W13
123VUANTI ICE/R/WHSLD1DG2AF03
Subtask 56-11-12-914-058-A
C. Preparation for the Installation
   (1) Clean the housing of the fixed window with Non Aqueous Cleaner-- Petroleum Based - (Material No.08BBB1) and the Textile-Lint free Cotton - (Material No.14SBA1) .
4. Procedure
Subtask 56-11-12-420-050-A
A. Installation of the Fixed Window Assembly
   (1) Put the fixed window assembly (13) in position in its housing.
   (2) Apply Non Hardening Jointing Putty-Medium Temp. Area - - (Material No.06LCG9) in the housings of the heads of the screws (12).
   (3) Install the screws (12).
     (a) Do not torque them at this time.
   (4) Remove the CAP-BLANKING from each electrical connector and receptacle.
   (5) Make sure that pins A/C and A/D of the sensor (11) are connected to pins B/V and B/U of the window heat computer ASM 304201 or ASM 304202.
   (6) Connect the sensor (11) to the receptacle (14).
Subtask 56-11-12-820-057-A
B. Adjustment of the Fixed Window
   (1) Adjust the fixed window in its housing to get:
     (a) The value of peripheral clearance J1 (between the retainer and the frame) on the measured points that agrees with the value given in the related figure for:
NOTE: Peripheral clearance J1 of between 0.4 mm (0.0157 in.) and 3 mm (0.1181 in.) is permitted on the measured points for all the fixed windows.
     (b) Peripheral clearance J2 (between the retainer and the frame) of 0.7 mm (0.0276 in.) minimum.
Subtask 56-11-12-420-060-A
C. Torque of the Fixed Window Fasteners
   (1) TORQUE the screws (12) to between 1.8 and 1.6 m.daN (13.27 and 11.80 lbf.ft ) T in the attachment holes in the sequence given in the figure.
Subtask 56-11-12-820-058-A
D. Check of the Clearances
   (1) Make sure that the values of out-of-flush dimensions A1 and A2 (between the retainer and the frame) on the measured points agree with the values given in the related figure for:
NOTE: Out-of-flush dimensions A1 and A2 of between -1 mm (-0.0394 in.) and 1 mm (0.0394 in.) are permitted on the measured points for all the fixed windows.
Subtask 56-11-12-914-051-A
E. Sealant Application
   (1) Apply a bead of Polysulfide Sealant-Fuel Tank Quick Curing - (Material No.06ABF1) or Silicone Sealant-Windshield Two parts Quick Curing - (Material No.06BEC1) at the intersection between the retainers and the structure to fill the remaining spaces.
NOTE: You can use PR1436B, DAPCO 72, PR1826B or PR1828B. The sealant cure time and the mixing ratio are given in the sealant-kit manufacturer instructions.
NOTE: The primers related to the sealants help to get a better bond. These primers are mandatory and it is necessary to apply them before the related sealants.
   (2) If there is not sufficient time for the sealant to cure before the aircraft takes off, do the procedure that follows:
CAUTION: BEFORE YOU APPLY THE TAPE, MAKE SURE THAT THE SEALANT IS NOT TACKY. IF IT IS TACKY, THE TAPE CAN CAUSE DAMAGE TO THE SEALANT.
CAUTION: WHEN YOU APPLY THE TAPE, MAKE SURE THAT THERE ARE NO BUBBLES. THIS WILL HELP TO PREVENT THE REMOVAL OF THE TAPE DURING FLIGHT.
     (a) Put a strip of Adhesive Film Tape-- Aluminium Foil - (Material No.05RAB9) on the intersection areas.
     (b) Do a visual check of the Adhesive Film Tape-- Aluminium Foil - (Material No.05RAB9) after each flight.
     (c) Remove the Adhesive Film Tape-- Aluminium Foil - (Material No.05RAB9) after the sealant cure time.
NOTE: During the flight, the temperatures are less than 10 deg. C and the sealant does not dry. The flight hours are not included in the sealant cure time.
   (3) Remove the remaining sealant from the intersection areas and make sure that the bead of sealant is continuous.
   (4) Clean the external surfaces of the structure with Non Aqueous Cleaner-Non structural use - - (Material No.08BPA1) and the Textile-Lint free Cotton - (Material No.14SBA1) .
Subtask 56-11-12-420-059-A
F. Installation of the Lining Panels
   (1) Put the lining panel (8) in position.
   (2) Tighten the fasteners (2).
   (3) Install the washers (7) and the screws (6).
   (4) Tighten the screws (6).
   (5) Install the lateral lining panels:
     (a) FOR [7DG1] (WINDOW-FIXED, L)
  • Put panel (5) 211KW in position.
  • Tighten the fasteners (4).
  • Install the screws (3) and tighten them.
     (b) FOR [7DG2] (WINDOW-FIXED, R)
  • Put panel 212KW in position.
  • Tighten the fasteners (1).
Subtask 56-11-12-865-052-A
G. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C ALL
121VUCOM NAV/RADAR/15SQ1K13
** ON A/C NOT FOR ALL
121VUCOM NAV/RADAR/25SQ2K14
** ON A/C ALL
122VUANTI ICE/WINDOWS/R4DG2W14
122VUANTI ICE/WHC/25DG2W13
122VUANTI ICE/WINDOWS/L4DG1X14
122VUANTI ICE/WHC/15DG1X13
123VUANTI ICE/L/WHSLD1DG1AF10
123VUANTI ICE/R/WHSLD1DG2AF03
Subtask 56-11-12-710-050-A
H. Test
   (1) Do an operational test of the anti-ice and defogging system of the fixed windows (Ref. AMM TASK 30-42-00-710-001).
5. Close-up
Subtask 56-11-12-110-051-A
A. Cleaning
   (1) Clean the fixed windows (Ref. AMM TASK 56-10-00-110-002).
Subtask 56-11-12-942-050-A
B. Close Access
   (1) Make sure that the work area is clean and clear of tools and other items.
   (2) Remove the ground support and maintenance equipment, the special and standard tools and all other items.
   (3) Remove the access platform(s).
[Rev.10 from 2021] 2026.04.01 02:07:05 UTC