W DOC AIRBUS | AMM A320F

Removal of the Fixed Windows


TASK 56-11-12-000-002-A
Removal of the Fixed Windows


WARNING: YOU MUST MAKE SURE THAT YOU CAN HOLD THE COMPONENT BEFORE YOU REMOVE/INSTALL IT. THE COMPONENT IS HEAVY. IF IT FALLS, IT CAN CAUSE INJURY TO PERSONS AND DAMAGE TO EQUIPMENT.
CAUTION: DO NOT USE SHARP AND/OR METALLIC TOOLS OR OBJECTS TO REMOVE/INSTALL THE WINDSHIELD OR A WINDOW. DO NOT USE A LEVER AGAINST THE EDGE OF THE WINDSHIELD OR WINDOW. IF YOU DO NOT OBEY THESE INSTRUCTIONS, YOU WILL CAUSE DAMAGE TO THE WINDSHIELD OR WINDOW.
ZONE: 211
ZONE: 212
FIN: 7DG1
FIN: 7DG2
1. Reason for the Job
NOTE: Two persons are necessary for this procedure.
NOTE: This procedure is only applicable to the glass fixed windows (SGS supplier P/Ns SPSA320-5-X-X and SPSA320-6-X-X).
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
AR
ACCESS PLATFORM 5M (16 FT)- ADJUSTABLE
No specific
AR
CAP - BLANKING
No specific
AR
SAFETY CLIP - CIRCUIT BREAKER
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
211
COCKPIT
212
COCKPIT
FOR [7DG1] (WINDOW-FIXED, L)
211KW
FOR [7DG2] (WINDOW-FIXED, R)
212KW
 C. Referenced Information
REFERENCE
DESIGNATION
3. Job Set-up
Subtask 56-11-12-941-058-A
A. Get Access
   (1) Put the ACCESS PLATFORM 5M (16 FT)- ADJUSTABLE in position at zone 210, in front of the fixed window.
Subtask 56-11-12-865-067-A
B. Open, safety and tag this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C ALL
FOR FIN: 7DG1 (WINDOWFIXED, L)
122VUANTI ICE/WINDOWS/L4DG1X14
122VUANTI ICE/WHC/15DG1X13
123VUANTI ICE/L/WHSLD1DG1AF10
FOR FIN: 7DG2 (WINDOWFIXED, R)
122VUANTI ICE/WINDOWS/R4DG2W14
122VUANTI ICE/WHC/25DG2W13
123VUANTI ICE/R/WHSLD1DG2AF03
4. Procedure
Subtask 56-11-12-020-053-A
A. Removal of the Fixed Window Assembly
   (1) Removal of the lining panel (8):
     (a) Remove the lateral lining panel:
       1 FOR [7DG1] (WINDOW-FIXED, L)
  • Remove the screws (3).
  • Loosen the fasteners (4).
  • Remove panel 211KW (5).
       2 FOR [7DG2] (WINDOW-FIXED, R)
  • Loosen the fasteners (1).
  • Remove panel 212KW.
     (b) Remove the screws (6) and the washers (7).
     (c) Loosen the fasteners (2).
     (d) Remove the lining panel (8).
   (2) Removal of the fixed window assembly:
     (a) Disconnect the sensor (11) from the receptacle (14).
     (b) Install the CAP - BLANKING on the disconnected electrical connector.
     (c) Remove the screws (12).
     (d) Remove the fixed window assembly (13).
Subtask 56-11-12-020-054-A
B. Disassembly of the Fixed Window Assembly
   (1) Loosen the 45 bolts (15) and the 45 nuts (17).
   (2) Remove and discard the nuts (17).
   (3) Remove the inner retainer (18).
   (4) Remove the fixed window panel (19) and the seal (20) from the outer retainer (21).
   (5) Remove the 45 bolts (15).
[Rev.10 from 2021] 2026.04.01 02:07:06 UTC