1. Reason for the Job
Refer to the MPD TASK: 535900-02
OPERATIONAL CHECK OF RUBBER FLAP DRAIN VALVE AT BULK CARGO COMPARTMENT DOOR FROM OUTSIDE
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
1
ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE
No specific
1
PROBE DIA LESS THAN 5 MM(0.197IN)NON METALLIC FLEXIBLE
 B. Consumable Materials
REFERENCE
DESIGNATION
(Material No.14SBA1)
Textile-Lint free Cotton -
 C. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
827
BULK CARGO COMPARTMENT DOOR
 D. Referenced Information
REFERENCE
DESIGNATION
TASK 52-30-00-860-006-A
Open the Bulk Cargo-Compartment Door
TASK 52-30-00-860-008-A
Close the Bulk Cargo-Compartment Door
3. Job Set-up
Subtask 53-59-00-010-051-A ** ON A/C NOT FOR ALL
A. Get Access
   (1) Put the ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE in position.
   (2) Open the BULK cargo-compartment door (Ref. AMM TASK 52-30-00-860-006).
4. Procedure
Subtask 53-59-00-280-050-A ** ON A/C NOT FOR ALL
A. Specified Check Procedure
   (1) Clean the area around the drain hole with the Textile-Lint free Cotton - (Material No.14SBA1) .
   (2) Make sure that the drain hole is not blocked.
   (3) If the drain hole is blocked, you must remove the blockage.
   (4) Carefully push a PROBE DIA LESS THAN 5 MM(0.197IN)NON METALLIC FLEXIBLE through the drain hole and make sure that the rubber flap moves freely.
5. Close-up
Subtask 53-59-00-410-051-A ** ON A/C NOT FOR ALL
A. Close Access
   (1) Make sure that the work area is clean and clear of tools and other items.
   (2) Close the BULK cargo-compartment door (Ref. AMM TASK 52-30-00-860-008).
   (3) Remove the access platform(s).
[Rev.10 from 2021] 2026.04.02 06:29:30 UTC