Special Detailed Inspection (HFEC) of the Lower Flanges of FR 72 and FR 74, between STGR 10 LH and STGR 10 RH
TASK 53-51-00-220-802-A
Special Detailed Inspection (HFEC) of the Lower Flanges of FR 72 and FR 74, between STGR 10 LH and STGR 10 RH
Refer to the MPD TASK: 535163-01
SPECIAL DETAILED INSPECTION (HFEC) OF LOWER FLANGES OF FR 72 AND FR 74, BETWEEN STRINGER 10 LH AND STRINGER 10 RH.
A. Fixtures, Tools, Test and Support Equipment
B. Consumable Materials
C. Work Zones and Access Panels
D. Referenced Information
3. Job Set-up
Subtask 53-51-00-010-077-A
Subtask 53-51-00-220-050-A
Subtask 53-51-00-410-075-A
[Rev.10 from 2021]
2026.04.02 06:29:27 UTC
Special Detailed Inspection (HFEC) of the Lower Flanges of FR 72 and FR 74, between STGR 10 LH and STGR 10 RH
ZONE: 310
1. Reason for the JobRefer to the MPD TASK: 535163-01
SPECIAL DETAILED INSPECTION (HFEC) OF LOWER FLANGES OF FR 72 AND FR 74, BETWEEN STRINGER 10 LH AND STRINGER 10 RH.
NOTE: The effectivity of this task is ALL. To know, if this task is applicable for your aircraft, refer to the MPD task applicability and the weight variant data given in the SRM introduction.
2. Job Set-up InformationA. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 1 | ACCESS PLATFORM 3M (10 FT) |
| No specific | 1 | ACCESS PLATFORM 4M (13 FT)-ADJUSTABLE |
| No specific | 1 | CLOTH-EMERY (GRADE 280) |
| REFERENCE | DESIGNATION |
|---|---|
| (Material No.08BAA9) | Non Aqueous Cleaner-General - - |
| (Material No.14SBA1) | Textile-Lint free Cotton - |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 310 | FUSLG TAIL SECTION AFT OF AFT PRESS BHD |
| 312AR, 314AR |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 52-41-23-010-801-A | Opening of Access Door 314AR |
| TASK 52-41-23-410-801-A | Closing of Access Door 314AR |
| SRM 511100 | |
| SRM 512200 | |
| SRM 517300 | |
| SRM 517400 | |
| NTM 535163 | |
Subtask 53-51-00-010-077-A
A. Get Access
(2) Put the ACCESS PLATFORM 4M (13 FT)-ADJUSTABLE in position below access door 314AR.
(3) Open access door 312AR.
(4) Open access door 314AR (Ref. AMM TASK 52-41-23-010-801).
Subtask 53-51-00-110-081-A WARNING:
PUT THE SAFETY DEVICES AND THE WARNING NOTICES IN POSITION BEFORE YOU START A TASK ON OR NEAR:
(1) Put the ACCESS PLATFORM 3M (10 FT) in position below access door 312AR. - THE FLIGHT CONTROLS
- THE FLIGHT CONTROL SURFACES
- THE LANDING GEAR AND THE RELATED DOORS
- COMPONENTS THAT MOVE.
(2) Put the ACCESS PLATFORM 4M (13 FT)-ADJUSTABLE in position below access door 314AR.
(3) Open access door 312AR.
(4) Open access door 314AR (Ref. AMM TASK 52-41-23-010-801).
B. Preparation of the Inspection Area
(1) Make sure that the inspection area is sufficiently clean to do a satisfactory inspection of the area.
(3) Make sure that the inspection area is dry before you continue.
(4) Do a visual check of the inspection area for damage.
(5) If you find damage:
(a) Refer to the ASRM SRM 511100 for the classification of the damage
(b) If you find corrosion damage:
4. Procedure(1) Make sure that the inspection area is sufficiently clean to do a satisfactory inspection of the area.
WARNING:
BE CAREFUL WHEN YOU USE CONSUMABLE MATERIALS. OBEY THE MATERIAL MANUFACTURER'S INSTRUCTIONS AND YOUR LOCAL REGULATIONS.
(2) If necessary, clean the inspection area with the Non Aqueous Cleaner-General - - (Material No.08BAA9) and a Textile-Lint free Cotton - (Material No.14SBA1) . (3) Make sure that the inspection area is dry before you continue.
(4) Do a visual check of the inspection area for damage.
(5) If you find damage:
(a) Refer to the ASRM SRM 511100 for the classification of the damage
(b) If you find corrosion damage:
- Refer to the ASRM SRM 512200 for the general corrosion data.
- Refer to the ASRM SRM 517400 for the repair of the corroded areas.
Subtask 53-51-00-220-050-A
A. Special Detailed Inspection
(1) Do the special detailed inspection (HFEC) of the lower flanges of FR72 and FR74 between STGR10 LH and STGR10 RH, NTM 535163. Look for cracks.
(2) Make a report of damage during the inspection procedure.
(a) Refer to the SRM 511100 for the classification of the damage.
(b) If you find corrosion damage:
5. Close-up(1) Do the special detailed inspection (HFEC) of the lower flanges of FR72 and FR74 between STGR10 LH and STGR10 RH, NTM 535163. Look for cracks.
(2) Make a report of damage during the inspection procedure.
(a) Refer to the SRM 511100 for the classification of the damage.
(b) If you find corrosion damage:
- Refer to the SRM 512200 for the general corrosion data
- Refer to the SRM 517400 for the repair of the corroded areas.
- Refer to the SRM 517300 for the repair of minor damage.
Subtask 53-51-00-410-075-A
A. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Close access door 314AR (Ref. AMM TASK 52-41-23-410-801).
(3) Close access door 312AR.
(4) Remove the access platform(s).
(5) Remove the ground support and maintenance equipment, the special and standard tools and all other items.
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Close access door 314AR (Ref. AMM TASK 52-41-23-410-801).
(3) Close access door 312AR.
(4) Remove the access platform(s).
(5) Remove the ground support and maintenance equipment, the special and standard tools and all other items.
Inspection Areas of the Lower Flanges of FR72 and FR74, between STGR10 LH and STGR10 RH