W DOC AIRBUS | AMM A320F

General Visual Inspection of the Fuselage Internal Structure, From FR 47 to FR 70, above the Cabin Floor Level


TASK 53-41-00-210-824-A
General Visual Inspection of the Fuselage Internal Structure, From FR 47 to FR 70, above the Cabin Floor Level


WARNING: BE CAREFUL WHEN YOU USE CONSUMABLE MATERIALS. OBEY THE MATERIAL MANUFACTURER'S INSTRUCTIONS AND YOUR LOCAL REGULATIONS.
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Consumable Materials
REFERENCE
DESIGNATION
(Material No.08BAA9)
Non Aqueous Cleaner-General - -
(Material No.14SBA1)
Textile-Lint free Cotton -
 B. Referenced Information
REFERENCE
DESIGNATION
TASK 25-23-41-000-001-A
Removal of the Ceiling Panels
TASK 25-23-41-400-001-A
Installation of the Ceiling Panels
TASK 25-23-42-000-001-A
Removal of the Ceiling Panels - Forward Utility Area
TASK 25-23-42-400-001-A
Installation of the Ceiling Panels - Forward Utility Area
TASK 25-23-43-000-001-A
Removal of the Upper Sidewall Panel
TASK 25-23-43-400-001-A
Installation of the Upper Sidewall Panel
TASK 25-23-44-000-001-A
Removal of the Lower Sidewall Panels (Dado Panels)
TASK 25-23-44-400-001-A
Installation of the Lower Sidewall Panels (Dado Panels)
TASK 25-23-46-000-002-A
Removal of the Door Linings from the Aft Passenger/Crew Doors
TASK 25-23-46-400-002-A
Installation of the Door Linings on the Aft Passenger/Crew Doors
TASK 25-23-47-000-001-A
Removal of the Lining from the Emergency Exit Hatches
TASK 25-23-47-400-001-A
Installation of the Lining on the Emergency Exit Hatches
TASK 25-24-41-000-001-A
Removal of the Overhead Stowage Compartments (OHSC)
TASK 25-24-41-400-001-A
Installation of the Overhead Stowage Compartments (OHSC)
TASK 25-80-00-000-001-A
Removal of the Insulation Blankets
TASK 25-80-00-400-001-A
Installation of the Insulation Blankets
SRM 53411201
(for corrective action)
SRM 53411202
(for corrective action)
SRM 53411301
(for corrective action)
SRM 53411302
(for corrective action)
TASK 25-30-00-00
BUFFET AND GALLEY - DESCRIPTION AND OPERATION
TASK 25-40-00-00
LAVATORIES - DESCRIPTION AND OPERATION
3. Job Set-up
Subtask 53-41-00-010-159-A
A. Get Access
   (1) If the galleys and the lavatories are installed, remove them between frames 47 and 70. To do this, refer to the paragraph Component Location in the applicable ATA 25 Description/Operation:
   (2) Remove the Overhead Stowage Compartments (OHSC) (Ref. AMM TASK 25-24-41-000-001).
   (3) Remove the linings (Ref. AMM TASK 25-23-41-000-001), (Ref. AMM TASK 25-23-42-000-001), (Ref. AMM TASK 25-23-43-000-001), (Ref. AMM TASK 25-23-44-000-001), (Ref. AMM TASK 25-23-46-000-002) and (Ref. AMM TASK 25-23-47-000-001).
   (4) Remove the insulation blankets (Ref. AMM TASK 25-80-00-000-001).
Subtask 53-41-00-110-107-A
B. Clean the inspection area with Non Aqueous Cleaner-General - - (Material No.08BAA9) and a Textile-Lint free Cotton - (Material No.14SBA1) .
4. Procedure
Subtask 53-41-00-210-126-A ** ON A/C NOT FOR ALL
A. Inspection
   (1) Examine the following areas for scratches, dents and cracks:
  • the internal structure of the fuselage between FR47 and FR 70 above the cabin floor level.
NOTE: If necessary, refer to the ASRM SRM 53411201 and SRM 53411301 for the allowable damage limits.
NOTE: If necessary, refer to the ASRM SRM 53411202 and SRM 53411302 for the correct repair procedure.
Subtask 53-41-00-210-126-B ** ON A/C NOT FOR ALL
A. Inspection
   (1) Examine the following areas for scratches, dents and cracks:
  • the internal structure of the fuselage between FR47/51 and FR 70 above the cabin floor level.
NOTE: If necessary, refer to the ASRM SRM 53411201 and SRM 53411301 for the allowable damage limits.
NOTE: If necessary, refer to the ASRM SRM 53411202 and SRM 53411302 for the correct repair procedure.
5. Close-up
Subtask 53-41-00-410-156-A
A. Close Access
   (1) Make sure that the work area is clean and clear of tools and other items.
   (2) Install the insulation blankets (Ref. AMM TASK 25-80-00-400-001).
   (3) Install the linings (Ref. AMM TASK 25-23-41-400-001), (Ref. AMM TASK 25-23-42-400-001), (Ref. AMM TASK 25-23-43-400-001), (Ref. AMM TASK 25-23-44-400-001), (Ref. AMM TASK 25-23-46-400-002) and (Ref. AMM TASK 25-23-47-400-001).
   (4) Install the OHSCs (Ref. AMM TASK 25-24-41-400-001).
   (5) Install the removed galleys and lavatories between frames 47 and 70. To do this, refer to the paragraph Component Location in the applicable ATA 25 Description/Operation:
   (6) Remove the ground support and maintenance equipment, the special and standard tools and all other items.
[Rev.10 from 2021] 2026.04.02 06:29:18 UTC