W DOC AIRBUS | AMM A320F

General Visual Inspection of Cabin Floor Structure, excluding Areas below Galleys and Toilets and Door Entrance Area


TASK 53-41-00-210-801-A
General Visual Inspection of Cabin Floor Structure, excluding Areas below Galleys and Toilets and Door Entrance Area


WARNING: BE CAREFUL WHEN YOU USE CONSUMABLE MATERIALS. OBEY THE MATERIAL MANUFACTURER'S INSTRUCTIONS AND YOUR LOCAL REGULATIONS.
ZONE: 251
ZONE: 252
ZONE: 261
ZONE: 262
1. Reason for the Job
Refer to the MPD TASK: 534146-01
GENERAL VISUAL INSPECTION OF CABIN FLOOR STRUCTURE, EXCLUDING AREAS BELOW GALLEYS AND TOILETS AND DOOR ENTRANCE AREA, FROM FR 47 TO FR 70
2. Job Set-up Information
 A. Consumable Materials
REFERENCE
DESIGNATION
(Material No.08BAA9)
Non Aqueous Cleaner-General - -
(Material No.12ABB1)
Corrosion Preventive Compound-Water Displacing Hard Film -
(Material No.12ABC1)
Corrosion Preventive Compound_Water Displacing Soft Film -
(Material No.14SBA1)
Textile-Lint free Cotton -
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
251
AFT PASSENGER COMPARTMENT
252
AFT PASSENGER COMPARTMENT
261
AFT CABIN UTILITY AREA
262
AFT CABIN UTILITY AREA
 C. Referenced Information
REFERENCE
DESIGNATION
TASK 51-78-00-916-001-A
Application of Temporary Protection System (TPS)
TASK 53-00-00-000-801-A
Removal of the Floor Panels in the Cabin from FR12 to FR70
TASK 53-00-00-000-801-A-01
Removal of the Floor Panels in the Cabin from FR12 to FR70 (Alternative Removal Procedure - Dry Sealing Concept)
TASK 53-00-00-000-801-A-02
Removal of the Cabin Floor Panels from FR12 to FR70 (Alternative Removal Procedure with the Skyflex Option)
TASK 53-00-00-400-801-A
Installation of the Floor Panels in the Cabin from FR12 to FR70
TASK 53-00-00-400-801-A-01
Installation of the Floor Panels in the Cabin from FR12 to FR70 (Alternative Installation Procedure - Dry Sealing Concept)
TASK 53-00-00-400-801-A-02
Installation of the Cabin Floor Panels from FR12 to FR70 (Alternative Installation Procedure with the Skyflex Option)
SRM 511100
SRM 512200
3. Job Set-up
Subtask 53-41-00-010-135-A
A. Get Access
   (1) Remove the applicable floor panels (Ref. AMM TASK 53-00-00-000-801).
Subtask 53-41-00-110-086-A
B. Preparation of the Inspection Area
   (1) Make sure that the inspection area is sufficiently clean to do a satisfactory inspection of the area.
   (2) If not, clean the inspection area with Non Aqueous Cleaner-General - - (Material No.08BAA9) and the Textile-Lint free Cotton - (Material No.14SBA1) .
   (3) If there is a TPS layer and if it does not let you do a satisfactory inspection, remove the TPS layer (Ref. AMM TASK 51-78-00-916-001).
4. Procedure
Subtask 53-41-00-210-103-A
A. Inspection
   (1) Do a general visual inspection of the cabin floor structure for damage and discontinuities. This inspection does not include the areas below the galleys, the toilets and the door entrance area:
     (a) For A318, do this inspection between FR47/54 and FR70.
     (b) For A319, do this inspection between FR47/51 and FR70.
     (c) For A320 or A321, do this inspection between FR47 and FR70.
   (2) Make sure that there is no:
     (a) Corrosion:
If you find corrosion, refer to the Structural Repair Manual SRM 512200 for the corrosion types, inspection, removal and subsequent corrosion protection.
     (b) Other damage (scratches, cracks, gouges, dents, creases):
If you find this type of damage, refer to the Structural Repair Manual SRM 511100 for the damage types, classification and corrective action.
Subtask 53-41-00-916-078-A
B. Check and Application of the TPS Layer
   (1) If you removed the TPS at the ”Preparation of the Inspection Area”, apply a new layer of Corrosion Preventive Compound_Water Displacing Soft Film - (Material No.12ABC1) or Corrosion Preventive Compound-Water Displacing Hard Film - (Material No.12ABB1) (Ref. AMM TASK 51-78-00-916-001).
   (2) If you did not remove the TPS at the ”Preparation of the Inspection Area”, do a check of the condition and integrity of the TPS layer (Ref. AMM TASK 51-78-00-916-001).
   (3) If the TPS layer has local damage, remove the damaged TPS layer and apply a new layer of Corrosion Preventive Compound_Water Displacing Soft Film - (Material No.12ABC1) or Corrosion Preventive Compound-Water Displacing Hard Film - (Material No.12ABB1) (Ref. AMM TASK 51-78-00-916-001).
5. Close-up
Subtask 53-41-00-410-133-A
A. Close Access
   (1) Make sure that the work area is clean and clear of tools and other items.
   (2) Install the applicable floor panels (Ref. AMM TASK 53-00-00-400-801).
[Rev.10 from 2021] 2026.04.02 06:29:16 UTC