General Visual Inspection of Aft Cargo Door Lock Fittings and Surrounding Structure, External Portion (6 places)
TASK 53-41-00-210-038-A
General Visual Inspection of Aft Cargo Door Lock Fittings and Surrounding Structure, External Portion (6 places)
Refer to the MPD TASK: 534157-01
GENERAL VISUAL INSPECTION OF AFT CARGO DOOR LOCK FITTINGS AND SURROUNDING STRUCTURE, EXTERNAL PORTION (6 PLACES)
A. Fixtures, Tools, Test and Support Equipment
B. Consumable Materials
C. Work Zones and Access Panels
D. Referenced Information
3. Job Set-up
Subtask 53-41-00-010-113-A
Subtask 53-41-00-210-092-A
Subtask 53-41-00-410-111-A
[Rev.10 from 2021]
2026.04.02 06:29:16 UTC
General Visual Inspection of Aft Cargo Door Lock Fittings and Surrounding Structure, External Portion (6 places)
WARNING:
BE CAREFUL WHEN YOU USE CONSUMABLE MATERIALS. OBEY THE MATERIAL MANUFACTURER'S INSTRUCTIONS AND YOUR LOCAL REGULATIONS.
ZONE: 154
1. Reason for the JobRefer to the MPD TASK: 534157-01
GENERAL VISUAL INSPECTION OF AFT CARGO DOOR LOCK FITTINGS AND SURROUNDING STRUCTURE, EXTERNAL PORTION (6 PLACES)
NOTE: The effectivity of this task is ALL. To know, if this task is applicable for your aircraft, refer to the MPD task applicability and the weight variant data given in the SRM introduction.
2. Job Set-up InformationA. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 1 | ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE |
| REFERENCE | DESIGNATION |
|---|---|
| (Material No.05RDA1) | Adhesive Film Tape-Masking - - |
| (Material No.08BAA9) | Non Aqueous Cleaner-General - - |
| (Material No.14SBA1) | Textile-Lint free Cotton - |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 154 | U/FLOOR BAY OF AFT CARGO COMPARTMENT |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 51-78-00-916-001-A | Application of Temporary Protection System (TPS) |
| TASK 52-30-00-860-001-A | Open the FWD or Aft Cargo-Compartment Door with the Yellow Electric Pump |
| TASK 52-30-00-860-002-A | Close the FWD or Aft Cargo-Compartment Door with the Yellow Electric Pump |
| SRM 53461101 | (for corrective action) |
Subtask 53-41-00-010-113-A
A. Get Access
(1) Open the aft cargo-compartment door (Ref. AMM TASK 52-30-00-860-001).
(2) Put the ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE in position adjacent to the aft cargo-compartment door.
Subtask 53-41-00-110-156-A (1) Open the aft cargo-compartment door (Ref. AMM TASK 52-30-00-860-001).
(2) Put the ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE in position adjacent to the aft cargo-compartment door.
B. Preparation of the inspection area
(1) Make sure that the inspection area is sufficiently clean to do a satisfactory inspection of the area.
(3) Remove the TPS layer, if it does not let you do a satisfactory inspection (Ref. AMM TASK 51-78-00-916-001).
4. Procedure(1) Make sure that the inspection area is sufficiently clean to do a satisfactory inspection of the area.
WARNING:
BE CAREFUL WHEN YOU USE CONSUMABLE MATERIALS. OBEY THE MATERIAL MANUFACTURER'S INSTRUCTIONS AND YOUR LOCAL REGULATIONS.
(2) If not, clean the inspection area with Non Aqueous Cleaner-General - - (Material No.08BAA9) and a Textile-Lint free Cotton - (Material No.14SBA1) . (3) Remove the TPS layer, if it does not let you do a satisfactory inspection (Ref. AMM TASK 51-78-00-916-001).
Subtask 53-41-00-210-092-A
A. General Visual Inspection
(1) Do a general visual inspection of the lock fittings of the aft cargo door and the adjacent structure, external part (6 places).
(a) For A319, do this between FR56 and FR58A. Look for corrosion, cracks and other damages.
(b) For A320 and A321, do this between FR53 and FR55A. Look for corrosion, cracks and other damages.
Subtask 53-41-00-916-082-A (1) Do a general visual inspection of the lock fittings of the aft cargo door and the adjacent structure, external part (6 places).
(a) For A319, do this between FR56 and FR58A. Look for corrosion, cracks and other damages.
(b) For A320 and A321, do this between FR53 and FR55A. Look for corrosion, cracks and other damages.
NOTE: If necessary, refer to the ASRM SRM 53461101 for the correct repair procedure.
B. Application of Temporary Protection System
(2) If there is a TPS layer, do a check of the condition and integrity of the TPS layer (Ref. AMM TASK 51-78-00-916-001).
(4) If you used solvents, high-pressure water, steam and/or cleaning agents to clean the TPS layer:
(a) Apply a full new layer of TPS on the inspection area, as recommended in the MPD (Ref. AMM TASK 51-78-00-916-001).
(b) If there is no TPS layer, apply a new layer of TPS on the inspection area, as recommended in the MPD (Ref. AMM TASK 51-78-00-916-001).
(5) Remove the masking paper or the masking tape.
5. Close-upWARNING:
BE CAREFUL WHEN YOU USE CONSUMABLE MATERIALS. OBEY THE MATERIAL MANUFACTURER'S INSTRUCTIONS AND YOUR LOCAL REGULATIONS.
CAUTION:
DO NOT APPLY TEMPORARY PROTECTION ON THE OXYGEN SYSTEMS.
MAKE SURE THAT THE TEMPORARY PROTECTION DOES NOT GET:
(1) Apply masking paper or masking tape Adhesive Film Tape-Masking - - (Material No.05RDA1) on the equipment and fittings adjacent to the area. - ON COMPOSITE PARTS, CONTROL CABLES, PULLEYS,TEFLON BEARINGS.
- ON LUBRICATED SURFACES.
- IN DRAIN VALVES OR OTHER ORIFICES.
(2) If there is a TPS layer, do a check of the condition and integrity of the TPS layer (Ref. AMM TASK 51-78-00-916-001).
NOTE: Airbus recommends that you always apply a new layer of TPS. This is to make sure that the TPS layer continues to give satisfactory corrosion protection. Make sure that the TPS layer is in the correct condition after the check. If the TPS is in the correct condition, apply a new layer as a spray on the remaining layer.
(3) Replace the damaged TPS layer with a new layer of TPS on the inspection area, as recommended in the MPD (Ref. AMM TASK 51-78-00-916-001). (4) If you used solvents, high-pressure water, steam and/or cleaning agents to clean the TPS layer:
(a) Apply a full new layer of TPS on the inspection area, as recommended in the MPD (Ref. AMM TASK 51-78-00-916-001).
(b) If there is no TPS layer, apply a new layer of TPS on the inspection area, as recommended in the MPD (Ref. AMM TASK 51-78-00-916-001).
(5) Remove the masking paper or the masking tape.
Subtask 53-41-00-410-111-A
A. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Remove the access platform(s).
(3) Close the aft cargo-compartment door (Ref. AMM TASK 52-30-00-860-002).
(4) Remove the ground support and maintenance equipment, the special and standard tools and all other items.
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Remove the access platform(s).
(3) Close the aft cargo-compartment door (Ref. AMM TASK 52-30-00-860-002).
(4) Remove the ground support and maintenance equipment, the special and standard tools and all other items.
Lock Fittings of the Aft Cargo Door