W DOC AIRBUS | AMM A320F

Removal of the Fairlead


TASK 53-36-11-000-801-A
Removal of the Fairlead


ZONE: 140
ZONE: 190
1. Reason for the Job
Self Explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
1
ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE
No specific
AR
SAFETY CLIP - CIRCUIT BREAKER
No specific
1
WARNING NOTICE(S)
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
140
CENTER WING
190
BELLY FAIR, AIR CONDITIONING & HYD COMPT
 C. Referenced Information
REFERENCE
DESIGNATION
TASK 24-41-00-861-002-A
Energize the Aircraft Electrical Circuits from the External Power
TASK 24-41-00-861-002-A-01
Energize the Aircraft Electrical Circuits from the APU
TASK 24-41-00-861-002-A-02
Energize the Aircraft Electrical Circuits from Engine 1(2)
TASK 29-10-00-864-001-A
Depressurize the Green Hydraulic System
TASK 29-10-00-864-002-A
Depressurize the Yellow Hydraulic System
TASK 29-10-00-864-003-A
Depressurize the Blue Hydraulic System
TASK 32-12-00-010-001-A
Open the Main Gear Doors for Access
3. Job Set-up
Subtask 53-36-11-861-050-A
A. Aircraft Maintenance Configuration
   (1) Energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-861-002).
Subtask 53-36-11-010-050-A
B. Get Access
   (1) Open the MLG doors (Ref. AMM TASK 32-12-00-010-001).
   (2) Depressurize the Green, Blue, Yellow hydraulic systems (Ref. AMM TASK 29-10-00-864-001), (Ref. AMM TASK 29-10-00-864-002) and (Ref. AMM TASK 29-10-00-864-003).
   (3) Put the WARNING NOTICE(S) in position to tell persons not to operate the MLG.
   (4) Put the ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE in position.
Subtask 53-36-11-865-050-A
C. Open, safety and tag this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C ALL
49VUL/G/LGCIU/SYS1/NORM1GAC09
121VUHYDRAULIC/LGCIU/SYS22GAQ35
121VUHYDRAULIC/LGCIU/SYS1/GRND SPLY52GAQ34
4. Procedure
Subtask 53-36-11-020-050-A
A. Removal of the Fairlead
   (1) Remove the screws (5) and (6) and the washers (4) and (7).
   (2) Remove the plate (3).
   (3) Remove the fairlead (2) from the pressure plate (1).
   (4) Identify each half of the fairlead (2).
NOTE: This will help for the subsequent installation procedure.
   (5) If necessary, remove all the identification plates (8).
[Rev.10 from 2021] 2026.04.02 06:29:13 UTC