Removal of the Fairlead
TASK 53-36-11-000-801-A
Removal of the Fairlead
1. Reason for the Job
Self Explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 53-36-11-861-050-A
Subtask 53-36-11-020-050-A
[Rev.10 from 2021]
2026.04.02 06:29:13 UTC
Removal of the Fairlead
1. Reason for the Job
Self Explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 1 | ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE |
| No specific | AR | SAFETY CLIP - CIRCUIT BREAKER |
| No specific | 1 | WARNING NOTICE(S) |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 140 | CENTER WING |
| 190 | BELLY FAIR, AIR CONDITIONING & HYD COMPT |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 24-41-00-861-002-A | Energize the Aircraft Electrical Circuits from the External Power |
| TASK 24-41-00-861-002-A-01 | Energize the Aircraft Electrical Circuits from the APU |
| TASK 24-41-00-861-002-A-02 | Energize the Aircraft Electrical Circuits from Engine 1(2) |
| TASK 29-10-00-864-001-A | Depressurize the Green Hydraulic System |
| TASK 29-10-00-864-002-A | Depressurize the Yellow Hydraulic System |
| TASK 29-10-00-864-003-A | Depressurize the Blue Hydraulic System |
| TASK 32-12-00-010-001-A | Open the Main Gear Doors for Access |
Subtask 53-36-11-861-050-A
A. Aircraft Maintenance Configuration
(1) Energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-861-002).
Subtask 53-36-11-010-050-A (1) Energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-861-002).
B. Get Access
(1) Open the MLG doors (Ref. AMM TASK 32-12-00-010-001).
(2) Depressurize the Green, Blue, Yellow hydraulic systems (Ref. AMM TASK 29-10-00-864-001), (Ref. AMM TASK 29-10-00-864-002) and (Ref. AMM TASK 29-10-00-864-003).
(3) Put the WARNING NOTICE(S) in position to tell persons not to operate the MLG.
(4) Put the ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE in position.
Subtask 53-36-11-865-050-A (1) Open the MLG doors (Ref. AMM TASK 32-12-00-010-001).
(2) Depressurize the Green, Blue, Yellow hydraulic systems (Ref. AMM TASK 29-10-00-864-001), (Ref. AMM TASK 29-10-00-864-002) and (Ref. AMM TASK 29-10-00-864-003).
(3) Put the WARNING NOTICE(S) in position to tell persons not to operate the MLG.
(4) Put the ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE in position.
C. Open, safety and tag this(these) circuit breaker(s):
4. Procedure| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C ALL | |||
| 49VU | L/G/LGCIU/SYS1/NORM | 1GA | C09 |
| 121VU | HYDRAULIC/LGCIU/SYS2 | 2GA | Q35 |
| 121VU | HYDRAULIC/LGCIU/SYS1/GRND SPLY | 52GA | Q34 |
Subtask 53-36-11-020-050-A
A. Removal of the Fairlead
(1) Remove the screws (5) and (6) and the washers (4) and (7).
(2) Remove the plate (3).
(3) Remove the fairlead (2) from the pressure plate (1).
(4) Identify each half of the fairlead (2).
(1) Remove the screws (5) and (6) and the washers (4) and (7).
(2) Remove the plate (3).
(3) Remove the fairlead (2) from the pressure plate (1).
(4) Identify each half of the fairlead (2).
NOTE: This will help for the subsequent installation procedure.
(5) If necessary, remove all the identification plates (8).
Fairlead