W DOC AIRBUS | AMM A320F

Detailed Inspection of Hinge and Actuator Fittings for MLG Doors at Keelbeam


TASK 53-31-00-210-014-A
Detailed Inspection of Hinge and Actuator Fittings for MLG Doors at Keelbeam


WARNING: BE CAREFUL WHEN YOU USE CONSUMABLE MATERIALS. OBEY THE MATERIAL MANUFACTURER'S INSTRUCTIONS AND YOUR LOCAL REGULATIONS.
ZONE: 147
ZONE: 148
ZONE: 734
ZONE: 744
1. Reason for the Job
Refer to the MPD TASK: 533154-01
DETAILED INSPECTION OF HINGE AND ACTUATOR FITTINGS FOR MLG DOORS AT KEELBEAM
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
1
ACCESS PLATFORM 2M (6 FT)
No specific
1
WARNING NOTICE(S)
460005835
2
SLEEVE - GROUND LOCK
 B. Consumable Materials
REFERENCE
DESIGNATION
(Material No.05RDA1)
Adhesive Film Tape-Masking - -
(Material No.08BAA9)
Non Aqueous Cleaner-General - -
(Material No.14SBA1)
Textile-Lint free Cotton -
 C. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
147
MAIN GEAR WELL AND HYDRAULIC COMPARTMENT
148
MAIN GEAR WELL AND HYDRAULIC COMPARTMENT
734
MAIN DOOR
744
MAIN DOOR
 D. Referenced Information
REFERENCE
DESIGNATION
TASK 29-10-00-864-001-A
Depressurize the Green Hydraulic System
TASK 29-10-00-864-002-A
Depressurize the Yellow Hydraulic System
TASK 29-10-00-864-003-A
Depressurize the Blue Hydraulic System
TASK 32-00-00-081-002-A
Removal of the Safety Devices from the Landing Gear Doors
TASK 32-00-00-481-002-A
Installation of the Safety Devices on the Landing Gear Doors
TASK 32-12-00-010-001-A
Open the Main Gear Doors for Access
TASK 32-12-00-410-001-A
Close the Main Gear Doors after Access
TASK 32-12-11-400-001-A
Installation of the Door Assembly - Main
TASK 32-31-35-400-001-A
Installation of the MLG Door Actuating-Cylinder
TASK 51-78-00-916-001-A
Application of Temporary Protection System (TPS)
SRM 511100
SRM 512200
3. Job Set-up
Subtask 53-31-00-010-067-A
A. Get Access
   (1) Make sure that the MLG doors are open (Ref. AMM TASK 32-12-00-010-001).
   (2) For each MLG door, install the 460005835 SLEEVE - GROUND LOCK on the MLG door actuator-cylinder (Ref. AMM TASK 32-00-00-481-002).
   (3) Make sure that the Green, Blue and Yellow hydraulic systems are depressurized (Ref. AMM TASK 29-10-00-864-001), (Ref. AMM TASK 29-10-00-864-002) and (Ref. AMM TASK 29-10-00-864-003).
   (4) Put the WARNING NOTICE(S) in position to tell persons not to operate the landing gears.
   (5) Put the ACCESS PLATFORM 2M (6 FT) in position.
Subtask 53-31-00-110-117-A
B. Preparation of the inspection area
   (1) Make sure that the inspection area is sufficiently clean to do a satisfactory inspection of the area.
   (2) If not, clean the inspection area with Non Aqueous Cleaner-General - - (Material No.08BAA9) and a Textile-Lint free Cotton - (Material No.14SBA1) .
   (3) Remove the TPS layer, if it does not let you do a satisfactory inspection (Ref. AMM TASK 51-78-00-916-001).
4. Procedure
Subtask 53-31-00-210-063-A
A. Inspection
   (1) Do a detailed inspection of the forward and aft keel-beam hinge-fittings of the left and right MLG doors. For each forward and aft keel-beam hinge-fitting, do a check for damage or discontinuities of:
  • The hinge fitting
  • The bearing
  • The spacers
  • Around the head of the bolt.
   (2) Make sure that there is no:
     (a) Corrosion damage:
If you find corrosion, refer to the Structural Repair Manual ( SRM 512200) for the corrosion types, inspection, removal and subsequent corrosion protection.
     (b) Other damage (scratches, cracks, gouges, dents, creases):
If you find this type of damage, refer to the Structural Repair Manual ( SRM 511100) for the damage types, classification and corrective action.
   (3) Make sure that for each MLG door (Ref. AMM TASK 32-12-11-400-001):
     (a) The forward and aft keel-beam hinge-fittings are correctly installed and adjusted.
     (b) The spacer and a maximum of two shim washers are installed.
   (4) Do a detailed inspection of the keel-beam actuator fittings of the left and right MLG doors. For each keel-beam actuator fitting, do a check for damage or discontinuities of:
  • The actuator fitting
  • The bearing.
   (5) Make sure that there is no:
     (a) Corrosion damage:
If you find corrosion, refer to the Structural Repair Manual ( SRM 512200) for the corrosion types, inspection, removal and subsequent corrosion protection.
     (b) Other damage (scratches, cracks, gouges, dents, creases):
If you find this type of damage, refer to the Structural Repair Manual ( SRM 511100) for the damage types, classification and corrective action.
   (6) Make sure that for each MLG door, the MLG door actuator and the spacer are correctly installed and adjusted (Ref. AMM TASK 32-31-35-400-001).
Subtask 53-31-00-916-061-A
B. Application of Temporary Protection System
WARNING: BE CAREFUL WHEN YOU USE CONSUMABLE MATERIALS. OBEY THE MATERIAL MANUFACTURER'S INSTRUCTIONS AND YOUR LOCAL REGULATIONS.
CAUTION: DO NOT APPLY TEMPORARY PROTECTION ON THE OXYGEN SYSTEMS. MAKE SURE THAT THE TEMPORARY PROTECTION DOES NOT GET:
  • ON COMPOSITE PARTS, CONTROL CABLES, PULLEYS,TEFLON BEARINGS.
  • ON LUBRICATED SURFACES.
  • IN DRAIN VALVES OR OTHER ORIFICES.
TEMPORARY PROTECTION ON OR IN THESE PARTS CAN CAUSE DAMAGE.
   (1) Apply masking paper or masking tape Adhesive Film Tape-Masking - - (Material No.05RDA1) on the equipment and fittings adjacent to the area.
   (2) If there is a TPS layer, do a check of the condition and integrity of the TPS layer (Ref. AMM TASK 51-78-00-916-001).
NOTE: Airbus recommends that you always apply a new layer of TPS. This is to make sure that the TPS layer continues to give satisfactory corrosion protection. Make sure that the TPS layer is in the correct condition after the check. If the TPS is in the correct condition, apply a new layer as a spray on the remaining layer.
   (3) Replace the damaged TPS layer with a new layer of TPS on the inspection area, as recommended in the MPD (Ref. AMM TASK 51-78-00-916-001).
   (4) If you used solvents, high-pressure water, steam and/or cleaning agents to clean the TPS layer:
     (a) Apply a full new layer of TPS on the inspection area, as recommended in the MPD (Ref. AMM TASK 51-78-00-916-001).
     (b) If there is no TPS layer, apply a new layer of TPS on the inspection area, as recommended in the MPD (Ref. AMM TASK 51-78-00-916-001).
   (5) Remove the masking paper or the masking tape.
5. Close-up
Subtask 53-31-00-410-063-A
A. Close Access
   (1) Make sure that the work area is clean and clear of tools and other items.
   (2) For each MLG door, remove the 460005835 SLEEVE - GROUND LOCK from the MLG door actuator-cylinder (Ref. AMM TASK 32-00-00-081-002).
   (3) Close the MLG doors (Ref. AMM TASK 32-12-00-410-001).
   (4) Remove the access platform(s).
   (5) Remove the WARNING NOTICE(S).
[Rev.10 from 2021] 2026.04.02 06:29:05 UTC