Detailed Inspection of Lower Surface of Pressure Deck Membranes, between FR 42 and FR 46, Including Connections to Longitudinal Beams, Side Boxes, ...
TASK 53-31-00-210-006-A
Detailed Inspection of Lower Surface of Pressure Deck Membranes, between FR 42 and FR 46, Including Connections to Longitudinal Beams, Side Boxes, ...
Refer to the MPD TASK: 533111-01
DETAILED INSPECTION OF LOWER SURFACE OF PRESSURE DECK MEMBRANES, BETWEEN FR 42 AND FR 46, INCLUDING CONNECTIONS TO LONGITUDINAL BEAMS, SIDE BOXES, SUPPORT RIBS, REAR SPAR OF CENTER WING BOX AND PRESSURE BULKHEAD, LH/RH
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Consumable Materials
C. Work Zones and Access Panels
D. Referenced Information
3. Job Set-up
Subtask 53-31-00-010-055-A
Subtask 53-31-00-210-055-A
Subtask 53-31-00-865-057-A
[Rev.10 from 2021]
2026.04.02 06:29:04 UTC
Detailed Inspection of Lower Surface of Pressure Deck Membranes, between FR 42 and FR 46, Including Connections to Longitudinal Beams, Side Boxes, ...
WARNING:
BE CAREFUL WHEN YOU USE CONSUMABLE MATERIALS. OBEY THE MATERIAL MANUFACTURER'S INSTRUCTIONS AND YOUR LOCAL REGULATIONS.
1. Reason for the JobRefer to the MPD TASK: 533111-01
DETAILED INSPECTION OF LOWER SURFACE OF PRESSURE DECK MEMBRANES, BETWEEN FR 42 AND FR 46, INCLUDING CONNECTIONS TO LONGITUDINAL BEAMS, SIDE BOXES, SUPPORT RIBS, REAR SPAR OF CENTER WING BOX AND PRESSURE BULKHEAD, LH/RH
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 1 | ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE |
| No specific | AR | SAFETY CLIP - CIRCUIT BREAKER |
| No specific | 1 | WARNING NOTICE(S) |
| REFERENCE | DESIGNATION |
|---|---|
| (Material No.08BBB1) | Non Aqueous Cleaner-- Petroleum Based - |
| (Material No.14SBA1) | Textile-Lint free Cotton - |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 147 | MAIN GEAR WELL AND HYDRAULIC COMPARTMENT |
| 148 | MAIN GEAR WELL AND HYDRAULIC COMPARTMENT |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 24-41-00-862-002-A | De-energize the Aircraft Electrical Circuits Supplied from the External Power |
| TASK 24-41-00-862-002-A-01 | De-energize the Aircraft Electrical Circuits Supplied from the APU |
| TASK 24-41-00-862-002-A-02 | De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2) |
| TASK 29-10-00-864-001-A | Depressurize the Green Hydraulic System |
| TASK 29-10-00-864-002-A | Depressurize the Yellow Hydraulic System |
| TASK 29-10-00-864-003-A | Depressurize the Blue Hydraulic System |
| TASK 32-00-00-860-001-A | Flight Configuration Precautions with Electrical Power |
| TASK 32-00-00-860-001-A-01 | Flight Configuration Precautions without Electrical Power |
| TASK 32-12-00-010-001-A | Open the Main Gear Doors for Access |
| TASK 32-12-00-410-001-A | Close the Main Gear Doors after Access |
| SRM 53311400 | (for corrective action) |
| SRM 53311600 | (for corrective action) |
Subtask 53-31-00-010-055-A
A. Get Access
(1) Open the MLG doors (Ref. AMM TASK 32-12-00-010-001).
(2) Depressurize the Green, Blue and Yellow hydraulic systems (Ref. AMM TASK 29-10-00-864-001), (Ref. AMM TASK 29-10-00-864-002), (Ref. AMM TASK 29-10-00-864-003).
(3) Put the WARNING NOTICE(S) in position to tell persons not to operate the landing gear.
(4) Put the ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE in position.
Subtask 53-31-00-869-054-A (1) Open the MLG doors (Ref. AMM TASK 32-12-00-010-001).
(2) Depressurize the Green, Blue and Yellow hydraulic systems (Ref. AMM TASK 29-10-00-864-001), (Ref. AMM TASK 29-10-00-864-002), (Ref. AMM TASK 29-10-00-864-003).
(3) Put the WARNING NOTICE(S) in position to tell persons not to operate the landing gear.
(4) Put the ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE in position.
B. Flight Configuration Precautions
(1) If the electrical power is not necessary for other maintenance tasks, de-energize the aircraft electrical circuits (Ref. AMM TASK 24-41-00-862-002). Then, it is not necessary to operate the LGCIU circuit breakers.
(2) If the electrical power is necessary, do the precautions for flight configuration (Ref. AMM TASK 32-00-00-860-001) before you open the LGCIU circuit breakers.
Subtask 53-31-00-865-056-A (1) If the electrical power is not necessary for other maintenance tasks, de-energize the aircraft electrical circuits (Ref. AMM TASK 24-41-00-862-002). Then, it is not necessary to operate the LGCIU circuit breakers.
(2) If the electrical power is necessary, do the precautions for flight configuration (Ref. AMM TASK 32-00-00-860-001) before you open the LGCIU circuit breakers.
C. Open, safety and tag this(these) circuit breaker(s):
Subtask 53-31-00-110-106-A | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C ALL | |||
| 49VU | L/G/LGCIU/SYS1/NORM | 1GA | C09 |
| 121VU | HYDRAULIC/LGCIU/SYS2 | 2GA | Q35 |
| 121VU | HYDRAULIC/LGCIU/SYS1/GRND SPLY | 52GA | Q34 |
D. Preparation of the Inspection Area
(1) Carefully clean the lower surface of the pressure deck with Non Aqueous Cleaner-- Petroleum Based - (Material No.08BBB1) and a clean lint-free cloth Textile-Lint free Cotton - (Material No.14SBA1) .
4. Procedure(1) Carefully clean the lower surface of the pressure deck with Non Aqueous Cleaner-- Petroleum Based - (Material No.08BBB1) and a clean lint-free cloth Textile-Lint free Cotton - (Material No.14SBA1) .
Subtask 53-31-00-210-055-A
A. Inspection
(1) Examine the lower surface of the pressure deck membranes between FR42 thru FR46 with the connections to the longitudinal beams, side boxes, support ribs, rear spar of the wing box and the pressure bulkhead, LH/RH for:
5. Close-up(1) Examine the lower surface of the pressure deck membranes between FR42 thru FR46 with the connections to the longitudinal beams, side boxes, support ribs, rear spar of the wing box and the pressure bulkhead, LH/RH for:
- cracks,
- corrosion,
NOTE: If necessary, refer to the ASRM SRM 53311400 and SRM 53311600 for the correct repair procedures.
Subtask 53-31-00-865-057-A
A. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
Subtask 53-31-00-410-055-A | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C ALL | |||
| 49VU | L/G/LGCIU/SYS1/NORM | 1GA | C09 |
| 121VU | HYDRAULIC/LGCIU/SYS2 | 2GA | Q35 |
| 121VU | HYDRAULIC/LGCIU/SYS1/GRND SPLY | 52GA | Q34 |
B. Close Access
(1) Close the MLG doors (Ref. AMM TASK 32-12-00-410-001).
(2) Remove the WARNING NOTICE(S).
(3) Remove the access platform(s).
(4) Remove the ground support and maintenance equipment, the special and standard tools and all other items.
(1) Close the MLG doors (Ref. AMM TASK 32-12-00-410-001).
(2) Remove the WARNING NOTICE(S).
(3) Remove the access platform(s).
(4) Remove the ground support and maintenance equipment, the special and standard tools and all other items.
Lower Surface of the Pressure Deck Membranes