W DOC AIRBUS | AMM A320F

Detailed Inspection of Pressure Bulkhead at FR46, FWD Face


TASK 53-31-00-210-002-A
Detailed Inspection of Pressure Bulkhead at FR46, FWD Face


WARNING: BE CAREFUL WHEN YOU USE CONSUMABLE MATERIALS. OBEY THE MATERIAL MANUFACTURER'S INSTRUCTIONS AND YOUR LOCAL REGULATIONS.
ZONE: 147
ZONE: 148
1. Reason for the Job
Refer to the MPD TASK: 533101-01
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
1
ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE
No specific
AR
SAFETY CLIP - CIRCUIT BREAKER
No specific
1
WARNING NOTICE(S)
 B. Consumable Materials
REFERENCE
DESIGNATION
(Material No.08BBB1)
Non Aqueous Cleaner-- Petroleum Based -
(Material No.14SBA1)
Textile-Lint free Cotton -
 C. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
147
MAIN GEAR WELL AND HYDRAULIC COMPARTMENT
148
MAIN GEAR WELL AND HYDRAULIC COMPARTMENT
 D. Referenced Information
REFERENCE
DESIGNATION
TASK 29-10-00-864-001-A
Depressurize the Green Hydraulic System
TASK 29-10-00-864-002-A
Depressurize the Yellow Hydraulic System
TASK 29-10-00-864-003-A
Depressurize the Blue Hydraulic System
TASK 32-12-00-010-001-A
Open the Main Gear Doors for Access
TASK 32-12-00-410-001-A
Close the Main Gear Doors after Access
SRM 53311600
(for corrective action)
3. Job Set-up
Subtask 53-31-00-010-051-A
A. Get Access
   (1) Open the MLG doors (Ref. AMM TASK 32-12-00-010-001).
   (2) Depressurize the Green, Blue and Yellow hydraulic systems (Ref. AMM TASK 29-10-00-864-001), (Ref. AMM TASK 29-10-00-864-002), (Ref. AMM TASK 29-10-00-864-003).
   (3) Put the WARNING NOTICE(S) in position to tell persons not to operate the landing gear.
   (4) Put the ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE in position.
Subtask 53-31-00-110-103-A
B. Preparation of the Inspection Area
   (1) Carefully clean the forward face of the pressure bulkhead at FR46 with Non Aqueous Cleaner-- Petroleum Based - (Material No.08BBB1) and a clean lint-free cloth Textile-Lint free Cotton - (Material No.14SBA1) .
Subtask 53-31-00-865-050-A
C. Open, safety and tag this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C ALL
49VUL/G/LGCIU/SYS1/NORM1GAC09
121VUHYDRAULIC/LGCIU/SYS22GAQ35
121VUHYDRAULIC/LGCIU/SYS1/GRND SPLY52GAQ34
4. Procedure
Subtask 53-31-00-210-051-A
A. Inspection
   (1) Examine the forward face of the pressure bulkhead at FR46 for cracks.
NOTE: If necessary, refer to the ASRM SRM 53311600 for the correct repair procedure.
5. Close-up
Subtask 53-31-00-865-051-A
A. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C ALL
49VUL/G/LGCIU/SYS1/NORM1GAC09
121VUHYDRAULIC/LGCIU/SYS22GAQ35
121VUHYDRAULIC/LGCIU/SYS1/GRND SPLY52GAQ34
Subtask 53-31-00-410-051-A
B. Close Access
   (1) Close the MLG doors (Ref. AMM TASK 32-12-00-410-001).
   (2) Remove the WARNING NOTICE(S).
   (3) Remove the access platform(s).
   (4) Remove the ground support and maintenance equipment, the special and standard tools and all other items.
[Rev.8 from Aug 2017] 2026.04.02 06:29:08 UTC