W DOC AIRBUS | AMM A320F

Special Detailed Inspection of Frame Splicing at STR35 from FR35 to FR35.7 and Junction between Frame and Vertical Struts at STR32, LH/RH


TASK 53-21-00-280-803-A
Special Detailed Inspection of Frame Splicing at STR35 from FR35 to FR35.7 and Junction between Frame and Vertical Struts at STR32, LH/RH


WARNING: BE CAREFUL WHEN YOU USE CONSUMABLE MATERIALS. OBEY THE MATERIAL MANUFACTURER'S INSTRUCTIONS AND YOUR LOCAL REGULATIONS.
ZONE: 131
ZONE: 132
1. Reason for the Job
Refer to the MPD TASK: 532208-01
SPECIAL DETAILED INSPECTION (ROTO) OF FRAME SPLICING AT STR35 FROM FR35 TO FR35.7 AND JUNCTION BETWEEN FRAME AND VERTICAL STRUTS AT STR32, LH/RH
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
1
ACCESS PLATFORM 2M (6 FT)
 B. Consumable Materials
REFERENCE
DESIGNATION
(Material No.08BAA9)
Non Aqueous Cleaner-General - -
(Material No.14SBA1)
Textile-Lint free Cotton -
 C. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
131
FORWARD CARGO COMPARTMENT
132
FORWARD CARGO COMPARTMENT
825
 D. Referenced Information
REFERENCE
DESIGNATION
TASK 25-54-12-000-001-A
Removal of the Forward Cargo-Compartment Partition
TASK 25-54-12-000-003-A
Removal of the Sidewall Panels in the Forward Cargo Compartment
TASK 25-54-12-400-001-A
Installation of the Forward Cargo-Compartment Partition
TASK 25-54-12-400-003-A
Installation of the Sidewall Panels in the Forward Cargo Compartment
TASK 25-80-00-000-001-A
Removal of the Insulation Blankets
TASK 25-80-00-400-001-A
Installation of the Insulation Blankets
TASK 52-30-00-860-001-A
Open the FWD or Aft Cargo-Compartment Door with the Yellow Electric Pump
TASK 52-30-00-860-002-A
Close the FWD or Aft Cargo-Compartment Door with the Yellow Electric Pump
TASK 53-22-14-000-001-A
Removal of the Forward Cargo-Compartment Floor-Panels
TASK 53-22-14-400-001-A
Installation of the Forward Cargo-Compartment Floor-Panels
TASK 53-22-14-400-001-A-01
Installation of the Forward Cargo-Compartment Floor-Panels (Alternative Installation Procedure with the Skyflex Option)
SRM 511100
SRM 512200
SRM 514200
NTM 532208
TASK 06-41-53-00
FUSELAGE-DESCRIPTION AND OPERATION
3. Job Set-up
Subtask 53-21-00-010-159-A ** ON A/C NOT FOR ALL
A. Get Access
   (1) Put the ACCESS PLATFORM 2M (6 FT) in position at zone 131(132).
   (2) Open forward cargo-compartment door 825 (Ref. AMM TASK 52-30-00-860-001).
   (3) Remove the applicable sidewall panels between FR35 and FR35.5 (Ref. AMM D/O 06-41-53-00) and (Ref. AMM TASK 25-54-12-000-003).
   (4) Remove the applicable cargo floor panels between FR35 and FR35.5 (Ref. AMM D/O 06-41-53-00) and (Ref. AMM TASK 53-22-14-000-001).
   (5) Remove the applicable partition panels at FR35.5 (Ref. AMM TASK 25-54-12-000-001).
   (6) Remove the applicable insulation blankets between FR35 and FR35.5 (Ref. AMM TASK 25-80-00-000-001).
Subtask 53-21-00-110-177-A ** ON A/C NOT FOR ALL
B. Preparation of the Inspection Area
   (1) Make sure that the inspection area is sufficiently clean to do a satisfactory inspection of the area.
   (2) If not, clean the inspection area with Non Aqueous Cleaner-General - - (Material No.08BAA9) and the Textile-Lint free Cotton - (Material No.14SBA1) .
   (3) Remove the fasteners to examine the holes SRM 514200.
4. Procedure
Subtask 53-21-00-250-082-A ** ON A/C NOT FOR ALL
A. Inspection
   (1) Do a special detailed inspection of:
     (a) The frame splicing, at stringer 35, from FR35 to FR35.7
     (b) The junction, at stringer 32 between the frame and the vertical struts.
Do this inspection on the left and right sides of the frame splicing and the junction for damage and discontinuities NTM 532208.
   (2) Make a report of the damage after the NTM inspection:
     (a) Corrosion:
If you find corrosion, refer to the Structural Repair Manual SRM 512200 for the corrosion types, inspection, removal and subsequent corrosion protection.
     (b) Other damage (scratches, cracks, gouges, dents, creases):
If you find this type of damage, refer to the Structural Repair Manual SRM 511100 for damage types, classification and corrective action.
Subtask 53-21-00-420-087-A ** ON A/C NOT FOR ALL
B. Installation of the Fasteners
   (1) Refer to the installation drawing in the SRM identification section for the new fastener references.
   (2) Install the fasteners of the examined holes SRM 514200.
5. Close-up
Subtask 53-21-00-410-152-A ** ON A/C NOT FOR ALL
A. Close Access
   (1) Make sure that the work area is clean and clear of tools and other items.
   (2) Install the removed insulation blankets between FR35 and FR35.5 (Ref. AMM TASK 25-80-00-400-001).
   (3) Install the removed partition panels at FR35.5 (Ref. AMM TASK 25-54-12-400-001).
   (4) Install the removed cargo floor panels between FR35 and FR35.5 (Ref. AMM D/O 06-41-53-00) and (Ref. AMM TASK 53-22-14-400-001).
   (5) Install the removed sidewall panels between FR35 and FR35.5 (Ref. AMM D/O 06-41-53-00) and (Ref. AMM TASK 25-54-12-400-003).
   (6) Close forward cargo-compartment door 825 (Ref. AMM TASK 52-30-00-860-002).
   (7) Remove the access platform(s).
[Rev.10 from 2021] 2026.04.02 06:28:56 UTC