Detailed Inspection of Fuselage Skin around Forward Emergency Exit Skin Cut Out between FR 35 and FR 35.3 and from Stringer 8 to Stringer 23, External ...
TASK 53-21-00-220-809-A
Detailed Inspection of Fuselage Skin around Forward Emergency Exit Skin Cut Out between FR 35 and FR 35.3 and from Stringer 8 to Stringer 23, External ...
Refer to the MPD TASK: 532152-02
DETAILED INSPECTION OF FUSELAGE SKIN AROUND FORWARD EMERGENCY EXIT SKIN CUT OUT BETWEEN FR 35 AND FR 35.3
AND FROM STRINGER 8 TO STRINGER 23, EXTERNAL SURFACE, LH/RH.
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Consumable Materials
C. Work Zones and Access Panels
D. Referenced Information
3. Job Set-up
Subtask 53-21-00-010-121-A ** ON A/C NOT FOR ALL
Subtask 53-21-00-220-101-A ** ON A/C NOT FOR ALL
Subtask 53-21-00-410-115-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.02 06:28:58 UTC
Detailed Inspection of Fuselage Skin around Forward Emergency Exit Skin Cut Out between FR 35 and FR 35.3 and from Stringer 8 to Stringer 23, External ...
WARNING:
BE CAREFUL WHEN YOU USE CONSUMABLE MATERIALS. OBEY THE MATERIAL MANUFACTURER'S INSTRUCTIONS AND YOUR LOCAL REGULATIONS.
ZONE: 230
1. Reason for the JobRefer to the MPD TASK: 532152-02
DETAILED INSPECTION OF FUSELAGE SKIN AROUND FORWARD EMERGENCY EXIT SKIN CUT OUT BETWEEN FR 35 AND FR 35.3
AND FROM STRINGER 8 TO STRINGER 23, EXTERNAL SURFACE, LH/RH.
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | ACCESS PLATFORM 6M (20 FT) - ADJUSTABLE |
| REFERENCE | DESIGNATION |
|---|---|
| (Material No.08BAA9) | Non Aqueous Cleaner-General - - |
| (Material No.14SBA1) | Textile-Lint free Cotton - |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 230 | FWD PASSENGER COMPARTMENT |
| REFERENCE | DESIGNATION |
|---|---|
| SRM 511100 | (for corrective action) |
| SRM 512200 | (for corrective action) |
Subtask 53-21-00-010-121-A ** ON A/C NOT FOR ALL
A. Get Access
(1) Put an ACCESS PLATFORM 6M (20 FT) - ADJUSTABLE in position in zone 230.
Subtask 53-21-00-110-142-A ** ON A/C NOT FOR ALL (1) Put an ACCESS PLATFORM 6M (20 FT) - ADJUSTABLE in position in zone 230.
B. Preparation of the Inspection Area
(1) Make sure that the inspection area is sufficiently clean to do a satisfactory inspection of the area.
(2) If it is not sufficiently clean, clean the inspection area with Non Aqueous Cleaner-General - - (Material No.08BAA9) and Textile-Lint free Cotton - (Material No.14SBA1) .
4. Procedure(1) Make sure that the inspection area is sufficiently clean to do a satisfactory inspection of the area.
(2) If it is not sufficiently clean, clean the inspection area with Non Aqueous Cleaner-General - - (Material No.08BAA9) and Textile-Lint free Cotton - (Material No.14SBA1) .
Subtask 53-21-00-220-101-A ** ON A/C NOT FOR ALL
A. Inspection
(1) Do a detailed inspection of the external surface of the fuselage skin around the skin cutout of the forward emergency exit between FR35 and FR35.3. This inspection includes the area from stringer 8 to stringer 23 (left and right sides).
(2) Make sure that there is no:
(a) Corrosion damage:
5. Close-up(1) Do a detailed inspection of the external surface of the fuselage skin around the skin cutout of the forward emergency exit between FR35 and FR35.3. This inspection includes the area from stringer 8 to stringer 23 (left and right sides).
(2) Make sure that there is no:
(a) Corrosion damage:
- If you find corrosion damage, refer to Structural Repair Manual SRM 512200 for types of corrosion, inspection, removal and corrosion protection.
- If you find this type of damage, refer to Structural Repair Manual SRM 511100 for damage classification and related corrective action.
Subtask 53-21-00-410-115-A ** ON A/C NOT FOR ALL
A. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Remove the access platform(s).
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Remove the access platform(s).
Skin Cutout of the Forward Emergency Exit between FR35 and FR35.3