Detailed Inspection of Fuselage External Surface around Water Drain Panel Cutout and Radius Inside Water Drain Box, between FR 28 and FR 29...
TASK 53-21-00-220-806-A
Detailed Inspection of Fuselage External Surface around Water Drain Panel Cutout and Radius Inside Water Drain Box, between FR 28 and FR 29...
Refer to the MPD TASK: 532190-02
DETAILED INSPECTION OF FUSELAGE EXTERNAL SURFACE AROUND WATER DRAIN PANEL CUTOUT AND RADIUS INSIDE WATER DRAIN BOX, BETWEEN FR 28 AND FR 29 AT STRINGER 43 LH.
A. Fixtures, Tools, Test and Support Equipment
B. Consumable Materials
C. Work Zones and Access Panels
D. Referenced Information
3. Job Set-up
Subtask 53-21-00-941-100-A ** ON A/C NOT FOR ALL
Subtask 53-21-00-220-095-A ** ON A/C NOT FOR ALL
Subtask 53-21-00-942-105-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.02 06:28:58 UTC
Detailed Inspection of Fuselage External Surface around Water Drain Panel Cutout and Radius Inside Water Drain Box, between FR 28 and FR 29...
WARNING:
BE CAREFUL WHEN YOU USE CONSUMABLE MATERIALS. OBEY THE MATERIAL MANUFACTURER'S INSTRUCTIONS AND YOUR LOCAL REGULATIONS.
1. Reason for the JobRefer to the MPD TASK: 532190-02
DETAILED INSPECTION OF FUSELAGE EXTERNAL SURFACE AROUND WATER DRAIN PANEL CUTOUT AND RADIUS INSIDE WATER DRAIN BOX, BETWEEN FR 28 AND FR 29 AT STRINGER 43 LH.
NOTE: The effectivity of this task is "ALL". To know if this task is applicable to your aircraft, refer to the MPD task applicability.
The information on weight variant groups is given in the MPD and SRM introductions.
2. Job Set-up InformationThe information on weight variant groups is given in the MPD and SRM introductions.
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE |
| REFERENCE | DESIGNATION |
|---|---|
| (Material No.08BAA9) | Non Aqueous Cleaner-General - - |
| (Material No.14SBA1) | Textile-Lint free Cotton - |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 100 | LOWER HALF FUSELAGE INCLUDING RADOME |
| 130 | FWD CARGO COMPT AFT BULKHEAD OF AVNCS COMPT TO FWD PRESSURE BULKHEAD OF WING CENTER BOX |
| 133AL |
| REFERENCE | DESIGNATION |
|---|---|
| SRM 511100 | |
| SRM 512200 | |
| SRM 512300 | |
Subtask 53-21-00-941-100-A ** ON A/C NOT FOR ALL
A. Get Access
(1) Put the ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE in position at zone 130.
(2) Open potable water service-door 133AL.
Subtask 53-21-00-110-130-A ** ON A/C NOT FOR ALL (1) Put the ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE in position at zone 130.
(2) Open potable water service-door 133AL.
B. Preparation of the Inspection Area
(1) Make sure that the inspection area is sufficiently clean to do a satisfactory inspection of the area.
(2) If not, clean the inspection area with Non Aqueous Cleaner-General - - (Material No.08BAA9) and the Textile-Lint free Cotton - (Material No.14SBA1) .
4. Procedure(1) Make sure that the inspection area is sufficiently clean to do a satisfactory inspection of the area.
(2) If not, clean the inspection area with Non Aqueous Cleaner-General - - (Material No.08BAA9) and the Textile-Lint free Cotton - (Material No.14SBA1) .
Subtask 53-21-00-220-095-A ** ON A/C NOT FOR ALL
A. Inspection
(1) Do a detailed inspection of the area between FR28 and FR29 at STGR43, on the left side. Do a check for damage or discontinuities of:
(a) Corrosion damage:
If you find corrosion, refer to the Structural Repair Manual ( SRM 512200) for the corrosion types, inspection, removal and subsequent corrosion protection.
(b) Other damage (scratches, cracks, gouges, dents, creases):
If you find this type of damage, refer to the Structural Repair Manual ( SRM 511100) for the damage types, classification and corrective action.
(c) Paint layer damage:
If you find this type of damage, refer to the Structural Repair Manual ( SRM 512300) for general data for paint layers.
5. Close-up(1) Do a detailed inspection of the area between FR28 and FR29 at STGR43, on the left side. Do a check for damage or discontinuities of:
- The fuselage external surface around the water-drain panel cutout
- The radius in the water drain box.
(a) Corrosion damage:
If you find corrosion, refer to the Structural Repair Manual ( SRM 512200) for the corrosion types, inspection, removal and subsequent corrosion protection.
(b) Other damage (scratches, cracks, gouges, dents, creases):
If you find this type of damage, refer to the Structural Repair Manual ( SRM 511100) for the damage types, classification and corrective action.
(c) Paint layer damage:
If you find this type of damage, refer to the Structural Repair Manual ( SRM 512300) for general data for paint layers.
Subtask 53-21-00-942-105-A ** ON A/C NOT FOR ALL
A. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Close potable water service-door 133AL.
(3) Remove the access platform(s).
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Close potable water service-door 133AL.
(3) Remove the access platform(s).
Fuselage External Surface around the Water-Drain Panel Cutout and the Radius in the Water Drain Box, between FR28 and FR29 at STGR43, on the Left Side