General Visual Inspection of Cabin Floor Structure, Excluding Areas below Galleys and Toilets (if Installed) and Emergency Exit Entrance Area, between...
TASK 53-21-00-210-001-B
General Visual Inspection of Cabin Floor Structure, Excluding Areas below Galleys and Toilets (if Installed) and Emergency Exit Entrance Area, between...
Refer to the MPD TASK: 532102-01
GENERAL VISUAL INSPECTION OF CABIN FLOOR STRUCTURE, EXCLUDING AREAS BELOW GALLEYS AND TOILETS (IF INSTALLED), BETWEEN FR 24 AND FR 35
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Consumable Materials
C. Work Zones and Access Panels
D. Referenced Information
3. Job Set-up
Subtask 53-21-00-010-085-A ** ON A/C NOT FOR ALL Subtask 53-21-00-110-089-A ** ON A/C NOT FOR ALL
Subtask 53-21-00-210-074-A ** ON A/C NOT FOR ALL
Subtask 53-21-00-410-083-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.02 06:28:57 UTC
General Visual Inspection of Cabin Floor Structure, Excluding Areas below Galleys and Toilets (if Installed) and Emergency Exit Entrance Area, between...
WARNING:
BE CAREFUL WHEN YOU USE CONSUMABLE MATERIALS. OBEY THE MATERIAL MANUFACTURER'S INSTRUCTIONS AND YOUR LOCAL REGULATIONS.
1. Reason for the JobRefer to the MPD TASK: 532102-01
GENERAL VISUAL INSPECTION OF CABIN FLOOR STRUCTURE, EXCLUDING AREAS BELOW GALLEYS AND TOILETS (IF INSTALLED), BETWEEN FR 24 AND FR 35
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | PAPER - MASKING |
| REFERENCE | DESIGNATION |
|---|---|
| (Material No.05RDA1) | Adhesive Film Tape-Masking - - |
| (Material No.08BAA9) | Non Aqueous Cleaner-General - - |
| (Material No.12ABB1) | Corrosion Preventive Compound-Water Displacing Hard Film - |
| (Material No.12ABC1) | Corrosion Preventive Compound_Water Displacing Soft Film - |
| (Material No.14SBA1) | Textile-Lint free Cotton - |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 231 | FWD PASSENGER COMPARTMENT |
| 232 | FWD PASSENGER COMPARTMENT |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 51-78-00-916-001-A | Application of Temporary Protection System (TPS) |
| TASK 53-22-12-000-001-A | Removal of the Cabin Floor Panels |
| TASK 53-22-12-400-001-A | Installation of the Cabin Floor Panels |
| SRM 51110001 | (for corrective action) |
| SRM 51220000 | (for corrective action) |
Subtask 53-21-00-010-085-A ** ON A/C NOT FOR ALL Subtask 53-21-00-110-089-A ** ON A/C NOT FOR ALL
B. Preparation of the Inspection Area
(1) Make sure that the inspection area is sufficiently clean to do a satisfactory inspection of the area.
(2) If it is not, clean the inspection area with Non Aqueous Cleaner-General - - (Material No.08BAA9) and a Textile-Lint free Cotton - (Material No.14SBA1) .
(3) If there is a Temporary Protection System (TPS) layer and if it does not let you do a satisfactory inspection, remove the TPS layer (Ref. AMM TASK 51-78-00-916-001).
4. Procedure(1) Make sure that the inspection area is sufficiently clean to do a satisfactory inspection of the area.
(2) If it is not, clean the inspection area with Non Aqueous Cleaner-General - - (Material No.08BAA9) and a Textile-Lint free Cotton - (Material No.14SBA1) .
(3) If there is a Temporary Protection System (TPS) layer and if it does not let you do a satisfactory inspection, remove the TPS layer (Ref. AMM TASK 51-78-00-916-001).
Subtask 53-21-00-210-074-A ** ON A/C NOT FOR ALL
A. Inspection
Cabin Floor Structure between FR24 and FR35.8 ** ON A/C NOT FOR ALL
Cabin Floor Structure between FR24 and FR35.8 ** ON A/C NOT FOR ALL
(1) Do a general visual inspection of the cabin floor structure, between FR24 and FR35.8. This inspection includes the seat tracks and cross beams. This inspection does not include the areas below the galleys and toilets and the emergency exit entrance area.
(2) Make sure that there is no:
(a) Corrosion damage:
- If you find corrosion damage, refer to the Structural Repair Manual SRM 51220000 for types of corrosion, inspection, removal and corrosion protection.
(b) Other damage (scratches, cracks, gouges, dents, creases):
- If you find other damage, refer to the Structural Repair Manual SRM 51110001 for damage classification and corrective action.
(3) Make sure that all the installations are attached correctly.
Subtask 53-21-00-916-064-A ** ON A/C NOT FOR ALL
Cabin Floor Structure between FR24 and FR35.8 ** ON A/C NOT FOR ALL
Cabin Floor Structure between FR24 and FR35.8 ** ON A/C NOT FOR ALL (2) Make sure that there is no:
(a) Corrosion damage:
- If you find corrosion damage, refer to the Structural Repair Manual SRM 51220000 for types of corrosion, inspection, removal and corrosion protection.
(b) Other damage (scratches, cracks, gouges, dents, creases):
- If you find other damage, refer to the Structural Repair Manual SRM 51110001 for damage classification and corrective action.
(3) Make sure that all the installations are attached correctly.
B. Application of the Temporary Protection System
(3) If the TPS layer has local damage, remove the damaged TPS layer and apply a new layer of Corrosion Preventive Compound_Water Displacing Soft Film - (Material No.12ABC1) or Corrosion Preventive Compound-Water Displacing Hard Film - (Material No.12ABB1) on the inspection area (Ref. AMM TASK 51-78-00-916-001).
(4) If, before the inspection, there was:
(5) Remove the PAPER - MASKING or the Adhesive Film Tape-Masking - - (Material No.05RDA1) .
5. Close-upCAUTION:
DO NOT APPLY TEMPORARY PROTECTION ON THE OXYGEN SYSTEMS.
MAKE SURE THAT THE TEMPORARY PROTECTION DOES NOT GET:
(1) If there is a TPS layer, do a check of the condition of the TPS layer (Ref. AMM TASK 51-78-00-916-001). - ON COMPOSITE PARTS, CONTROL CABLES, PULLEYS,TEFLON BEARINGS.
- ON LUBRICATED SURFACES.
- IN DRAIN VALVES OR OTHER ORIFICES.
NOTE: Airbus recommends that you always apply a new layer of TPS. This is to make sure that the TPS layer continues to give satisfactory corrosion protection. If, after the check, you think that the TPS layer is in the correct condition, you can apply a new layer as a spray on the existing layer.
(2) Put PAPER - MASKING or Adhesive Film Tape-Masking - - (Material No.05RDA1) on the equipment and fittings adjacent to the area. (3) If the TPS layer has local damage, remove the damaged TPS layer and apply a new layer of Corrosion Preventive Compound_Water Displacing Soft Film - (Material No.12ABC1) or Corrosion Preventive Compound-Water Displacing Hard Film - (Material No.12ABB1) on the inspection area (Ref. AMM TASK 51-78-00-916-001).
(4) If, before the inspection, there was:
- Removal of the TPS layer or
- Cleaning of the inspection area with high-pressure water, steam, solvents and/or cleaning agents
(5) Remove the PAPER - MASKING or the Adhesive Film Tape-Masking - - (Material No.05RDA1) .
Subtask 53-21-00-410-083-A ** ON A/C NOT FOR ALL
A. Close Access
(1) Install the cabin floor panels (Ref. AMM TASK 53-22-12-400-001).
(2) Make sure that the work area is clean and clear of tools and other items.
(1) Install the cabin floor panels (Ref. AMM TASK 53-22-12-400-001).
(2) Make sure that the work area is clean and clear of tools and other items.