W DOC AIRBUS | AMM A320F

Detailed Inspection of Forward Emergency Exit Skin Cut Out, Upper Corners, External Surface, LH


TASK 53-21-00-200-022-A
Detailed Inspection of Forward Emergency Exit Skin Cut Out, Upper Corners, External Surface, LH


WARNING: BE CAREFUL WHEN YOU USE CONSUMABLE MATERIALS. OBEY THE MATERIAL MANUFACTURER'S INSTRUCTIONS AND YOUR LOCAL REGULATIONS.
ZONE: 833
1. Reason for the Job
Refer to the MPD TASK: 532150-01
DETAILED INSPECTION OF FORWARD EMERGENCY EXIT SKIN CUT OUT, UPPER CORNERS, EXTERNAL SURFACE, LH
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
AR
ACCESS PLATFORM 4M (13 FT)-ADJUSTABLE
 B. Consumable Materials
REFERENCE
DESIGNATION
(Material No.08BAA9)
Non Aqueous Cleaner-General - -
(Material No.14SBA1)
Textile-Lint free Cotton -
 C. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
833
EMERGENCY EXITS
833
 D. Referenced Information
REFERENCE
DESIGNATION
TASK 52-22-00-010-002-A
Opening of the Emergency Exit Doors from the Outside
TASK 52-22-00-410-002-A
Closing of the Emergency Exit Doors from the Outside
SRM 51110001
(for corrective action)
SRM 51220001
(for corrective action)
SRM 512300
(for corrective action)
3. Job Set-up
Subtask 53-21-00-010-065-A ** ON A/C NOT FOR ALL
A. Get Access
   (1) Put an ACCESS PLATFORM 4M (13 FT)-ADJUSTABLE in position at the zone 833.
   (2) Open the forward emergency exit 833 (Ref. AMM TASK 52-22-00-010-002).
Subtask 53-21-00-110-062-A ** ON A/C NOT FOR ALL
B. Preparation of the Inspection Area
   (1) Make sure that the inspection area is sufficiently clean to do a satisfactory inspection of the area.
   (2) If it is not sufficiently clean, clean the inspection area with Non Aqueous Cleaner-General - - (Material No.08BAA9) and Textile-Lint free Cotton - (Material No.14SBA1) .
4. Procedure
Subtask 53-21-00-220-054-A ** ON A/C NOT FOR ALL
A. Inspection
   (1) Do a detailed inspection of the external structure of the upper corners of the forward emergency-exit skin-cut out for damage or discontinuities. This inspection is applicable on left side.
   (2) Make sure that there is no:
     (a) Corrosion damage:
If you find corrosion, refer to the Structural Repair Manual SRM 51220001 for the corrosion types, inspection, removal and subsequent corrosion protection.
     (b) Other damage (scratches, cracks, gouges, dents, creases):
If you find this type of damage, refer to the Structural Repair Manual SRM 51110001 for the damage types, classification and corrective action.
     (c) Paint layer damage:
If you find this type of damage, refer to Structural Repair Manual SRM 512300 for general data for paint layers.
5. Close-up
Subtask 53-21-00-410-064-A ** ON A/C NOT FOR ALL
A. Close Access
   (1) Make sure that the work area is clean and clear of tools and other items.
   (2) Close the forward emergency exit 833 (Ref. AMM TASK 52-22-00-410-002).
   (3) Remove the access platform(s).
[Rev.10 from 2021] 2026.04.02 06:28:57 UTC