Detailed Inspection of Forward Emergency Exit Cut Out Underneath the Scuff-plate, LH/RH
TASK 53-21-00-200-021-A
Detailed Inspection of Forward Emergency Exit Cut Out Underneath the Scuff-plate, LH/RH
Refer to the MPD TASK: 532119-01
DETAILED INSPECTION OF FORWARD EMERGENCY EXIT CUT OUT UNDERNEATH THE SCUFF-PLATE, LH/RH
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Consumable Materials
C. Work Zones and Access Panels
D. Referenced Information
3. Job Set-up
Subtask 53-21-00-010-062-A ** ON A/C NOT FOR ALL
Subtask 53-21-00-220-053-A ** ON A/C NOT FOR ALL
Subtask 53-21-00-410-061-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.02 06:28:56 UTC
Detailed Inspection of Forward Emergency Exit Cut Out Underneath the Scuff-plate, LH/RH
WARNING:
BE CAREFUL WHEN YOU USE CONSUMABLE MATERIALS. OBEY THE MATERIAL MANUFACTURER'S INSTRUCTIONS AND YOUR LOCAL REGULATIONS.
CAUTION:
DO NOT APPLY TEMPORARY PROTECTION SYSTEM (TPS) ON THE INSPECTION AREA. IF YOU APPLY TPS ON THE INSPECTION AREA, YOU CAN CAUSE DAMAGE TO THE AIRCRAFT.
ZONE: 230
1. Reason for the JobRefer to the MPD TASK: 532119-01
DETAILED INSPECTION OF FORWARD EMERGENCY EXIT CUT OUT UNDERNEATH THE SCUFF-PLATE, LH/RH
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | ACCESS PLATFORM 4M (13 FT)-ADJUSTABLE |
| REFERENCE | DESIGNATION |
|---|---|
| (Material No.08BAA9) | Non Aqueous Cleaner-General - - |
| (Material No.14SBA1) | Textile-Lint free Cotton - |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 230 | FWD PASSENGER COMPARTMENT |
| 833, 843 |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 51-78-00-916-001-A | Application of Temporary Protection System (TPS) |
| TASK 52-22-00-010-002-A | Opening of the Emergency Exit Doors from the Outside |
| TASK 52-22-00-410-002-A | Closing of the Emergency Exit Doors from the Outside |
| TASK 53-25-41-000-001-A | Removal of the Forward Emergency-Exit-Door Scuff-Plates |
| TASK 53-25-41-400-001-A | Installation of the Forward Emergency-Exit-Door Scuff-Plates |
| SRM 51110001 | (for corrective action) |
| SRM 51220001 | (for corrective action) |
Subtask 53-21-00-010-062-A ** ON A/C NOT FOR ALL
A. Get Access
(1) Put an ACCESS PLATFORM 4M (13 FT)-ADJUSTABLE in position at zone 231 (232).
(2) Open the forward emergency exit door 833 ( 843) (Ref. AMM TASK 52-22-00-010-002).
(3) Remove the scuff-plate below the forward emergency exit (Ref. AMM TASK 53-25-41-000-001) (left and right sides).
Subtask 53-21-00-110-053-A ** ON A/C NOT FOR ALL (1) Put an ACCESS PLATFORM 4M (13 FT)-ADJUSTABLE in position at zone 231 (232).
(2) Open the forward emergency exit door 833 ( 843) (Ref. AMM TASK 52-22-00-010-002).
(3) Remove the scuff-plate below the forward emergency exit (Ref. AMM TASK 53-25-41-000-001) (left and right sides).
B. Preparation of the Inspection Area
(1) Make sure that the inspection area is sufficiently clean to do a satisfactory inspection of the area.
(2) If it is not, clean the inspection area with Non Aqueous Cleaner-General - - (Material No.08BAA9) and a Textile-Lint free Cotton - (Material No.14SBA1) .
(3) Make sure that there is no Temporary Protection System (TPS) layer and if there is a TPS layer, remove it (Ref. AMM TASK 51-78-00-916-001).
4. Procedure(1) Make sure that the inspection area is sufficiently clean to do a satisfactory inspection of the area.
(2) If it is not, clean the inspection area with Non Aqueous Cleaner-General - - (Material No.08BAA9) and a Textile-Lint free Cotton - (Material No.14SBA1) .
(3) Make sure that there is no Temporary Protection System (TPS) layer and if there is a TPS layer, remove it (Ref. AMM TASK 51-78-00-916-001).
Subtask 53-21-00-220-053-A ** ON A/C NOT FOR ALL
A. Inspection
(1) Do a detailed inspection of the internal structure below the scuff plate.
(2) Make sure that there is no:
(a) Corrosion damage:
- If you find corrosion damage, refer to the Structural Repair Manual SRM 51220001 for types of corrosion, inspection, removal and corrosion protection.
(b) Other damage (scratches, cracks, gouges, dents, creases):
- If you find other damage, refer to the Structural Repair Manual SRM 51110001 for damage classification and corrective action.
5. Close-up(1) Do a detailed inspection of the internal structure below the scuff plate.
(2) Make sure that there is no:
(a) Corrosion damage:
- If you find corrosion damage, refer to the Structural Repair Manual SRM 51220001 for types of corrosion, inspection, removal and corrosion protection.
(b) Other damage (scratches, cracks, gouges, dents, creases):
- If you find other damage, refer to the Structural Repair Manual SRM 51110001 for damage classification and corrective action.
Subtask 53-21-00-410-061-A ** ON A/C NOT FOR ALL
A. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Install the scuff-plates under the forward emergency exit (Ref. AMM TASK 53-25-41-400-001) (left and right sides).
(3) Close the forward emergency exit 833 ( 843) (Ref. AMM TASK 52-22-00-410-002).
(4) Remove the access platform(s).
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Install the scuff-plates under the forward emergency exit (Ref. AMM TASK 53-25-41-400-001) (left and right sides).
(3) Close the forward emergency exit 833 ( 843) (Ref. AMM TASK 52-22-00-410-002).
(4) Remove the access platform(s).
Scuff plates of the FWD Emergency Exit