W DOC AIRBUS | AMM A320F

Detailed Inspection of Door Stop Fittings on FR 35.1 and FR 35.2A, LH/RH


TASK 53-21-00-200-019-A
Detailed Inspection of Door Stop Fittings on FR 35.1 and FR 35.2A, LH/RH


WARNING: BE CAREFUL WHEN YOU USE CONSUMABLE MATERIALS. OBEY THE MATERIAL MANUFACTURER'S INSTRUCTIONS AND YOUR LOCAL REGULATIONS.
ZONE: 231
ZONE: 232
1. Reason for the Job
Refer to the MPD TASK: 532114-01
DETAILED INSPECTION OF DOOR STOP FITTINGS ON FR 35.1 AND FR 35.2A, LH/RH
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
AR
ACCESS PLATFORM 5M (16 FT)- ADJUSTABLE
 B. Consumable Materials
REFERENCE
DESIGNATION
(Material No.08BAA9)
Non Aqueous Cleaner-General - -
(Material No.14SBA1)
Textile-Lint free Cotton -
 C. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
231
FWD PASSENGER COMPARTMENT
232
FWD PASSENGER COMPARTMENT
833, 843
 D. Referenced Information
REFERENCE
DESIGNATION
TASK 25-23-47-000-004-A
Removal of the Door Frame Linings of the LH FWD Emergency Exit Door, zone 231
TASK 25-23-47-000-009-A
Removal of the Door Frame Linings of the Right Forward Emergency Exit Door from Zone 232
TASK 25-23-47-400-004-A
Installation of the Door Frame Linings of the LH FWD Emergency Exit Door, zone 231
TASK 25-23-47-400-009-A
Installation of the Door Frame Linings of the Right Forward Emergency Exit Door in Zone 232
TASK 52-22-00-010-001-A
Opening of the Emergency Exit Doors from the Passenger Compartment
TASK 52-22-00-410-001-A
Closing of the Emergency Exit Doors from the Passenger Compartment
SRM 51110001
(for corrective action)
SRM 51220001
(for corrective action)
3. Job Set-up
Subtask 53-21-00-010-060-A ** ON A/C NOT FOR ALL
A. Get Access
   (1) Put an ACCESS PLATFORM 5M (16 FT)- ADJUSTABLE in position at the zone 231(232).
   (2) Open the forward emergency exit door 833 ( 843), (Ref. AMM TASK 52-22-00-010-001).
   (3) Remove the door frame linings (Ref. AMM TASK 25-23-47-000-004) (Ref. AMM TASK 25-23-47-000-009).
Subtask 53-21-00-110-051-A ** ON A/C NOT FOR ALL
B. Cleaning of the Structure
WARNING: BE CAREFUL WHEN YOU USE CONSUMABLE MATERIALS. OBEY THE MATERIAL MANUFACTURER'S INSTRUCTIONS AND YOUR LOCAL REGULATIONS.
   (1) Clean the inspection area with a Non Aqueous Cleaner-General - - (Material No.08BAA9) and a lint-free cotton cloth Textile-Lint free Cotton - (Material No.14SBA1) , if necessary.
4. Procedure
Subtask 53-21-00-220-051-A ** ON A/C NOT FOR ALL
A. Inspection
   (1) Do a detailed inspection of the structure of the door stop fittings.
   (2) Make sure that there is no:
     (a) Corrosion damage:
- If you find corrosion damage, refer to the Structural Repair Manual SRM 51220001 for types of corrosion, inspection, removal and corrosion protection.
     (b) Other damage (scratches, cracks, gouges, dents, creases):
- If you find other damage, refer to the Structural Repair Manual SRM 51110001 for damage classification and corrective action.
5. Close-up
Subtask 53-21-00-410-059-A ** ON A/C NOT FOR ALL
A. Close Access
   (1) Make sure that the work area is clean and clear of tools and other items.
   (2) Install the door frame linings (Ref. AMM TASK 25-23-47-400-004) (Ref. AMM TASK 25-23-47-400-009).
   (3) Close the forward emergency exit 833 ( 843), (Ref. AMM TASK 52-22-00-410-001).
   (4) Remove the access platform(s).
[Rev.10 from 2021] 2026.04.02 06:28:56 UTC