W DOC AIRBUS | AMM A320F

Installation of the Collector Grid and the Container


TASK 53-19-41-400-001-A
Installation of the Collector Grid and the Container


ZONE: 120
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
AR
ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE
No specific
Torque wrench: range to between 0.308 and 0.252 m.daN (27.26 and 22.30 lbf.in ) T
 B. Consumable Materials
REFERENCE
DESIGNATION
(Material No.06AAB1)
Polysulfide Sealant-General Purpose Fillet -
 C. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
120
AVIONICS COMPARTMENT
812
 D. Referenced Information
REFERENCE
DESIGNATION
F Collector Grid and Container ** ON A/C NOT FOR ALL
F Collector Grid and Container ** ON A/C NOT FOR ALL
3. Job Set-up
Subtask 53-19-41-860-050-A ** ON A/C NOT FOR ALL
A. Aircraft Maintenance Configuration
   (1) Make sure that the ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE is in position at zone 812.
   (2) Make sure that the avionics-compartment access door 812 is open.
4. Procedure
Subtask 53-19-41-840-050-A ** ON A/C NOT FOR ALL
A. Preparation for Installation
F Collector Grid and Container ** ON A/C NOT FOR ALL
F Collector Grid and Container ** ON A/C NOT FOR ALL
   (1) Flush the collector grid (2) and the container (9).
   (2) Remove and clean the strainers (10) of the container.
   (3) Dry the collector grid (2), the container (9) and the strainers (10).
   (4) Install the strainers (10).
   (5) Clean the component interfaces and the adjacent area.
Subtask 53-19-41-420-050-A ** ON A/C NOT FOR ALL
B. Installation of the Collector Grid and the Container
F Collector Grid and Container ** ON A/C NOT FOR ALL
   (1) Put the container (9) in position.
   (2) Install the washers (3) and the screws (4).
   (3) Install the washers (5) and the screws (6).
   (4) Tighten the screws (4) and (6).
   (5) Make sure that the line end-fittings are serviceable.
   (6) Connect the ducts (8).
   (7) Install the clamps (7) and TORQUE the clamps to between 0.308 and 0.252 m.daN (27.26 and 22.30 lbf.in ) T.
   (8) Put the collector grid (2) in position.
   (9) Install the screws (1) and tighten.
   (10) Apply a layer of Polysulfide Sealant-General Purpose Fillet - (Material No.
06AAB1) between the structure and the grid rack assembly, on the ends of the screws (4) and (6).
Subtask 53-19-41-420-050-B ** ON A/C NOT FOR ALL
B. Installation of the Collector Grid and the Container
F Collector Grid and Container ** ON A/C NOT FOR ALL
   (1) Put the container (9) in position.
   (2) Install the washers (3) and the screws (4).
   (3) Install the washers (5) and the screws (6).
   (4) Tighten the screws (4) and (6).
   (5) Make sure that the line end-fittings are serviceable.
   (6) Connect the ducts (8).
   (7) Install the cable-tie (7).
   (8) Put the collector grid (2) in position.
   (9) Install the screws (1) and tighten.
   (10) Apply a layer of Polysulfide Sealant-General Purpose Fillet - (Material No.06AAB1) between the structure and the grid rack assembly, on the ends of the screws (4) and (6).
5. Close-up
Subtask 53-19-41-410-050-A ** ON A/C NOT FOR ALL
A. Close Access
   (1) Make sure that the work area is clean and clear of tools and other items.
   (2) Close the access door 812.
   (3) Remove the access platform(s).