Operational Check of the Cockpit Drainage Pipe
TASK 53-19-00-710-001-A
Operational Check of the Cockpit Drainage Pipe
Refer to the MPD TASK: 531900-02
OPERATIONAL CHECK OF THE COCKPIT DRAINAGE PIPE
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 53-19-00-010-054-A
Subtask 53-19-00-710-050-A
Subtask 53-19-00-410-054-A
[Rev.10 from 2021]
2026.04.02 06:28:55 UTC
Operational Check of the Cockpit Drainage Pipe
ZONE: 120
1. Reason for the JobRefer to the MPD TASK: 531900-02
OPERATIONAL CHECK OF THE COCKPIT DRAINAGE PIPE
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE |
| No specific | AR | FLASHLIGHT |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 120 | AVIONICS COMPARTMENT |
| 824 |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 52-41-00-010-002-A | Open the Avionics Compartment Doors for Access |
| TASK 53-12-13-000-001-A | Removal of the avionics compartment floor panels |
| TASK 53-12-13-400-001-A | Installation of the avionics compartment floor panels |
| TASK 53-19-41-000-001-A | Removal of the Collector Grid and the Container |
| TASK 53-19-41-400-001-A | Installation of the Collector Grid and the Container |
Subtask 53-19-00-010-054-A
A. Get Access
(1) Remove the collector grid (Ref. AMM TASK 53-19-41-000-001).
(2) Put an ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE in position at zone 824.
(3) Open the avionics compartment door 824 (Ref. AMM TASK 52-41-00-010-002).
(4) Remove the avionics-compartment floor panels (Ref. AMM TASK 53-12-13-000-001).
4. Procedure(1) Remove the collector grid (Ref. AMM TASK 53-19-41-000-001).
(2) Put an ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE in position at zone 824.
(3) Open the avionics compartment door 824 (Ref. AMM TASK 52-41-00-010-002).
(4) Remove the avionics-compartment floor panels (Ref. AMM TASK 53-12-13-000-001).
Subtask 53-19-00-710-050-A
A. Inspection
(1) In the avionics compartment:
(a) Use a FLASHLIGHT to make sure that the drainage pipe connectors on the outputs of the fluid collector are in the correct condition.
(b) Do a detailed visual inspection of the cockpit drainage pipe:
5. Close-up(1) In the avionics compartment:
(a) Use a FLASHLIGHT to make sure that the drainage pipe connectors on the outputs of the fluid collector are in the correct condition.
(b) Do a detailed visual inspection of the cockpit drainage pipe:
- fill the fluid collector with water and do a check of the drainage pipe for leaks.
Subtask 53-19-00-410-054-A
A. Close Access
(1) Install the collector grid (Ref. AMM TASK 53-19-41-400-001).
(2) Install the avionics-compartment floor panels (Ref. AMM TASK 53-12-13-400-001).
(3) Make sure that the work area is clean and clear of tools and other items.
(4) Remove the access platform(s).
(1) Install the collector grid (Ref. AMM TASK 53-19-41-400-001).
(2) Install the avionics-compartment floor panels (Ref. AMM TASK 53-12-13-400-001).
(3) Make sure that the work area is clean and clear of tools and other items.
(4) Remove the access platform(s).
Cockpit Drainage Pipe