Installation of the Hinge Assembly of the NLG Aft Door-Assembly
TASK 53-16-11-400-802-A
Installation of the Hinge Assembly of the NLG Aft Door-Assembly
A. Fixtures, Tools, Test and Support Equipment
B. Consumable Materials
C. Work Zones and Access Panels
D. Expendable Parts
E. Referenced Information
3. Job Set-up
Subtask 53-16-11-010-054-A
Subtask 53-16-11-420-052-A ** ON A/C NOT FOR ALL
Subtask 53-16-11-410-052-A
[Rev.10 from 2021]
2026.04.02 06:28:54 UTC
Installation of the Hinge Assembly of the NLG Aft Door-Assembly
WARNING:
BE CAREFUL WHEN YOU USE CONSUMABLE MATERIALS. OBEY THE MATERIAL MANUFACTURER'S INSTRUCTIONS AND YOUR LOCAL REGULATIONS.
1. Reason for the JobNOTE: Two persons are necessary to do this task.
2. Job Set-up InformationA. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 1 | ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE |
| No specific | Torque wrench: range to between 4.4 and 3.5 m.daN (32.45 and 25.81 lbf.ft ) ![]() |
| REFERENCE | DESIGNATION |
|---|---|
| (Material No.06LCG9) | Non Hardening Jointing Putty-Medium Temp. Area - - |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 123 | NOSE GEAR WELL |
| 124 | NOSE GEAR WELL |
| FIG.ITEM | DESIGNATION | IPC-CSN |
|---|---|---|
| 3 | COTTER PIN | AIPC 53-16-01-12-020 |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 21-20-00-010-001-A | Removal of the Air-Conditioning Distribution Ducts |
| TASK 21-20-00-410-001-A | Installation of the Air-Conditioning Distribution Ducts |
| TASK 32-22-13-010-001-A | Removal of the NLG Aft Door-Assembly for Access |
| TASK 32-22-13-410-001-A | Installation of the NLG Aft Door-Assembly after Removal for Access |
| TASK 52-41-00-010-002-A | Open the Avionics Compartment Doors for Access |
| TASK 52-41-00-410-002-A | Close the Avionics Compartment Doors after Access |
Subtask 53-16-11-010-054-A
A. Get Access
(1) Make sure that the applicable NLG aft door-assembly is removed (Ref. AMM TASK 32-22-13-010-001).
(2) Make sure that applicable access door 812(824) is open (Ref. AMM TASK 52-41-00-010-002).
(3) Make sure that the ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE is in position at zone 123(124).
4. Procedure(1) Make sure that the applicable NLG aft door-assembly is removed (Ref. AMM TASK 32-22-13-010-001).
(2) Make sure that applicable access door 812(824) is open (Ref. AMM TASK 52-41-00-010-002).
(3) Make sure that the ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE is in position at zone 123(124).
CAUTION:
BE VERY CAREFUL WHEN YOU DO WORK ON OR NEAR THE AIR-CONDITIONING DUCTS. THE DUCTS ARE MADE OF THIN MATERIAL AND YOU CAN EASILY BREAK THEM.
(4) If necessary, make sure that the applicable air-conditioning distribution duct(s) is(are) removed (Ref. AMM TASK 21-20-00-010-001).Subtask 53-16-11-420-052-A ** ON A/C NOT FOR ALL
A. Installation of the Hinge Assembly of the NLG Aft Door-Assembly
(1) Apply Non Hardening Jointing Putty-Medium Temp. Area - - (Material No.06LCG9) on the hinge assembly (5).
(2) Install the hinge assembly (5), the washer (1) and the nut (2) on the structure (4).
(3) TORQUE the nut (2) to between 4.4 and 3.5 m.daN (32.45 and 25.81 lbf.ft )
.
(4) Safety the nut (2) with the new AIPC 53-16-01-12-020 COTTER PIN (3).
Subtask 53-16-11-420-052-B ** ON A/C NOT FOR ALL (1) Apply Non Hardening Jointing Putty-Medium Temp. Area - - (Material No.06LCG9) on the hinge assembly (5).
(2) Install the hinge assembly (5), the washer (1) and the nut (2) on the structure (4).
(3) TORQUE the nut (2) to between 4.4 and 3.5 m.daN (32.45 and 25.81 lbf.ft )
.(4) Safety the nut (2) with the new AIPC 53-16-01-12-020 COTTER PIN (3).
A. Installation of the Hinge Assembly of the NLG Aft Door-Assembly
(1) Apply Non Hardening Jointing Putty-Medium Temp. Area - - (Material No.06LCG9) on the hinge assembly (6).
(2) Install the washer (5), the hinge assembly (6), the washer (1) and the nut (2) on the structure (4).
(3) TORQUE the nut (2) to between 4.4 and 3.5 m.daN (32.45 and 25.81 lbf.ft )
.
(4) Safety the nut (2) with the new AIPC 53-16-01-12-020 COTTER PIN (3).
5. Close-up(1) Apply Non Hardening Jointing Putty-Medium Temp. Area - - (Material No.06LCG9) on the hinge assembly (6).
(2) Install the washer (5), the hinge assembly (6), the washer (1) and the nut (2) on the structure (4).
(3) TORQUE the nut (2) to between 4.4 and 3.5 m.daN (32.45 and 25.81 lbf.ft )
.(4) Safety the nut (2) with the new AIPC 53-16-01-12-020 COTTER PIN (3).
Subtask 53-16-11-410-052-A
A. Close Access
(2) Remove the access platform(s).
(3) Close applicable access door 812(824) (Ref. AMM TASK 52-41-00-410-002).
(4) Install the removed NLG aft door-assembly (Ref. AMM TASK 32-22-13-410-001).
CAUTION:
BE VERY CAREFUL WHEN YOU DO WORK ON OR NEAR THE AIR-CONDITIONING DUCTS. THE DUCTS ARE MADE OF THIN MATERIAL AND YOU CAN EASILY BREAK THEM.
(1) If removed, install the applicable air-conditioning distribution duct(s) (Ref. AMM TASK 21-20-00-410-001).(2) Remove the access platform(s).
(3) Close applicable access door 812(824) (Ref. AMM TASK 52-41-00-410-002).
(4) Install the removed NLG aft door-assembly (Ref. AMM TASK 32-22-13-410-001).
Hinge Assembly of the NLG Aft Door-Assembly