W DOC AIRBUS | AMM A320F

Installation of the Protective Shields - FR1


TASK 53-11-41-400-001-A
Installation of the Protective Shields - FR1


CAUTION: DO NOT USE THE LOCALIZER ANTENNA AT THE BOTTOM OF THE RADOME AS A SUPPORT.
ZONE: 110
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
AR
ACCESS PLATFORM 5M (16 FT)- ADJUSTABLE
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
110
RADOME (NOSE CONE TO FR 1)
110AL
 C. Referenced Information
REFERENCE
DESIGNATION
TASK 24-42-00-861-001-A
Energize the Ground Service Network from the External Power
TASK 24-42-00-862-001-A
De-energize the Ground Service Network Supplied from the External Power
TASK 34-41-41-400-001-A
Installation of the Wave Guide Assembly
TASK 53-15-11-010-001-A
Opening of the Radome
TASK 53-15-11-410-001-A
Closing of the Radome
3. Job Set-up
Subtask 53-11-41-860-050-A
A. Aircraft Maintenance Configuration
   (1) Make sure that the ground service network is energized
(Ref. AMM TASK 24-42-00-861-001).
   (2) Make sure that ACCESS PLATFORM 5M (16 FT)- ADJUSTABLE is in position below the radome in the zone 110.
WARNING: DO NOT OPEN THE RADOME IF THE WIND SPEED IS MORE THAN 25 KNOTS.
   (3) Make sure that the radome 110AL is open (Ref. AMM TASK 53-15-11-010-001).
Subtask 53-11-41-865-051-A
B. Make sure that this(these) circuit breaker(s) is(are) open, safetied and tagged:
PANELDESIGNATIONFINLOCATION
** ON A/C ALL
121VUCOM NAV/RADAR/15SQ1K13
** ON A/C NOT FOR ALL
121VUCOM NAV/RADAR/25SQ2K14
4. Procedure
Subtask 53-11-41-420-050-C
A. Installation of the Protective Shields
   (1) Put the shields (1), (4) and (5) in position.
   (2) Install the screws (3) and the washers (2).
   (3) Tighten the screws (3).
5. Close-up
Subtask 53-11-41-865-052-A
A. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C ALL
121VUCOM NAV/RADAR/15SQ1K13
** ON A/C NOT FOR ALL
121VUCOM NAV/RADAR/25SQ2K14
Subtask 53-11-41-410-050-A
B. Close Access
   (1) Make sure that the work area is clean and clear of tools and other items.
   (2) Install the wave guide assembly (Ref. AMM TASK 34-41-41-400-001).
   (3) Close the radome 110AL (Ref. AMM TASK 53-15-11-410-001).
   (4) Remove the access platform(s).
   (5) Remove the WARNING NOTICE(S).
Subtask 53-11-41-862-050-A
C. De-energize the ground service network
(Ref. AMM TASK 24-42-00-862-001)
[Rev.10 from 2021] 2026.04.02 06:28:49 UTC