W DOC AIRBUS | AMM A320F

Detailed Inspection of Rain Gutter Area over Forward PAX Door, LH/RH


TASK 53-11-00-220-814-A
Detailed Inspection of Rain Gutter Area over Forward PAX Door, LH/RH


WARNING: BE CAREFUL WHEN YOU USE CONSUMABLE MATERIALS. OBEY THE MATERIAL MANUFACTURER'S INSTRUCTIONS AND YOUR LOCAL REGULATIONS.
ZONE: 221
ZONE: 222
1. Reason for the Job
Refer to the MPD TASK: 531142-01
DETAILED INSPECTION OF RAIN GUTTER AREA OVER FORWARD PAX DOOR, LH/RH

NOTE: This task is an alternative to MPD task 531142-02.
NOTE: The effectivity of this task is "ALL". To know if this task is applicable to your aircraft, refer to the MPD task applicability. The information on weight variant groups is given in the MPD and SRM introductions.
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
1
ACCESS PLATFORM 5M (16 FT)- ADJUSTABLE
 B. Consumable Materials
REFERENCE
DESIGNATION
(Material No.08BAA9)
Non Aqueous Cleaner-General - -
(Material No.14SBA1)
Textile-Lint free Cotton -
 C. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
221
FWD CAB UTILITY AREA
222
FWD CAB UTILITY AREA
831, 841
 D. Referenced Information
REFERENCE
DESIGNATION
SRM 511100
(for corrective action)
SRM 512200
(for corrective action)
SRM 512300
(for corrective action)
3. Job Set-up
Subtask 53-11-00-010-133-A
A. Get Access
   (1) Put the ACCESS PLATFORM 5M (16 FT)- ADJUSTABLE in position in front of passenger/crew door 831 ( 841).
Subtask 53-11-00-110-151-A
B. Preparation of the Inspection Area
   (1) Make sure that the inspection area is sufficiently clean to do a satisfactory inspection of the area.
   (2) If not, clean the inspection area with Non Aqueous Cleaner-General - - (Material No.08BAA9) and the Textile-Lint free Cotton - (Material No.14SBA1) .
4. Procedure
Subtask 53-11-00-220-104-A
A. Inspection
   (1) Do a detailed inspection of the rain gutter area, on the left and right forward passenger-doors, for damage or discontinuities.
   (2) Make sure that there is no:
     (a) Corrosion damage:
If you find corrosion, refer to the Structural Repair Manual ( SRM 512200) for the corrosion types, inspection, removal and subsequent corrosion protection.
     (b) Other damage (scratches, cracks, gouges, dents, creases):
If you find this type of damage, refer to the Structural Repair Manual ( SRM 511100) for the damage types, classification and corrective action.
     (c) Paint layer damage:
If you find this type of damage, refer to the Structural Repair Manual ( SRM 512300) for general data for paint layers.
5. Close-up
Subtask 53-11-00-410-132-A
A. Close Access
   (1) Make sure that the work area is clean and clear of tools and other items.
   (2) Remove the access platform(s).
[Rev.10 from 2021] 2026.04.02 06:28:47 UTC