W DOC AIRBUS | AMM A320F

Detailed Inspection of Central/Lateral Window Frame Junction Upper Area around Fastener Hole LHS/RHS


TASK 53-11-00-220-805-A
Detailed Inspection of Central/Lateral Window Frame Junction Upper Area around Fastener Hole LHS/RHS


WARNING: BE CAREFUL WHEN YOU USE CONSUMABLE MATERIALS. OBEY THE MATERIAL MANUFACTURER'S INSTRUCTIONS AND YOUR LOCAL REGULATIONS.
ZONE: 211
ZONE: 212
1. Reason for the Job
Refer to the MPD TASK: 531125-02
DETAILED INSPECTION OF CENTRAL/LATERAL WINDOW FRAME JUNCTION UPPER AREA AROUND FASTENER HOLE LHS/RHS
NOTE: The effectivity of this task is "ALL". To know if this task is applicable to your aircraft, refer to the MPD task applicability and the weight variant data given in the SRM introduction.
2. Job Set-up Information
 A. Consumable Materials
REFERENCE
DESIGNATION
(Material No.08BAA9)
Non Aqueous Cleaner-General - -
(Material No.14SBA1)
Textile-Lint free Cotton -
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
211
COCKPIT
212
COCKPIT
 C. Referenced Information
REFERENCE
DESIGNATION
TASK 56-12-11-010-001-A
Opening of the Cockpit Sliding Windows
TASK 56-12-11-410-001-A
Closing of the Cockpit Sliding Windows
SRM 511100
(for corrective action)
SRM 512200
(for corrective action)
3. Job Set-up
Subtask 53-11-00-010-111-A
A. Get Access
   (1) Open the sliding window (Ref. AMM TASK 56-12-11-010-001).
Subtask 53-11-00-110-130-A
B. Cleaning of the Structure
   (1) Clean the inspection areas with Non Aqueous Cleaner-General - - (Material No.08BAA9) and Textile-Lint free Cotton - (Material No.14SBA1) , if necessary.
4. Procedure
Subtask 53-11-00-220-097-A
A. Inspection
   (1) Do a detailed inspection of the fastener hole on the upper area of the central/lateral window-frame junction. Do this inspection on the left and right sides.
   (2) Make sure that there is no:
     (a) Corrosion damage:
  • If you find corrosion damage, refer to Structural Repair Manual SRM 512200 for types of corrosion, inspection, removal and corrosion protection.
     (b) Other damage (scratches, cracks, gouges, dents, creases):
  • If you find other damage, refer to Structural Repair Manual SRM 511100 for damage classification and corrective action.
5. Close-up
Subtask 53-11-00-410-111-A
A. Close Access
   (1) Make sure that the work area is clean and clear of tool(s) and other items.
   (2) Close the sliding window (Ref. AMM TASK 56-12-11-410-001).