W DOC AIRBUS | AMM A320F

General Visual Inspection of Attachment to Skin Panel, FR 16, Stringer 3 LH/RH


TASK 53-11-00-210-818-A
General Visual Inspection of Attachment to Skin Panel, FR 16, Stringer 3 LH/RH


WARNING: BE CAREFUL WHEN YOU USE CONSUMABLE MATERIALS. OBEY THE MATERIAL MANUFACTURER'S INSTRUCTIONS AND YOUR LOCAL REGULATIONS.
ZONE: 220
1. Reason for the Job
Refer to the MPD TASK: 531113-01
GENERAL VISUAL INSPECTION OF ATTACHMENT TO SKIN PANEL, FR 16, STRINGER 3 LH/RH
NOTE: The effectivity of this task is "ALL".To know if this task is applicable to your aircraft, refer to the MPD task applicability.
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
1
ACCESS PLATFORM 6M (20 FT) - ADJUSTABLE
 B. Consumable Materials
REFERENCE
DESIGNATION
(Material No.08BAA9)
Non Aqueous Cleaner-General - -
(Material No.14SBA1)
Textile-Lint free Cotton -
 C. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
220
FWD CAB UTILITY AREAS
 D. Referenced Information
REFERENCE
DESIGNATION
TASK 51-78-00-916-001-A
Application of Temporary Protection System (TPS)
SRM 511100
(for corrective action)
SRM 512200
(for corrective action)
SRM 512300
(for corrective action)
3. Job Set-up
Subtask 53-11-00-010-108-A
A. Get Access
   (1) Put the ACCESS PLATFORM 6M (20 FT) - ADJUSTABLE in position at zone 220.
Subtask 53-11-00-110-127-A
B. Preparation of the Inspection Area
   (1) Make sure that the inspection area is sufficiently clean to do a satisfactory inspection of the area.
   (2) If not, clean the inspection area with Non Aqueous Cleaner-General - - (Material No.08BAA9) and the Textile-Lint free Cotton - (Material No.14SBA1) .
   (3) If there is a temporary protection system (TPS) layer and if it does not let you do a satisfactory inspection, remove the TPS layer (Ref. AMM TASK 51-78-00-916-001).
4. Procedure
Subtask 53-11-00-210-097-A
A. Inspection
   (1) Do a general visual inspection of the external surface of the attachment on the skin panel for damage or discontinuities. This inspection is applicable to FR16, stringer 3, left and right sides.
   (2) Make sure that there is no:
     (a) Corrosion:
If you find corrosion, refer to the Structural Repair Manual SRM 512200 for the corrosion types, inspection, removal and subsequent corrosion protection.
     (b) Other damage (scratches, cracks, gouges, dents, creases):
If you find this type of damage, refer to the Structural Repair Manual SRM 511100 for the damage types, classification and corrective action.
     (c) Paint layer damage:
If you find this type of damage, refer to the Structural Repair Manual SRM 512300 for general data for paint layers.
Subtask 53-11-00-916-094-A
CAUTION: DO NOT APPLY TEMPORARY PROTECTION SYSTEM (TPS) TYPE 3 ON THE MOVABLE COMPONENTS. USE ONLY TPS TYPE 1 GRADE 2. IF YOU DO NOT OBEY THIS INSTRUCTION, THE MECHANISMS WILL NOT OPERATE CORRECTLY.
B. Check and Application of the TPS Layer
NOTE: There is no special requirement about the TPS layer application in this area. The operator can apply TPS or let the surface stay without protection.
   (1) If you removed the TPS at the ”Preparation of the Inspection Area” paragraph, and you make the decision to apply a TPS layer, ( (Ref. AMM TASK 51-78-00-916-001)).
   (2) If you did not remove the TPS at the ”Preparation of the Inspection Area” paragraph, do a check of the condition and integrity of the TPS layer ( (Ref. AMM TASK 51-78-00-916-001)) and make the decision to apply a new TPS layer or not.
   (3) If the TPS layer has local damage, remove the damaged TPS layer and apply a new layer of TPS ( (Ref. AMM TASK 51-78-00-916-001)).
5. Close-up
Subtask 53-11-00-410-149-A
A. Close Access
   (1) Make sure that the work area is clean and clear of tools and other items.
   (2) Remove all the fixtures, tools, test and support equipment used during this procedure.
   (3) Remove the access platform(s).
[Rev.10 from 2021] 2026.04.02 06:28:45 UTC