W DOC AIRBUS | AMM A320F

Clean Door Girt Bar Fitting Stop Levers


TASK 53-11-00-210-034-A
Clean Door Girt Bar Fitting Stop Levers


ZONE: 221
ZONE: 222
ZONE: 261
ZONE: 262
1. Reason for the Job
Refer to the MPD TASK: 256241-05
CLEAN DOOR GIRT BAR FITTING STOP LEVERS

2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
AR
ACCESS PLATFORM 4M (13 FT)-ADJUSTABLE
No specific
AR
VACUUM CLEANER
 B. Consumable Materials
REFERENCE
DESIGNATION
(Material No.08BAA9)
Non Aqueous Cleaner-General - -
(Material No.14SBA1)
Textile-Lint free Cotton -
 C. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
221
FWD CAB UTILITY AREA
222
FWD CAB UTILITY AREA
261
AFT CABIN UTILITY AREA
262
AFT CABIN UTILITY AREA
831, 832, 841, 842
 D. Referenced Information
REFERENCE
DESIGNATION
TASK 52-10-00-010-001-A
Opening of the Passenger/Crew Door
TASK 52-10-00-410-001-A
Closing of the Passenger/Crew Door
TASK 52-11-31-000-003-A
Removal of the Girt Bar Fittings
TASK 52-11-31-400-003-A
Installation of the Girt Bar Fittings
TASK 52-13-31-000-003-A
Removal of the Girt Bar Fittings
TASK 52-13-31-400-003-A
Installation of the Girt Bar Fittings
3. Job Set-up
Subtask 53-11-00-010-070-A
A. Get Access
   (1) Put the ACCESS PLATFORM 4M (13 FT)-ADJUSTABLE in position at the left and right, aft and forward passenger/crew door.
   (2) Open the door 831 832 841 842, (Ref. AMM TASK 52-10-00-010-001).
4. Procedure
Subtask 53-11-00-110-050-A
A. Cleaning
   (1) Clean the girt-bar fitting stop-levers and their adjacent areas with a VACUUM CLEANER to remove the dirt and dust in these areas.
NOTE: Do not apply grease on the cleaned area.
Subtask 53-11-00-720-050-A
B. Test
   (1) Press the lever (1) down and release it to do an operational test.
   (2) Make sure that the lever (1) comes up quickly.
   (3) If the operational test is unsatisfactory:
     (a) Clean the lever (1) with Non Aqueous Cleaner-General - - (Material No.08BAA9) and a lint-free cotton cloth Textile-Lint free Cotton - (Material No.14SBA1) .
     (b) Press the lever (1) down again and release it to do the operational test again.
   (4) If the operational test is again unsatisfactory:
     (a) Remove the girt bar fitting (Ref. AMM TASK 52-11-31-000-003) or (Ref. AMM TASK 52-13-31-000-003)
     (b) Clean all the components
     (c) Install the girt bar fitting (Ref. AMM TASK 52-11-31-400-003) or (Ref. AMM TASK 52-13-31-400-003)
5. Close-up
Subtask 53-11-00-410-070-A
A. Close Access
   (1) Make sure that the work area is clean and clear of tools and other items.
   (2) Close the door 831 832 841 842, (Ref. AMM TASK 52-10-00-410-001).
   (3) Remove the access platform(s).
[Rev.10 from 2021] 2026.04.02 06:28:44 UTC