W DOC AIRBUS | AMM A320F

Detailed Inspection of Fuselage Lower Panel at NLG Bay Aft Corners, External Surface, LH/RH


TASK 53-11-00-210-005-A
Detailed Inspection of Fuselage Lower Panel at NLG Bay Aft Corners, External Surface, LH/RH


WARNING: BE CAREFUL WHEN YOU USE CONSUMABLE MATERIALS. OBEY THE MATERIAL MANUFACTURER'S INSTRUCTIONS AND YOUR LOCAL REGULATIONS.
ZONE: 100
1. Reason for the Job
Refer to the MPD TASK: 531112-01
DETAILED INSPECTION OF FUSELAGE LOWER PANEL AT NLG BAY AFT CORNERS, EXTERNAL SURFACE, LH/RH
NOTE: The effectivity of this task is "ALL". To know if this task is applicable for your aircraft, refer to the MPD task applicability and the weight variant data given in the SRM introduction.
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
AR
ACCESS PLATFORM 1M (3 FT)-ADJUSTABLE
 B. Consumable Materials
REFERENCE
DESIGNATION
(Material No.08BAA9)
Non Aqueous Cleaner-General - -
(Material No.14SBA1)
Textile-Lint free Cotton -
 C. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
100
LOWER HALF FUSELAGE INCLUDING RADOME
 D. Referenced Information
REFERENCE
DESIGNATION
SRM 51110001
(for corrective action)
SRM 51220001
(for corrective action)
3. Job Set-up
Subtask 53-11-00-941-089-A
A. Get Access
   (1) Put an ACCESS PLATFORM 1M (3 FT)-ADJUSTABLE in position at the zone 120.
Subtask 53-11-00-110-057-A
B. Cleaning of the Structure
   (1) Clean the inspection area with Non Aqueous Cleaner-General - - (Material No.08BAA9) and a lint-free cotton cloth Textile-Lint free Cotton - (Material No.14SBA1) , if necessary.
4. Procedure
Subtask 53-11-00-220-070-A
A. Inspection
   (1) Do a detailed inspection of the fuselage lower panel at the aft corners of the nose landing-gear well, external surface.
   (2) Make sure that there is no:
     (a) corrosion damage:
- If you find corrosion damage, refer to the Structural Repair Manual SRM 51220001 for types, inspection, removal and corrosion protection.
     (b) other damage (scratches, cracks, gouges, dents, creases):
- If you find other damage, refer to the Structural Repair Manual SRM 51110001 for damage classification and corrective action.
5. Close-up
Subtask 53-11-00-942-097-A
A. Close Access
   (1) Make sure that the work area is clean and clear of tools and other items.
   (2) Remove the access platform(s).