Detailed Inspection of NLG Aft Door Aft Fittings, LH/RH
TASK 52-82-00-220-801-A
Detailed Inspection of NLG Aft Door Aft Fittings, LH/RH
Refer to the MPD TASK: 528223-01
DETAILED INSPECTION OF NLG AFT DOOR AFT FITTINGS, LH/RH
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Consumable Materials
C. Work Zones and Access Panels
D. Referenced Information
3. Job Set-up
Subtask 52-82-00-010-053-A
Subtask 52-82-00-220-052-A
Subtask 52-82-00-942-052-A
[Rev.10 from 2021]
2026.04.02 06:28:39 UTC
Detailed Inspection of NLG Aft Door Aft Fittings, LH/RH
WARNING:
PUT THE SAFETY DEVICES AND THE WARNING NOTICES IN POSITION BEFORE YOU START A TASK ON OR NEAR:
- THE FLIGHT CONTROLS
- THE FLIGHT CONTROL SURFACES
- THE LANDING GEAR AND THE RELATED DOORS
- COMPONENTS THAT MOVE.
WARNING:
BE CAREFUL WHEN YOU USE CONSUMABLE MATERIALS. OBEY THE MATERIAL MANUFACTURER'S INSTRUCTIONS AND YOUR LOCAL REGULATIONS.
1. Reason for the JobRefer to the MPD TASK: 528223-01
DETAILED INSPECTION OF NLG AFT DOOR AFT FITTINGS, LH/RH
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 1 | ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE |
| REFERENCE | DESIGNATION |
|---|---|
| (Material No.08BAA9) | Non Aqueous Cleaner-General - - |
| (Material No.14SBA1) | Textile-Lint free Cotton - |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 715 | AFT DOORS |
| 716 | AFT DOORS |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 32-22-00-010-001-A | Nose Gear Doors - Ground Doors Opening |
| TASK 32-22-00-410-001-A | Nose Gear Doors - Ground Doors Closing |
| SRM 511100 | (for corrective action) |
| SRM 512200 | (for corrective action) |
Subtask 52-82-00-010-053-A
A. Get Access
(1) Put an ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE in position at zones 715 and 716.
(2) Open the nose landing-gear doors (Ref. AMM TASK 32-22-00-010-001).
Subtask 52-82-00-110-052-A (1) Put an ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE in position at zones 715 and 716.
(2) Open the nose landing-gear doors (Ref. AMM TASK 32-22-00-010-001).
B. Prepare the Inspection Area
(1) Make sure that the inspection area is sufficiently clean to do a satisfactory inspection of the area.
(2) If necessary, clean the inspection area with Non Aqueous Cleaner-General - - (Material No.08BAA9) and lint-free cotton cloth Textile-Lint free Cotton - (Material No.14SBA1) .
4. Procedure(1) Make sure that the inspection area is sufficiently clean to do a satisfactory inspection of the area.
(2) If necessary, clean the inspection area with Non Aqueous Cleaner-General - - (Material No.08BAA9) and lint-free cotton cloth Textile-Lint free Cotton - (Material No.14SBA1) .
Subtask 52-82-00-220-052-A
A. Inspection
(1) Do a detailed inspection of the aft fittings of the aft nose landing gear doors.
(2) Make sure that there is no:
(a) Corrosion damage :
5. Close-up(1) Do a detailed inspection of the aft fittings of the aft nose landing gear doors.
(2) Make sure that there is no:
(a) Corrosion damage :
- If you find corrosion damage, refer to the Structural Repair Manual SRM 512200 for corrosion types, inspection, removal and subsequent corrosion protection.
- If you find this type of damage, refer to the Structural Repair Manual SRM 511100 for the damage types, classification and corrective action.
Subtask 52-82-00-942-052-A
A. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Close the nose landing-gear doors (Ref. AMM TASK 32-22-00-410-001).
(3) Remove the ground support and maintenance equipment, the special and standard tools and all other items.
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Close the nose landing-gear doors (Ref. AMM TASK 32-22-00-410-001).
(3) Remove the ground support and maintenance equipment, the special and standard tools and all other items.