Installation of the CABIN PRESSURE Warning-Light Panel of the Emergency Exits
TASK 52-73-22-400-003-A
Installation of the CABIN PRESSURE Warning-Light Panel of the Emergency Exits
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Consumable Materials
C. Work Zones and Access Panels
D. Expendable Parts
E. Referenced Information
3. Job Set-up
Subtask 52-73-22-860-050-A ** ON A/C NOT FOR ALL
Subtask 52-73-22-420-056-A ** ON A/C NOT FOR ALL
Subtask 52-73-22-410-054-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.01 01:49:10 UTC
Installation of the CABIN PRESSURE Warning-Light Panel of the Emergency Exits
WARNING:
BE CAREFUL WHEN YOU USE CONSUMABLE MATERIALS. OBEY THE MATERIAL MANUFACTURER'S INSTRUCTIONS AND YOUR LOCAL REGULATIONS.
1. Reason for the JobSelf explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | ACCESS PLATFORM 5M (16 FT)- ADJUSTABLE |
| REFERENCE | DESIGNATION |
|---|---|
| (Material No.14SBA1) | Textile-Lint free Cotton - |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 832 | AFT PASSENGER/CREW DOOR |
| 834 | EMERGENCY EXITS |
| 835 | MID PASSENGER/CREW DOOR |
| 842 | AFT PASSENGER/CREW DOOR |
| 844 | EMERGENCY EXITS |
| 845 | MID PASSENGER/CREW DOOR |
| 835, 845 | |
| 833, 834, 843, 844 | |
| FOR [2WN1] (IND LT-SLIDE ARMED, L EMER EXIT) | |
| 834CZ | |
| FOR [2WN2] (IND LT-SLIDE ARMED, R EMER EXIT) | |
| 844CZ | |
| FOR [20WN1] (WARN LT PNL-CABIN PRESSURE, AFT L EMERGENCY EXIT) | |
| 834CZ | |
| FOR [20WN2] (WARN LT PNL-CABIN PRESSURE, AFT R EMERGENCY EXIT) | |
| 844CZ | |
| FOR [21WN1] (IND LT-SLIDE ARMED, FWD L EMERGENCY EXIT) | |
| 833CZ | |
| FOR [21WN2] (IND LT-SLIDE ARMED, FWD R EMERGENCY EXIT) | |
| 843CZ | |
| FIG.ITEM | DESIGNATION | IPC-CSN |
|---|---|---|
| 3 | LAMPS | AIPC 52-73-22-01-030 |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 24-41-00-861-002-A | Energize the Aircraft Electrical Circuits from the External Power |
| TASK 24-41-00-861-002-A-01 | Energize the Aircraft Electrical Circuits from the APU |
| TASK 24-41-00-861-002-A-02 | Energize the Aircraft Electrical Circuits from Engine 1(2) |
| TASK 24-41-00-862-002-A | De-energize the Aircraft Electrical Circuits Supplied from the External Power |
| TASK 24-41-00-862-002-A-01 | De-energize the Aircraft Electrical Circuits Supplied from the APU |
| TASK 24-41-00-862-002-A-02 | De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2) |
| TASK 25-23-47-400-013-A | Installation of the Door Linings of the RH FWD Emergency Exit Door at zone 251, or RH AFT at zone 252, or LH AFT at zone 232. |
| TASK 25-23-47-400-802-A | Installation of the Door Linings of the Emergency Exit, zones 251/252 |
| TASK 52-22-00-410-002-A | Closing of the Emergency Exit Doors from the Outside |
| TASK 52-73-00-710-004-A | Operational Test of the Cabin Overpressure Warning-System |
Subtask 52-73-22-860-050-A ** ON A/C NOT FOR ALL
A. Aircraft Maintenance Configuration
(1) Make sure that the ACCESS PLATFORM 5M (16 FT)- ADJUSTABLE is in position at applicable emergency exit 833 or 834 or 843 or 844.
(2) Make sure that the aircraft electrical circuits are energized.
(Ref. AMM TASK 24-41-00-861-002).
Subtask 52-73-22-860-050-B ** ON A/C NOT FOR ALL (1) Make sure that the ACCESS PLATFORM 5M (16 FT)- ADJUSTABLE is in position at applicable emergency exit 833 or 834 or 843 or 844.
(2) Make sure that the aircraft electrical circuits are energized.
(Ref. AMM TASK 24-41-00-861-002).
A. Aircraft Maintenance Configuration
(1) Make sure that the ACCESS PLATFORM 5M (16 FT)- ADJUSTABLE is in position at applicable emergency exit 835 or 845.
(2) Make sure that the aircraft electrical circuits are energized.
(Ref. AMM TASK 24-41-00-861-002).
Subtask 52-73-22-865-057-A ** ON A/C NOT FOR ALL (1) Make sure that the ACCESS PLATFORM 5M (16 FT)- ADJUSTABLE is in position at applicable emergency exit 835 or 845.
(2) Make sure that the aircraft electrical circuits are energized.
(Ref. AMM TASK 24-41-00-861-002).
B. Make sure that this(these) circuit breaker(s) is(are) open, safetied and tagged:
4. Procedure| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 121VU | EIS/SLIDES/ARM AND WARN/FLT | 15WN | P11 |
| 121VU | EIS/SLIDES/ARM AND WARN/GND | 13WN | P10 |
| 121VU | EIS/SDAC1 AND 2/DOOR/DET/PAX | 48WV | P05 |
Subtask 52-73-22-420-056-A ** ON A/C NOT FOR ALL
A. Installation of the Lamps
(2) Install the lens (4) on the CABIN PRESSURE warning-light panel (1).
Subtask 52-73-22-420-053-A ** ON A/C NOT FOR ALL CAUTION:
DO NOT TOUCH THE LAMP GLASS WITH YOUR FINGERS. THE OILS FROM YOUR SKIN WILL QUICKLY CAUSE DETERIORATION OF THE LAMP. IF YOU ACCIDENTALLY TOUCH THE LAMP GLASS, CLEAN IT WITH A LINT- FREE CLOTH. IF NECESSARY, MAKE THE CLOTH MOIST WITH WATER. DRY WITH LOW-PRESSURE COMPRESSED AIR JET. DO NOT USE ALCOHOL.
(1) Use the Textile-Lint free Cotton - (Material No.14SBA1) , and put the AIPC 52-73-22-01-030 LAMPS (3) in position on the CABIN PRESSURE warning-light panel (1). (2) Install the lens (4) on the CABIN PRESSURE warning-light panel (1).
B. Installation of the CABIN PRESSURE Warning-Light Panel
(1) Install the CABIN PRESSURE warning-light panel (1) on its support.
(2) Remove the CAP-BLANKING from each electrical connector and receptacle.
(3) Connect the electrical connector (6) to the electrical connector (5).
Subtask 52-73-22-865-058-A ** ON A/C NOT FOR ALL (1) Install the CABIN PRESSURE warning-light panel (1) on its support.
(2) Remove the CAP-BLANKING from each electrical connector and receptacle.
(3) Connect the electrical connector (6) to the electrical connector (5).
C. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
Subtask 52-73-22-410-055-A ** ON A/C NOT FOR ALL | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 121VU | EIS/SLIDES/ARM AND WARN/FLT | 15WN | P11 |
| 121VU | EIS/SLIDES/ARM AND WARN/GND | 13WN | P10 |
| 121VU | EIS/SDAC1 AND 2/DOOR/DET/PAX | 48WV | P05 |
D. Installation of the Lining Panels of the Emergency Exit
(1) Install the lining panels (Ref. AMM TASK 25-23-47-400-013):
(a) FOR [2WN1] (IND LT-SLIDE ARMED, L EMER EXIT)
Subtask 52-73-22-410-055-B ** ON A/C NOT FOR ALL (1) Install the lining panels (Ref. AMM TASK 25-23-47-400-013):
(a) FOR [2WN1] (IND LT-SLIDE ARMED, L EMER EXIT)
- Lining panel 834CZ.
- Lining panel 844CZ.
- Lining panel 833CZ.
- Lining panel 843CZ.
D. Installation of the Lining Panels of the Emergency Exit
(1) Install the lining panels (Ref. AMM TASK 25-23-47-400-802):
(a) FOR [20WN1] (WARN LT PNL-CABIN PRESSURE, AFT L EMERGENCY EXIT)
Subtask 52-73-22-710-050-A ** ON A/C NOT FOR ALL (1) Install the lining panels (Ref. AMM TASK 25-23-47-400-802):
(a) FOR [20WN1] (WARN LT PNL-CABIN PRESSURE, AFT L EMERGENCY EXIT)
- Lining panel 834CZ.
- Lining panel 844CZ.
E. Operational Test of the Cabin Overpressure Warning-System
(1) Do an operational test of the cabin overpressure warning-system (Ref. AMM TASK 52-73-00-710-004).
5. Close-up(1) Do an operational test of the cabin overpressure warning-system (Ref. AMM TASK 52-73-00-710-004).
Subtask 52-73-22-410-054-A ** ON A/C NOT FOR ALL
A. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Close applicable emergency exit 833 or 843 or 834 or 844 (Ref. AMM TASK 52-22-00-410-002).
(3) Remove the access platform(s).
Subtask 52-73-22-410-054-B ** ON A/C NOT FOR ALL (1) Make sure that the work area is clean and clear of tools and other items.
(2) Close applicable emergency exit 833 or 843 or 834 or 844 (Ref. AMM TASK 52-22-00-410-002).
(3) Remove the access platform(s).
A. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Close applicable emergency exit 835 or (Ref. AMM TASK 52-22-00-410-002) 845.
(3) Remove the access platform(s).
Subtask 52-73-22-862-050-A ** ON A/C NOT FOR ALL (1) Make sure that the work area is clean and clear of tools and other items.
(2) Close applicable emergency exit 835 or (Ref. AMM TASK 52-22-00-410-002) 845.
(3) Remove the access platform(s).
Emergency Exits - CABIN PRESSURE Warning-Light Panel