Installation of the SLIDE ARMED Indicator Light of the Aft Emergency Exits
TASK 52-73-21-400-003-E
Installation of the SLIDE ARMED Indicator Light of the Aft Emergency Exits
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 52-73-21-860-060-A ** ON A/C NOT FOR ALL
Subtask 52-73-21-420-060-A ** ON A/C NOT FOR ALL
Subtask 52-73-21-420-061-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.01 01:49:01 UTC
Installation of the SLIDE ARMED Indicator Light of the Aft Emergency Exits
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | ACCESS PLATFORM 5M (16 FT)- ADJUSTABLE |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 835 | MID PASSENGER/CREW DOOR |
| 845 | MID PASSENGER/CREW DOOR |
| 835, 845 | |
| FOR [2WN1] (IND LT-SLIDE ARMED, L EMER EXIT) | |
| 835CZ | |
| FOR [2WN2] (IND LT-SLIDE ARMED, R EMER EXIT) | |
| 845CZ | |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 24-41-00-861-002-A | Energize the Aircraft Electrical Circuits from the External Power |
| TASK 24-41-00-861-002-A-01 | Energize the Aircraft Electrical Circuits from the APU |
| TASK 24-41-00-861-002-A-02 | Energize the Aircraft Electrical Circuits from Engine 1(2) |
| TASK 24-41-00-862-002-A | De-energize the Aircraft Electrical Circuits Supplied from the External Power |
| TASK 24-41-00-862-002-A-01 | De-energize the Aircraft Electrical Circuits Supplied from the APU |
| TASK 24-41-00-862-002-A-02 | De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2) |
| TASK 25-23-47-400-802-A | Installation of the Door Linings of the Emergency Exit, zones 251/252 |
| TASK 52-22-00-410-002-A | Closing of the Emergency Exit Doors from the Outside |
| TASK 52-73-00-710-002-E | Operational Test of the Warning System Related to the Emergency Exit Doors |
Subtask 52-73-21-860-060-A ** ON A/C NOT FOR ALL
A. Aircraft Maintenance Configuration
(1) Make sure that the ACCESS PLATFORM 5M (16 FT)- ADJUSTABLE is in position at applicable emergency exit 835 or 845.
(2) Make sure that the aircraft electrical circuits are energized.
(Ref. AMM TASK 24-41-00-861-002).
Subtask 52-73-21-865-069-A ** ON A/C NOT FOR ALL (1) Make sure that the ACCESS PLATFORM 5M (16 FT)- ADJUSTABLE is in position at applicable emergency exit 835 or 845.
(2) Make sure that the aircraft electrical circuits are energized.
(Ref. AMM TASK 24-41-00-861-002).
B. Make sure that this(these) circuit breaker(s) is(are) open, safetied and tagged:
4. Procedure| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 121VU | EIS/SLIDES/ARM AND WARN/FLT | 15WN | P11 |
| 121VU | EIS/SLIDES/ARM AND WARN/GND | 13WN | P10 |
| 121VU | EIS/SDAC1 AND 2/DOOR/DET/PAX | 48WV | P05 |
Subtask 52-73-21-420-060-A ** ON A/C NOT FOR ALL
A. Installation of the SLIDE ARMED Indicator Light
(1) Install the SLIDE ARMED indicator light (2) on its support.
(2) Remove the CAP-BLANKING from each electrical connector and receptacle.
(3) Connect the electrical connector (3) to the electrical connector (4).
Subtask 52-73-21-865-070-A ** ON A/C NOT FOR ALL (1) Install the SLIDE ARMED indicator light (2) on its support.
(2) Remove the CAP-BLANKING from each electrical connector and receptacle.
(3) Connect the electrical connector (3) to the electrical connector (4).
B. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
Subtask 52-73-21-710-056-A ** ON A/C NOT FOR ALL | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 121VU | EIS/SLIDES/ARM AND WARN/FLT | 15WN | P11 |
| 121VU | EIS/SLIDES/ARM AND WARN/GND | 13WN | P10 |
| 121VU | EIS/SDAC1 AND 2/DOOR/DET/PAX | 48WV | P05 |
C. Operational Test
(1) Do an operational test of the SLIDE ARMED indicator light of the emergency exit (Ref. AMM TASK 52-73-00-710-002).
5. Close-up(1) Do an operational test of the SLIDE ARMED indicator light of the emergency exit (Ref. AMM TASK 52-73-00-710-002).
Subtask 52-73-21-420-061-A ** ON A/C NOT FOR ALL
A. Installation of the Door Lining Panel
(1) Install the insulation.
(2) Install the removed door lining panel (Ref. AMM TASK 25-23-47-400-802):
(a) FOR [2WN1] (IND LT-SLIDE ARMED, L EMER EXIT)
Subtask 52-73-21-410-062-A ** ON A/C NOT FOR ALL (1) Install the insulation.
(2) Install the removed door lining panel (Ref. AMM TASK 25-23-47-400-802):
(a) FOR [2WN1] (IND LT-SLIDE ARMED, L EMER EXIT)
- Lining panel 835CZ.
- Lining panel 845CZ.
B. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Close applicable emergency exit 835 or 845 (Ref. AMM TASK 52-22-00-410-002).
(3) Remove the access platform(s).
Subtask 52-73-21-862-051-A ** ON A/C NOT FOR ALL (1) Make sure that the work area is clean and clear of tools and other items.
(2) Close applicable emergency exit 835 or 845 (Ref. AMM TASK 52-22-00-410-002).
(3) Remove the access platform(s).
Aft Emergency Exits - SLIDE ARMED Indicator Light