W DOC AIRBUS | AMM A320F

Installation of the SLIDE ARMED Indicator-Light of the Emergency Exit


TASK 52-73-21-400-003-A
Installation of the SLIDE ARMED Indicator-Light of the Emergency Exit


ZONE: 832
ZONE: 842
FIN: 2WN1 ** ON A/C NOT FOR ALL
FIN: 2WN2 ** ON A/C NOT FOR ALL
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
1
WRENCH - SPANNER
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
832
AFT PASSENGER/CREW DOOR
842
AFT PASSENGER/CREW DOOR
831, 841
 C. Referenced Information
REFERENCE
DESIGNATION
TASK 24-42-00-861-001-A
Energize the Ground Service Network from the External Power
TASK 52-10-00-410-001-A
Closing of the Passenger/Crew Door
TASK 52-73-00-710-002-A
Operational Test of the Warning System Related to the Emergency Exit Doors
3. Job Set-up
Subtask 52-73-21-860-056-A ** ON A/C NOT FOR ALL
A. Aircraft Maintenance Configuration
   (1) Make sure that the access platform is in position.
   (2) Make sure that the ground service network is energized (Ref. AMM TASK 24-42-00-861-001).
Subtask 52-73-21-865-057-A ** ON A/C NOT FOR ALL
B. Make sure that this(these) circuit breaker(s) is(are) open, safetied and tagged:
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
121VUEIS/SLIDES/ARM AND WARN/FLT15WNP11
121VUEIS/SLIDES/ARM AND WARN/GND13WNP10
121VUEIS/SDAC1 AND 2/DOOR/DET/PAX48WVP05
4. Procedure
Subtask 52-73-21-420-052-A ** ON A/C NOT FOR ALL
A. Installation of the SLIDE ARMED Indicator-Light
   (1) Install the SLIDE ARMED indicator-light (2) on the lining panel (7).
   (2) Remove the CAP-BLANKING from each electrical connector and receptacle.
   (3) Connect the electrical connector (3) to the electrical receptacle (4).
Subtask 52-73-21-410-054-A ** ON A/C NOT FOR ALL
B. Installation of the Lining Panel
   (1) Install the insulation.
   (2) Install the lining panel.
     (a) FOR [2WN1] (IND LT-SLIDE ARMED, L EMER EXIT)
241LW.
     (b) FOR [2WN2] (IND LT-SLIDE ARMED, R EMER EXIT)
242LW.
Subtask 52-73-21-865-058-A ** ON A/C NOT FOR ALL
C. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
121VUEIS/SLIDES/ARM AND WARN/FLT15WNP11
121VUEIS/SLIDES/ARM AND WARN/GND13WNP10
121VUEIS/SDAC1 AND 2/DOOR/DET/PAX48WVP05
Subtask 52-73-21-710-052-A ** ON A/C NOT FOR ALL
D. Operational Test
   (1) Do an operational test of the SLIDE ARMED indicator-light of the emergency exit hatches. (Ref. AMM TASK 52-73-00-710-002)
5. Close-up
Subtask 52-73-21-420-056-A ** ON A/C NOT FOR ALL
A. Arming of the Emergency Escape Slide
   (1) Arm the escape slide of the emergency exit (7) as follows:
     (a) With the WRENCH - SPANNER turn the head of the latch pin (6) a quarter turn clockwise to extend the latch pin (6).
NOTE: The SLIDE ARMED (2) indicator-light comes on.
     (b) Install and close the flap (5) on the emergency exit (7).
NOTE: The SLIDE ARMED (2) indicator-light goes off.
Subtask 52-73-21-410-055-A ** ON A/C NOT FOR ALL
B. Close Access
   (1) Make sure that the work area is clean and clear of tools and other items.
   (2) Close the applicable FWD passenger/crew door 831 or 841 (Ref. AMM TASK 52-10-00-410-001)
   (3) Remove the access platform(s).
[Rev.10 from 2021] 2026.04.01 01:48:57 UTC