Removal of the SLIDE ARMED Indicator-Light of the Emergency Exit
TASK 52-73-21-000-003-B
Removal of the SLIDE ARMED Indicator-Light of the Emergency Exit
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 52-73-21-861-050-A ** ON A/C NOT FOR ALL
Subtask 52-73-21-020-057-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.02 06:28:36 UTC
Removal of the SLIDE ARMED Indicator-Light of the Emergency Exit
ZONE: 832
ZONE: 833
ZONE: 842
ZONE: 843
FIN: 2WN1 ** ON A/C NOT FOR ALL
FIN: 2WN2 ** ON A/C NOT FOR ALL
FIN: 21WN1 ** ON A/C NOT FOR ALL
FIN: 21WN2 ** ON A/C NOT FOR ALL
1. Reason for the JobZONE: 833
ZONE: 842
ZONE: 843
FIN: 2WN1 ** ON A/C NOT FOR ALL
FIN: 2WN2 ** ON A/C NOT FOR ALL
FIN: 21WN1 ** ON A/C NOT FOR ALL
FIN: 21WN2 ** ON A/C NOT FOR ALL
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | ACCESS PLATFORM 5M (16 FT)- ADJUSTABLE |
| No specific | AR | CAP - BLANKING |
| No specific | AR | SAFETY CLIP - CIRCUIT BREAKER |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 832 | AFT PASSENGER/CREW DOOR |
| 833 | EMERGENCY EXITS |
| 842 | AFT PASSENGER/CREW DOOR |
| 843 | EMERGENCY EXITS |
| 833, 834, 843, 844 | |
| FOR [2WN1] (IND LT-SLIDE ARMED, L EMER EXIT) | |
| 834CZ | |
| FOR [2WN2] (IND LT-SLIDE ARMED, R EMER EXIT) | |
| 844CZ | |
| FOR [21WN1] (IND LT-SLIDE ARMED, FWD L EMERGENCY EXIT) | |
| 833CZ | |
| FOR [21WN2] (IND LT-SLIDE ARMED, FWD R EMERGENCY EXIT) | |
| 843CZ | |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 24-42-00-861-001-A | Energize the Ground Service Network from the External Power |
| TASK 52-22-00-010-002-A | Opening of the Emergency Exit Doors from the Outside |
Subtask 52-73-21-861-050-A ** ON A/C NOT FOR ALL
A. Aircraft Maintenance Configuration
(1) Energize the ground service network
(Ref. AMM TASK 24-42-00-861-001).
Subtask 52-73-21-865-059-A ** ON A/C NOT FOR ALL (1) Energize the ground service network
(Ref. AMM TASK 24-42-00-861-001).
B. Open, safety and tag this(these) circuit breaker(s):
Subtask 52-73-21-010-056-A ** ON A/C NOT FOR ALL | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 121VU | EIS/SLIDES/ARM AND WARN/FLT | 15WN | P11 |
| 121VU | EIS/SLIDES/ARM AND WARN/GND | 13WN | P10 |
| 121VU | EIS/SDAC1 AND 2/DOOR/DET/PAX | 48WV | P05 |
C. Get Access
(2) Open the applicable emergency exit (Ref. AMM TASK 52-22-00-010-002).
Subtask 52-73-21-010-059-A ** ON A/C NOT FOR ALL WARNING:
BEFORE YOU START WORK ON THE DOOR, MAKE SURE THAT:
- THE EMERGENCY CONTROL HANDLE IS IN THE DISARMED POSITION WITH THE SAFETY PIN INSTALLED.
- THE PERCUSSION LEVER OF THE DOOR-DAMPER AND EMERGENCY-OPERATION CYLINDER IS IN THE DISARMED POSITION WITH THE SAFETY PIN INSTALLED.
WARNING:
STOP THE OPENING PROCEDURE IF THE RED WARNING LIGHT FLASHES. IF THE RED WARNING LIGHT FLASHES, REMAINING PRESSURE CAN CAUSE THE DOOR TO OPEN SUDDENLY AND CAN:
(1) Put an ACCESS PLATFORM 5M (16 FT)- ADJUSTABLE in position at the applicable emergency exit 833 or 834 or 843 or 844. - KILL OR CAUSE SERIOUS INJURY TO PERSONS
- CAUSE DAMAGE TO THE AIRCRAFT.
(2) Open the applicable emergency exit (Ref. AMM TASK 52-22-00-010-002).
D. Removal of the Door Lining Panels
(1) Remove the door lining panels
(a) FOR [2WN1] (IND LT-SLIDE ARMED, L EMER EXIT)
834CZ.
(b) FOR [2WN2] (IND LT-SLIDE ARMED, R EMER EXIT)
844CZ.
(c) FOR [21WN1] (IND LT-SLIDE ARMED, FWD L EMERGENCY EXIT)
833CZ.
(d) FOR [21WN2] (IND LT-SLIDE ARMED, FWD R EMERGENCY EXIT)
843CZ.
4. Procedure(1) Remove the door lining panels
(a) FOR [2WN1] (IND LT-SLIDE ARMED, L EMER EXIT)
834CZ.
(b) FOR [2WN2] (IND LT-SLIDE ARMED, R EMER EXIT)
844CZ.
(c) FOR [21WN1] (IND LT-SLIDE ARMED, FWD L EMERGENCY EXIT)
833CZ.
(d) FOR [21WN2] (IND LT-SLIDE ARMED, FWD R EMERGENCY EXIT)
843CZ.
Subtask 52-73-21-020-057-A ** ON A/C NOT FOR ALL
A. Removal the SLIDE ARMED Indicator-Light
(1) Disconnect the electrical connector (3) from the electrical connector (4).
(2) Push the tabs (1) of the SLIDE ARMED indicator-light (2).
(3) Remove the SLIDE ARMED indicator-light (2) from its support.
(4) Put the CAP-BLANKING on each disconnected electrical connector and receptacle.
(1) Disconnect the electrical connector (3) from the electrical connector (4).
(2) Push the tabs (1) of the SLIDE ARMED indicator-light (2).
(3) Remove the SLIDE ARMED indicator-light (2) from its support.
(4) Put the CAP-BLANKING on each disconnected electrical connector and receptacle.
SLIDE ARMED Indicator-Light of the Emergency Exit