Installation of the Proximity Switches of the Aft Emergency Exits
TASK 52-73-11-400-004-B
Installation of the Proximity Switches of the Aft Emergency Exits
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Consumable Materials
C. Work Zones and Access Panels
D. Referenced Information
3. Job Set-up
Subtask 52-73-11-860-051-A ** ON A/C NOT FOR ALL
Subtask 52-73-11-420-065-A ** ON A/C NOT FOR ALL
Subtask 52-73-11-410-065-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.01 01:48:42 UTC
Installation of the Proximity Switches of the Aft Emergency Exits
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | Torque wrench: range to between 3.15 and 2.85 m.daN (23.23 and 21.02 lbf.ft ) ![]() |
| REFERENCE | DESIGNATION |
|---|---|
| (Material No.14QFB1) | Wire-Locking Dia: 0.8 mm CRES Nickel Alloy - |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 241 | CENTER PASSENGER COMPARTMENT |
| 242 | CENTER PASSENGER COMPARTMENT |
| 834, 844 | |
| FOR [6WN1] (PROX SW-HANDLE, L AFT EMER EXIT ESC SLIDE) | |
| 834CZ | |
| FOR [6WN2] (PROX SW-HANDLE, R AFT EMER EXIT ESC SLIDE) | |
| 844CZ | |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 24-42-00-861-001-A | Energize the Ground Service Network from the External Power |
| TASK 24-42-00-862-001-A | De-energize the Ground Service Network Supplied from the External Power |
| TASK 52-22-00-410-002-A | Closing of the Emergency Exit Doors from the Outside |
| TASK 52-22-00-860-004-A | Special Precaution after Maintenance on the Door Damper and Emergency Operation Cylinder |
| TASK 52-71-00-820-009-B | Adjustment of the Proximity Switches of the Emergency Exits with the Door Checking Tool |
| TASK 52-71-00-820-009-B-01 | Adjustment of the Proximity Switches of the Emergency Exit Doors with the ECAM Display Unit (DU) |
| TASK 52-73-00-710-002-B | Operational Test of the Warning System related to the Emergency Exits |
| FOR [6WN1] (PROX SW-HANDLE, L AFT EMER EXIT ESC SLIDE) | |
| TASK 25-23-47-400-013-A | Installation of the Door Linings of the RH FWD Emergency Exit Door at zone 251, or RH AFT at zone 252, or LH AFT at zone 232. |
| FOR [6WN2] (PROX SW-HANDLE, R AFT EMER EXIT ESC SLIDE) | |
| TASK 25-23-47-400-013-A | Installation of the Door Linings of the RH FWD Emergency Exit Door at zone 251, or RH AFT at zone 252, or LH AFT at zone 232. |
Subtask 52-73-11-860-051-A ** ON A/C NOT FOR ALL
A. Aircraft Maintenance Configuration
(1) Make sure that the ground service network is emergized (Ref. AMM TASK 24-42-00-861-001).
(2) Make sure that the access platform is in position.
Subtask 52-73-11-865-069-A ** ON A/C NOT FOR ALL (1) Make sure that the ground service network is emergized (Ref. AMM TASK 24-42-00-861-001).
(2) Make sure that the access platform is in position.
B. Make sure that this(these) circuit breaker(s) is(are) open, safetied and tagged:
4. Procedure| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 121VU | EIS/SLIDES/ARM AND WARN/FLT | 15WN | P11 |
| 121VU | EIS/SLIDES/ARM AND WARN/GND | 13WN | P10 |
| 121VU | EIS/SDAC1 AND 2/DOOR/DET/PAX | 48WV | P05 |
Subtask 52-73-11-420-065-A ** ON A/C NOT FOR ALL
A. Installation of the Proximity Switch
(1) Install the proximity switch (2) on its support.
(2) Install the washer (3) and the nut (4).
(3) TORQUE the nut (4) to between 3.15 and 2.85 m.daN (23.23 and 21.02 lbf.ft )
.
(4) Safety the nut (4) and the washer (3) with14QFB1 Wire-Locking Dia: 0.8 mm CRES Nickel Alloy - .
(5) Remove the blanking cap from the electrical connector (1).
(6) Connect the electrical connector (1) to the proximity switch (2).
(7) Adjust the proximity switch (2) (Ref. AMM TASK 52-71-00-820-009).
Subtask 52-73-11-865-070-A ** ON A/C NOT FOR ALL (1) Install the proximity switch (2) on its support.
(2) Install the washer (3) and the nut (4).
(3) TORQUE the nut (4) to between 3.15 and 2.85 m.daN (23.23 and 21.02 lbf.ft )
. (4) Safety the nut (4) and the washer (3) with
(5) Remove the blanking cap from the electrical connector (1).
(6) Connect the electrical connector (1) to the proximity switch (2).
(7) Adjust the proximity switch (2) (Ref. AMM TASK 52-71-00-820-009).
B. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
Subtask 52-73-11-710-051-A ** ON A/C NOT FOR ALL | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 121VU | EIS/SLIDES/ARM AND WARN/FLT | 15WN | P11 |
| 121VU | EIS/SLIDES/ARM AND WARN/GND | 13WN | P10 |
| 121VU | EIS/SDAC1 AND 2/DOOR/DET/PAX | 48WV | P05 |
C. Operational Test
(1) Do an operational test of the warning system of the emergency exits (Ref. AMM TASK 52-73-00-710-002).
5. Close-up(1) Do an operational test of the warning system of the emergency exits (Ref. AMM TASK 52-73-00-710-002).
Subtask 52-73-11-410-065-A ** ON A/C NOT FOR ALL
A. Installation of the Lining Panel
(1) Install the insulation blanket.
(2) Install the lining panel:
(a) FOR [6WN1] (PROX SW-HANDLE, L AFT EMER EXIT ESC SLIDE)
834CZ (Ref. AMM TASK 25-23-47-400-013).
(b) FOR [6WN2] (PROX SW-HANDLE, R AFT EMER EXIT ESC SLIDE)
844CZ (Ref. AMM TASK 25-23-47-400-013).
Subtask 52-73-11-410-057-A ** ON A/C NOT FOR ALL (1) Install the insulation blanket.
(2) Install the lining panel:
(a) FOR [6WN1] (PROX SW-HANDLE, L AFT EMER EXIT ESC SLIDE)
834CZ (Ref. AMM TASK 25-23-47-400-013).
(b) FOR [6WN2] (PROX SW-HANDLE, R AFT EMER EXIT ESC SLIDE)
844CZ (Ref. AMM TASK 25-23-47-400-013).
B. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Obey the special precautions after you do work on the emergency exit (Ref. AMM TASK 52-22-00-860-004).
(3) Close the applicable emergency exit door 834 or 844 (Ref. AMM TASK 52-22-00-410-002).
(4) Remove the access platform(s).
Subtask 52-73-11-862-058-A ** ON A/C NOT FOR ALL (1) Make sure that the work area is clean and clear of tools and other items.
(2) Obey the special precautions after you do work on the emergency exit (Ref. AMM TASK 52-22-00-860-004).
(3) Close the applicable emergency exit door 834 or 844 (Ref. AMM TASK 52-22-00-410-002).
(4) Remove the access platform(s).
Proximity Switches (6WN1, 6WN2) of the Aft Emergency Exits